Optimized Monitoring of Voltage Sags in Distribution Systems caused by Balanced and Unbalanced Short-Circuits

被引:0
作者
Kempner, T. R. [1 ]
Santos, A. Q. [1 ]
Oleskovicz, M. [1 ]
机构
[1] Univ Sao Paulo, Dept Elect & Comp Engn, Sao Carlos, SP, Brazil
来源
2014 IEEE PES GENERAL MEETING - CONFERENCE & EXPOSITION | 2014年
关键词
Distribution Systems; Fault Position Method; Optimal Allocation of Power Quality Monitors; Power Quality; Voltage Sags;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This research aims to apply the Method of Fault Positions to respond to difficulties found in the monitoring records of power distribution systems. In the context of power quality, resources for definition and evaluation of voltage sags indicators are pursued as a direct application of the method. This method uses computational simulations of symmetric and asymmetric short-circuits, by which the influence of each applied situation will also be verified to all buses of the distribution system. The optimal number of power quality monitors and the best positions for installing them on the distribution system will be also determined by applying the Branch-and-Bound algorithm. The purpose is to ensure the observability of the entire distribution system to any short-circuits. The proposed methodology is tested on two IEEE systems: IEEE 34-bus and IEEE 37-bus. The results obtained so far show the robustness and effectiveness of the proposed methodology and are reported in this work.
引用
收藏
页数:5
相关论文
共 14 条
  • [1] [Anonymous], 11591995 IEEE
  • [2] [Anonymous], 2005, THESIS CHALMERS U TE
  • [3] [Anonymous], 2009, PROC 15 INT C INTELL
  • [4] [Anonymous], 2007, DISTRIBUTION SYSTEM
  • [5] Bollen M. H. J., 1998, TOOLS TECHN DEAL UNC, p5/1
  • [6] Voltage sags: Effects, mitigation and prediction
    Bollen, MHJ
    [J]. POWER ENGINEERING JOURNAL, 1996, 10 (03): : 129 - 135
  • [7] PREDICTING AND PREVENTING PROBLEMS ASSOCIATED WITH REMOTE FAULT-CLEARING VOLTAGE DIPS
    CONRAD, L
    LITTLE, K
    GRIGG, C
    [J]. IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1991, 27 (01) : 167 - 172
  • [8] An Approach Based on Analytical Expressions for Optimal Location of Voltage Sags Monitors
    Espinosa-Juarez, Elisa
    Hernandez, Araceli
    Olguin, Gabriel
    [J]. IEEE TRANSACTIONS ON POWER DELIVERY, 2009, 24 (04) : 2034 - 2042
  • [9] IEEE PES Test Feeders, DISTR SYST AN SUBC
  • [10] VOLTAGE SAGS IN INDUSTRIAL-SYSTEMS
    MCGRANAGHAN, MF
    MUELLER, DR
    SAMOTYJ, MJ
    [J]. IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1993, 29 (02) : 397 - 403