Doppler color-flow imaging: Screening of a patent foramen ovale in children scheduled for neurosurgery in the silting position

被引:18
作者
Fuchs, G
Schwarz, G
Stein, J
Kaltenbock, F
Baumgartner, A
Oberbauer, RW
机构
[1] Graz Univ, Dept Anesthesiol & Intens Care Med, A-8036 Graz, Austria
[2] Graz Univ, Dept Pediat, A-8036 Graz, Austria
[3] Graz Univ, Dept Neurosurg, A-8036 Graz, Austria
关键词
doppler color-flow mapping; childhood; paradoxical air embolism; posterior fossa; sitting position;
D O I
10.1097/00008506-199801000-00002
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
A patent foramen ovale (PFO) is the most common cause of paradoxical air embolism during neurosurgical procedures in the posterior fossa in the sitting position in both adults and children. To detect right-to-left shunting, we performed Doppler color-flow imaging preoperatively in 30 children scheduled for neurosurgical procedures in the sitting position. A PFO was diagnosed on the basis of color alterations indicating an immediate blood shunt through a PFO. Six of 30 children (20%) had a PFO; in 4 of these children the sitting position then was avoided, and 2 children were operated on in a special supine position with minimal elevation of the head. Venous air embolism occurred in 9 of 24 (37%) children operated on in the sitting position and in none of the 6 children operated on in a nonsitting position. We conclude that Doppler color-flow mapping could be a useful noninvasive technique to screen children scheduled for neurosurgery in the sitting position for the presence of a PFO.
引用
收藏
页码:5 / 9
页数:5
相关论文
共 27 条
[1]  
ALBIN MS, 1991, ANESTH ANALG, V73, P346
[2]   ANESTHETIC MANAGEMENT OF POSTERIOR-FOSSA SURGERY IN SITTING POSITION [J].
ALBIN, MS ;
BABINSKI, M ;
MAROON, JC ;
JANNETTA, PJ .
ACTA ANAESTHESIOLOGICA SCANDINAVICA, 1976, 20 (02) :117-128
[3]   PARAMETERS AFFECTING OCCURRENCE OF PARADOXICAL AIR-EMBOLISM [J].
BLACK, S ;
CUCCHIARA, RF ;
NISHIMURA, RA ;
MICHENFELDER, JD .
ANESTHESIOLOGY, 1989, 71 (02) :235-241
[4]   DETECTION OF PATENT FORAMEN OVALE BY DOPPLER COLOR FLOW MAPPING IN PATIENTS UNDERGOING CARDIAC-CATHETERIZATION [J].
BRICKNER, ME ;
GRAYBURN, PA ;
FADEL, B ;
CARRY, MM ;
EICHHORN, EJ ;
LANGE, RA ;
TAYLOR, AL .
AMERICAN JOURNAL OF CARDIOLOGY, 1991, 68 (01) :125-129
[5]  
CHILD J S, 1990, Cardiology Clinics, V8, P289
[6]   FAILURE OF PREOPERATIVE ECHO TESTING TO PREVENT PARADOXICAL AIR-EMBOLISM - REPORT OF 2 CASES [J].
CUCCHIARA, RF ;
NISHIMURA, RA ;
BLACK, S .
ANESTHESIOLOGY, 1989, 71 (04) :604-607
[7]  
DASH HM, 1990, ANESTH ANALG, V70, pS78
[8]   TRANSESOPHAGEAL CONTRAST ECHOCARDIOGRAPHY AND COLOR FLOW MAPPING - METHODS OF CHOICE FOR THE DETECTION OF SHUNTS AT THE ATRIAL LEVEL [J].
DEBELDER, MA ;
TOURIKIS, L ;
GRIFFITH, M ;
LEECH, G ;
CAMM, AJ .
AMERICAN HEART JOURNAL, 1992, 124 (06) :1545-1550
[9]   THE INCIDENCE OF PATENT FORAMEN OVALE IN 1,000 CONSECUTIVE PATIENTS - A CONTRAST TRANSESOPHAGEAL ECHOCARDIOGRAPHY STUDY [J].
FISHER, DC ;
FISHER, EA ;
BUDD, JH ;
ROSEN, SE ;
GOLDMAN, ME .
CHEST, 1995, 107 (06) :1504-1509
[10]  
FOEX P, 1980, CIRCULATION ANAESTHE, P281