Virtual bronchoscopy for directing transbronchial needle aspiration of hilar and mediastinal lymph nodes: A pilot study

被引:117
作者
McAdams, HP
Goodman, PC
Kussin, P
机构
[1] Duke Univ, Med Ctr, Dept Radiol, Durham, NC 27710 USA
[2] Duke Univ, Med Ctr, Dept Med, Div Pulm & Crit Care Med, Durham, NC 27710 USA
关键词
D O I
10.2214/ajr.170.5.9574616
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. We conducted a preliminary investigation of virtual bronchoscopy as a guide fur transbronchial needle aspiration of hilar or mediastinal lymph nodes to assess the usefulness of this technique. CONCLUSION. Virtual bronchoscopic images derived from routine helical CT scans were useful for directing transbronchial needle aspiration in a clinical setting. In addition, virtual bronchoscopy may have been responsible for improving the yield of transbronchial needle aspirations done by our bronchoscopists when 22-gauge needles were used.
引用
收藏
页码:1361 / 1364
页数:4
相关论文
共 14 条
  • [1] ARROLIGA AC, 1993, CLIN CHEST MED, V14, P87
  • [2] TRANS-BRONCHIAL NEEDLE ASPIRATION IN THE PRACTICE OF BRONCHOSCOPY
    GAY, PC
    BRUTINEL, WM
    [J]. MAYO CLINIC PROCEEDINGS, 1989, 64 (02) : 158 - 162
  • [3] Three-dimensional helical CT of the tracheobronchial tree: Evaluation of imaging protocols and assessment of suspected stenoses with bronchoscopic correlation
    Kauczor, HU
    Wolcke, B
    Fischer, B
    Mildenberger, P
    Lorenz, J
    Thelen, M
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1996, 167 (02) : 419 - 424
  • [4] McAdams HP, 1996, INT CONGR SER, V1124, P73
  • [5] THE HIGH PRICE OF BRONCHOSCOPY - MAINTENANCE AND REPAIR OF THE FLEXIBLE FIBEROPTIC BRONCHOSCOPE
    MEHTA, AC
    CURTIS, PS
    SCALZITTI, ML
    MEEKER, DP
    [J]. CHEST, 1990, 98 (02) : 448 - 454
  • [6] PATTERSON GA, 1987, J THORAC CARDIOV SUR, V94, P679
  • [7] BRONCHOSCOPY IN NORTH-AMERICA - THE ACCP SURVEY
    PRAKASH, UBS
    OFFORD, KP
    STUBBS, SE
    [J]. CHEST, 1991, 100 (06) : 1668 - 1675
  • [8] Transthoracic needle biopsy of mediastinal lymph nodes for staging lung and other cancers
    Protopapas, Z
    Westcott, JL
    [J]. RADIOLOGY, 1996, 199 (02) : 489 - 496
  • [9] Perspective volume rendering of CT and MR images: Applications for endoscopic imaging
    Rubin, GD
    Beaulieu, CF
    Argiro, V
    Ringl, H
    Norbash, AM
    Feller, JF
    Dake, MD
    Jeffrey, RB
    Napel, S
    [J]. RADIOLOGY, 1996, 199 (02) : 321 - 330
  • [10] COMPARISON OF THE WANG 19-GAUGE AND 22-GAUGE NEEDLES IN THE MEDIASTINAL STAGING OF LUNG-CANCER
    SCHENK, DA
    CHAMBERS, SL
    DERDAK, S
    KOMADINA, KH
    PICKARD, JS
    STROLLO, PJ
    LEWIS, RE
    PATEFIELD, AJ
    HENDERSON, JH
    TOMSKI, SM
    MORALES, CF
    STERLING, JL
    SOLANKI, PH
    MOORE, J
    [J]. AMERICAN REVIEW OF RESPIRATORY DISEASE, 1993, 147 (05): : 1251 - 1258