An optoelectronic flow-through detectors for active ingredients determination in the pharmaceutical formulations

被引:12
|
作者
Jeber, Jalal N. [1 ]
Turkey, Nagham S. [1 ]
机构
[1] Univ Baghdad, Coll Sci, Dept Chem, Baghdad, Al Jadriya, Iraq
关键词
Optoelectronic detector; Quality control; Micro-flow injection analysis; Fabrication of spectroscopy devices; Pharmaceutical formulations analysis; CHROMOTROPIC-ACID; WARFARIN; FLUORESCENCE; PLATFORM; NITRATE; SYSTEM; DEVICE; PEDD;
D O I
10.1016/j.jpba.2021.114128
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An optoelectronic flow-through detector for active ingredients determination in pharmaceutical for-mulations is explained. Two consecutive compact photodetector's devices operating according to light-emitting diodes-solar cells concept where the LEDs acting as a light source and solar cells for mea-suring the attenuated light of the incident light at 180 degrees have been developed. The turbidimetric detector, fabricated of ten light-emitting diodes and five solar cells only, integrated with a glass flow cell has been easily adapted in flow injection analysis manifold system. For active ingredients determination, the developed detector was successfully utilized for the development and validation of an analytical method for warfarin determination in pure and pharmaceutical preparations. The developed method is based on the forming of a white, turbid product as a result of a reaction between the warfarin and semicarbazide which was used as an oxidizing agent. The developed flow-through detector system is semi mechanized, economic in materials consumption, easy to operate and characterized by excellent analytical results. Both developed analytical devices used in two channels flow injection system allow for turbidimetric measurements of warfarin in 0.9-154 mu g ml(-1) and 123-1600 mu g ml(-1) ranges of concentration, with lim-its of detections 0.73 mu g ml(-1) and 24.66 mu g ml(-1) for photodetectors 1& 2 respectively. The turbidity measurement procedure for the current flow system offers to conduct 60 tests per hour of the warfarin which is the most needs of quality control analysis in industrial applications. To ensure the analytical usefulness of the flow system, the warfarin has been analyzed in the real samples with a fully acceptable agreement and a correlation between the results offered by the developed flow system and the official method. (C) 2021 Elsevier B.V. All rights reserved.
引用
收藏
页数:11
相关论文
共 34 条
  • [1] A flow analysis system integrating an optoelectronic detector for the quantitative determination of active ingredients in pharmaceutical formulations
    Turkey, Nagham S.
    Jeber, Jalal N.
    MICROCHEMICAL JOURNAL, 2021, 160
  • [2] A bimodal optoelectronic flow-through detector for phosphate determination
    Fiedoruk, Marta
    Mieczkowska, Elzbieta
    Koncki, Robert
    Tymecki, Lukasz
    TALANTA, 2014, 128 : 211 - 214
  • [3] Optoelectronic iron detectors for pharmaceutical flow analysis
    Rybkowska, Natalia
    Koncki, Robert
    Strzelak, Kamil
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2017, 145 : 504 - 508
  • [4] Quantification of active ingredients in semi-solid pharmaceutical formulations by near infrared spectroscopy
    Schlegel, Lisa B.
    Schubert-Zsilavecz, Manfred
    Abdel-Tawab, Mona
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2017, 142 : 178 - 189
  • [5] Flow-through fluorescence immunosensor for IgG determination in serum
    DiazGarcia, ME
    delosToyos, JR
    Sampedro, A
    ValenciaGonzalez, MJ
    SalasBustamante, A
    MEDICAL AND FIBER OPTIC SENSORS AND DELIVERY SYSTEMS, PROCEEDINGS OF, 1996, 2631 : 37 - 44
  • [6] Multicommuted flow-through fluorescence optosensor for determination of furosemide and triamterene
    Llorent-Martínez, E
    Ortega-Barrales, P
    Molina-Díaz, A
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2005, 383 (05) : 797 - 803
  • [7] HILIC-MS determination of dimethylamine in the active pharmaceutical ingredients and in the dosage forms of metformin
    Dousa, Michal
    Jires, Jakub
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2020, 191
  • [8] Multicommuted flow-through fluorescence optosensor for determination of furosemide and triamterene
    E. J. Llorent-Martínez
    P. Ortega-Barrales
    A. Molina-Díaz
    Analytical and Bioanalytical Chemistry, 2005, 383 : 797 - 803
  • [9] Recent Applications of Capillary Electrophoresis in the Determination of Active Compounds in Medicinal Plants and Pharmaceutical Formulations
    Gackowski, Marcin
    Przybylska, Anna
    Kruszewski, Stefan
    Koba, Marcin
    Madra-Gackowska, Katarzyna
    Bogacz, Artur
    MOLECULES, 2021, 26 (14):
  • [10] The impact of glidants on the rheological properties of active pharmaceutical ingredients: A study of conventional and alternative flow enhancers
    Verbeek, Tom
    De Man, Alexander
    Van Snick, Bernd
    Otava, Martin
    Vervaet, Chris
    Vanhoorne, Valerie
    INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2025, 671