On the AC-Connecting of a System for Active Filtering and Regeneration in Active DC-Traction Substations

被引:0
作者
Popescu, Mihaela [1 ]
Bitoleanu, Alexandru [1 ]
Dobriceanu, Mircea [1 ]
Teodorescu, Florin Alexandru [2 ]
机构
[1] Univ Craiova, Fac Elect Engn, Craiova, Romania
[2] Arc Elect, Brasov, Romania
来源
2018 INTERNATIONAL CONFERENCE ON APPLIED AND THEORETICAL ELECTRICITY (ICATE) | 2018年
关键词
DC-traction; active filtering; regeneration; LCL filter; damping resistance; LCL FILTER; DESIGN;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper presents a new approach in the AC-connection filter design of a shunt active power filter based on three-phase voltage source inverter. The practical case study is of a LCL passive filter with damping resistors connected to the output of the inverter in an active DC-traction substation with 12-pulse parallel diode rectifier. Starting from the functions to be fulfilled, the design conditions are based on the transfer function related to the input and output currents. They consist of imposing the magnitude response at the switching frequency, as well as the position of the resonance frequency relative to the frequency of the highest order harmonic to be compensated. The design algorithm is fully formulated, some limitations are expressed and specific performance indicators are proposed. Through simulation in Matlab-Simulink environment, the proper operation of the whole system, including the designed interface filter, is illustrated.
引用
收藏
页数:6
相关论文
共 22 条
[1]  
[Anonymous], P POW EL MOT CONTR P
[2]  
[Anonymous], PRZ ELEKTROTECH
[3]  
[Anonymous], P IEEE VEH POW PROP
[4]  
Bitoleanu A., 2016, 2016 International Symposium on Power Electronics, Electrical Drives, Automation and Motion (SPEEDAM), P671, DOI 10.1109/SPEEDAM.2016.7525898
[5]  
Bitoleanu A, 2017, 2017 INTERNATIONAL CONFERENCE ON OPTIMIZATION OF ELECTRICAL AND ELECTRONIC EQUIPMENT (OPTIM) & 2017 INTL AEGEAN CONFERENCE ON ELECTRICAL MACHINES AND POWER ELECTRONICS (ACEMP), P759, DOI 10.1109/OPTIM.2017.7975060
[6]  
Brociek Wieslaw, 2014, Przeglad Elektrotechniczny, V90, P67, DOI 10.12915/pe.2014.05.14
[7]  
Djeghader Y., 2015, P 7 INT C MOD ID CON
[8]   Power Quality Conditioners for Railway Traction - a Review [J].
Gunavardhini, N. ;
Chandrasekaran, M. .
AUTOMATIKA, 2016, 57 (01) :150-162
[9]   Two Degrees of Freedom Active Damping Technique for LCL Filter-Based Grid Connected PV Systems [J].
Hanif, Moin ;
Khadkikar, Vinod ;
Xiao, Weidong ;
Kirtley, James L., Jr. .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2014, 61 (06) :2795-2803
[10]  
Hosny W., 2013, J ENERGY POWER ENG, P1974