NON-ENHANCED PATTERN ON CONTRAST-ENHANCED ULTRASOUND IN THE LOCAL EFFICACY ASSESSMENT OF IRREVERSIBLE ELECTROPORATION ABLATION OF PANCREATIC ADENOCARCINOMA

被引:1
|
作者
Lin, Manxia [1 ]
Xie, Xiaoyan [1 ]
Xu, Ming [1 ]
Feng, Shiting [2 ]
Tian, Wenshuo [1 ]
Zhuang, Bowen [1 ]
Su, Liya [1 ]
Ye, Jieyi [1 ]
Lin, Jinhua [1 ]
Liang, Ping [3 ]
Yu, Jie [3 ]
Kuang, Ming [1 ,4 ]
机构
[1] Sun Yat Sen Univ, Div Intervent Ultrasound, Dept Med Ultrason, Affiliated Hosp 1,Inst Study Diagnost & Intervent, Guangzhou, Guangdong, Peoples R China
[2] Sun Yat Sen Univ, Dept Radiol, Affiliated Hosp 1, Guangzhou, Guangdong, Peoples R China
[3] Chinese Peoples Liberat Army Gen Hosp, Dept Intervent Ultrasound, Beijing, Peoples R China
[4] Sun Yat Sen Univ, Affiliated Hosp 1, Dept Liver Surg, Guangzhou, Guangdong, Peoples R China
关键词
Irreversible electroporation ablation; Contrast-enhanced ultrasound; Pancreatic adenocarcinoma; Imaging; Tumor response; PORCINE LIVER; US FINDINGS; TUMORS; CANCER; SAFETY; MRI;
D O I
10.1016/j.ultrasmedbio.2018.05.018
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
The objective was to evaluate the diagnostic value of contrast-enhanced ultrasound in the assessment of the local efficacy after irreversible electroporation (IRE) ablation of pancreatic adenocarcinoma 1 mo after ablation. Fifteen patients with pancreatic adenocarcinoma were treated with IRE and then examined by contrast-enhanced ultrasound 1 mo after ablation. The contrast agent was SonoVue. Technical efficacy was assessed at 3 mo after IRE and classified as technical efficiency (TE) and technical inefficiency (TIE). Diagnostic performance was analyzed using a receiver operating characteristic curve. Ten patients were considered as having TE, and five, TIE. Complete non-enhancement was observed in seven ablation zones (70.0%) in the TE group, and peripheral heterogeneous enhancement, in all five ablation zones (100.0%) in the TIE group. The non-enhancement pattern differed significantly between the TE and TIE groups (p = 0.026), with significant correlation with technical efficacy (p = 0.007). The area under the receiver operating characteristic curve was 0.85 (p = 0.008, 95% confidence interval: 0.65-1.05). A non-enhancement pattern using contrast-enhanced ultrasound was useful in the assessment of local efficacy after IRE ablation of pancreatic adenocarcinoma. (E-mail: kuangm@mail.sysu.edu.cn) (C) 2018 World Federation for Ultrasound in Medicine & Biology. All rights reserved.
引用
收藏
页码:1986 / 1995
页数:10
相关论文
共 50 条
  • [1] ULTRASOUND AND CONTRAST-ENHANCED ULTRASOUND FOR EVALUATION OF IRREVERSIBLE ELECTROPORATION ABLATION: IN VIVO PROOF OF CONCEPT IN NORMAL PORCINE LIVER
    Lin, Man-Xia
    Kuang, Ming
    Xu, Ming
    Zhuang, Bo-Wen
    Tian, Wen-Shuo
    Ye, Jie-Yi
    Xie, Xiao-Hua
    Xie, Xiao-Yan
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2016, 42 (11) : 2639 - 2649
  • [2] The role of contrast-enhanced endoscopic ultrasound in pancreatic adenocarcinoma
    Saftoiu, Adrian
    Vilmann, Peter
    Bhutani, Manoop S.
