Comparison of hook plate versus T-plate in the treatment of Neer type II distal clavicle fractures: a prospective matched comparative cohort study

被引:4
作者
Teimouri, Mehdi [1 ]
Ravanbod, Hadi [2 ]
Farrokhzad, Amirhosein [1 ]
Sabaghi, Jamal [1 ]
Mirghaderi, Seyed Peyman [3 ,4 ]
机构
[1] Isfahan Univ Med Sci, Ayatollah Kashani Hosp, Dept Orthoped Surg, Esfahan, Iran
[2] Isfahan Univ Med Sci, Al Zahra Hosp, Dept Orthoped Surg, Esfahan, Iran
[3] Univ Tehran Med Sci, Joint Reconstruct Res Ctr, Imam Khomeini Hosp Complex, Tehran, Iran
[4] Univ Tehran Med Sci, Students Sci Res Ctr SSRC, Tehran, Iran
关键词
Bone plates; Clavicle; Distal clavicle fracture; Hook plate; Internal fixators; T-plate; SURGICAL-TREATMENT; INTERNAL-FIXATION; UNSTABLE FRACTURES; LOCKING; OSTEOSYNTHESIS; 3RD;
D O I
10.1186/s13018-022-03261-8
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background This study aimed to compare the clinical and radiological outcomes of distal clavicle fracture fixation with a hook plate versus the standard non-locking T-plate for unstable Neer type II fractures. Methods A prospective matched cohort study including two groups of hook plates and T-plates fixation was conducted in our two tertiary trauma centers. Patients with distal clavicle fractures Neer type II were assessed for union and the Constant-Murley score (CMS) at 1-, 3-, and 6-month follow-ups. Inadequate radiographic consolidation > 6 months after surgery was defined as non-union. Subscales of CMSpain, CMSactivities of daily living, CMSrange of motion (ROM), and CMSstrength were also compared between groups. According to recommendations, the implant was removed after union confirmation in the hook plate at a planned second surgery. Results Sixty consecutive patients were enrolled: 30 in the T-plate group and 30 in the hook plate group. CMS showed similar functional outcomes for T-plates and hook plates at all follow-ups (Month 6: 92.0 vs. 91.7, P = 0.45). However, on the month 1 follow-up, the T-plate group scored higher than the hook plate group for ROM and pain (CMSpain = 13.0 vs. 12.3, P = 0.03; CMSROM = 35.2 vs. 33.2, P = 0.002). Despite this, Pain, ROM, and other CMS domains were comparable between groups (P > 0.05). The mean time to union was 2.5 + 1.4 months for the T-plate group and 2.3 + 1.6 months for the hook plate group (P = 0.44). There was one fixation failure in each group and one periprosthetic fracture in the hook plate group (two revisions for the hook plates and one for T-plates, P = 1.00). Non-union and other complications were not observed. Conclusion Both surgical approaches resulted in full recovery and good function. However, in the hook plate group ROM and pain scores were lower at 1 month. Standard non-locking T-plates are a viable alternative to hook plates with low cost and promising outcomes for treating displaced distal clavicle fractures.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] Treatment of unstable distal clavicle fractures (Neer type II): A comparison of three internal fixation methods
    Xiong, Jian
    Chen, Jian-Hai
    Dang, Yu
    Zhang, Dian-Ying
    Fu, Zhong-Guo
    Zhang, Pei-Xun
    JOURNAL OF INTERNATIONAL MEDICAL RESEARCH, 2018, 46 (11) : 4678 - 4683
  • [32] Comparison of the efficacy of a distal clavicular locking plate versus a clavicular hook plate in the treatment of unstable distal clavicle fractures and a systematic literature review
    Chunlin Zhang
    Junwu Huang
    Yi Luo
    Hua Sun
    International Orthopaedics, 2014, 38 : 1461 - 1468
  • [33] Risk factors for clavicular midshaft fractures after hook plate fixation for the treatment of Neer type II clavicular fractures
    Li, Yihan
    Tian, Qingxian
    Leng, Kunpeng
    Guo, Meng
    JOURNAL OF INTERNATIONAL MEDICAL RESEARCH, 2021, 49 (08)
  • [34] Fractures of the distal clavicle: outcomes and complications of surgical treatment using the hook plate
    Morales Davila, J.
    Domingo Trepat, A.
    Rios Martin, M.
    Carreno Delgado, A.
    Ballesteros Betancourt, J.
    Garcia Elvira, R.
    Garcia Tarrino, R.
    Camacho, P.
    Zumbado, A.
    Prat Fabregat, S.
    MINERVA ORTOPEDICA E TRAUMATOLOGICA, 2013, 64 (03) : 333 - 340
  • [35] Osteosynthesis of symptomatic nonunions of type II fractures of the distal clavicle using modified locking T-plate and bone grafting
    Kang, Ho-Jung
    Kim, Hyoung-Sik
    Kim, Sung-Jae
    Yoo, Je-Hyun
    JOURNAL OF TRAUMA AND ACUTE CARE SURGERY, 2012, 72 (02) : E14 - E19
  • [36] Comparison of four different treatment methods in distal clavicle fractures: Conservative treatment, locking plate, hook plate and tension band wiring
    Peker, Gokhan
    Abdioglu, Ahmet Atilla
    Karadeniz, Sercan
    Uygun, Huseyin
    Yukunc, Ismail
    Aslan, Oguzhan
    Karaca, Faruk
    ANNALS OF CLINICAL AND ANALYTICAL MEDICINE, 2023, 14 : 401 - 405
  • [37] Comparison of single coracoclavicular suture fixation and hook plate for the treatment of acute unstable distal clavicle fractures
    Chen, Chun-Yu
    Yang, Shan-Wei
    Lin, Kuan-Yu
    Lin, Kai-Cheng
    Tarng, Yih-Wen
    Renn, Jenn-Huei
    Lai, Chia-Hsin
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2014, 9
  • [38] Treatment of unstable distal clavicle fractures (Neer type IIb): a modified system using a miniature locking plate with a single button
    Ying, Hua
    Wang, Jihuan
    Sun, Yuehua
    Dai, Kerong
    Yu, Chao
    Yang, Fei
    JOURNAL OF INTERNATIONAL MEDICAL RESEARCH, 2021, 49 (06)
  • [39] Fixation of Unstable Type II Clavicle Fractures With Distal Clavicle Plate and Suture Button
    Johnston, Peter S.
    Sears, Benjamin W.
    Lazarus, Mark R.
    Frieman, Barbara G.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2014, 28 (11) : E269 - E272
  • [40] Treatment of Neer IIb Distal Clavicle Fractures Using Anatomical Locked Plate Fixation With Coracoclavicular Ligament Augmentation
    Han, Lei
    Hu, Yungen
    Quan, Renfu
    Fang, Weili
    Jin, Bo
    Huang, Ligang
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2017, 42 (12): : 1036.e1 - 1036.e6