    ENDOSCOPIC ULTRASOUND, 2016, 5 (06) : 368 - 372
  • [3] Assessment of irreversible electroporation ablation zone using Kupffer-phase contrast-enhanced ultrasound images with Sonazoid
    Katsutoshi Sugimoto
    Fuminori Moriyasu
    Kobayashi Yoshiyuki
    Yasuharu Imai
    Journal of Medical Ultrasonics, 2014, 41 : 531 - 532
  • [4] Assessment of irreversible electroporation ablation zone using Kupffer-phase contrast-enhanced ultrasound images with Sonazoid
    Sugimoto, Katsutoshi
    Moriyasu, Fuminori
    Yoshiyuki, Kobayashi
    Imai, Yasuharu
    JOURNAL OF MEDICAL ULTRASONICS, 2014, 41 (04) : 531 - 532
  • [5] Efficacy of color Doppler ultrasound and contrast-enhanced ultrasound in identifying vascular invasion in pancreatic ductal adenocarcinoma
    Jia, Wan-Ying
    Gui, Yang
    Chen, Xue-Qi
    Tan, Li
    Zhang, Jing
    Xiao, Meng-Su
    Chang, Xiao-Yan
    Dai, Meng-Hua
    Guo, Jun-Chao
    Cheng, Yue-Juan
    Wang, Xiang
    Zhang, Jia-Hui
    Zhang, Xiao-Qian
    Lv, Ke
    INSIGHTS INTO IMAGING, 2024, 15 (01):
  • [6] Irreversible electroporation of hepatocellular carcinoma: preliminary report on the diagnostic accuracy of magnetic resonance, computer tomography, and contrast-enhanced ultrasound in evaluation of the ablated area
    Granata, Vincenza
    di Castelguidone, Elisabetta de Lutio
    Fusco, Roberta
    Catalano, Orlando
    Piccirillo, Mauro
    Palaia, Raffaele
    Izzo, Francesco
    Gallipoli, Adolfo D'Errico
    Petrillo, Antonella
    RADIOLOGIA MEDICA, 2016, 121 (02): : 122 - 131
  • [7] Irreversible electroporation in patients with liver tumours: treated-area patterns with contrast-enhanced ultrasound
    Zhou, Linyu
    Yin, Shanyu
    Chai, Weilu
    Zhao, Qiyu
    Tian, Guo
    Xu, Danxia
    Jiang, Tian'an
    WORLD JOURNAL OF SURGICAL ONCOLOGY, 2020, 18 (01)
  • [8] ULTRASOUND AND CONTRAST-ENHANCED ULTRASOUND FINDINGS AFTER PERCUTANEOUS IRREVERSIBLE ELECTROPORATION OF HEPATIC MALIGNANT TUMORS
    Chai, Weilu
    Xie, Liting
    Zhao, Qiyu
    Cheng, Chao
    Tian, Guo
    Jiang, Tian'an
    Wu, Pingping
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2020, 46 (03) : 620 - 629
  • [9] Percutaneous irreversible electroporation (IRE) of prostate cancer: Contrast-enhanced ultrasound (CEUS) findings
    Niessen, C.
    Jung, E. M.
    Beyer, L.
    Pregler, B.
    Dollinger, M.
    Haimerl, M.
    Scheer, F.
    Stroszczynski, C.
    Wiggermann, P.
    CLINICAL HEMORHEOLOGY AND MICROCIRCULATION, 2015, 61 (02) : 135 - 141
  • [10] Pancreatic Ductal Adenocarcinoma: The Characteristics of Contrast-Enhanced Ultrasound Are Correlated with the Hypoxic Microenvironment
    Wang, Lan
    Li, Ming
    Dong, Tiantian
    Li, Yuanyuan
    Yin, Ci
    Nie, Fang
    DIAGNOSTICS, 2023, 13 (20)