High-resolution metal artifact reduction MR imaging of the lumbosacral plexus in patients with metallic implants

被引:23
作者
Ahlawat, Shivani [1 ]
Stern, Steven E. [2 ]
Belzberg, Allan J. [3 ]
Fritz, Jan [1 ]
机构
[1] Johns Hopkins Med Inst, Russell H Morgan Dept Radiol & Radiol Sci, 600 North Wolfe St, Baltimore, MD 21287 USA
[2] Bond Univ, Bond Business Sch, Gold Coast, Qld 4229, Australia
[3] Johns Hopkins Univ, Sch Med, Dept Neurosurg, 600 North Wolfe St, Baltimore, MD 21287 USA
关键词
MR imaging; Metal artifact reduction; Lumbosacral plexus; Peripheral neuropathy; TOTAL HIP-ARTHROPLASTY; NERVE PALSY; PERIPHERAL NEUROPATHIES; TIME;
D O I
10.1007/s00256-017-2630-9
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
To assess the quality and accuracy of metal artifact reduction sequence (MARS) magnetic resonance imaging (MRI) for the diagnosis of lumbosacral neuropathies in patients with metallic implants in the pelvis. Twenty-two subjects with lumbosacral neuropathy following pelvic instrumentation underwent 1.5-T MARS MRI including optimized axial intermediate-weighted and STIR turbo spin echo sequences extending from L5 to the ischial tuberosity. Two readers graded the visibility of the lumbosacral trunk, sciatic, femoral, lateral femoral cutaneous, and obturator nerves and the nerve signal intensity of nerve, architecture, caliber, course, continuity, and skeletal muscle denervation. Clinical examination and electrodiagnostic studies were used as the standard of reference. Descriptive, agreement, and diagnostic performance statistics were applied. Lumbosacral plexus visibility on MARS MRI was good (4) or very good (3) in 92% of cases with 81% exact agreement and a Kendall's W coefficient of 0.811. The obturator nerve at the obturator foramen and the sciatic nerve posterior to the acetabulum had the lowest visibility, with good or very good ratings in only 61% and 77% of cases respectively. The reader agreement for nerve abnormalities on MARS MRI was excellent, ranging from 95.5 to 100%. MARS MRI achieved a sensitivity of 86%, specificity of 67%, positive predictive value of 95%, and negative predictive value of 40%, and accuracy of 83% for the detection of neuropathy. MARS MRI yields high image quality and diagnostic accuracy for the assessment of lumbosacral neuropathies in patients with metallic implants of the pelvis and hips.
引用
收藏
页码:897 / 908
页数:12
相关论文
共 29 条
[11]   Three-Dimensional CAIPIRINHA SPACE TSE for 5-Minute High-Resolution MRI of the Knee [J].
Fritz, Jan ;
Fritz, Benjamin ;
Thawait, Gaurav G. ;
Meyer, Heiko ;
Gilson, Wesley D. ;
Raithel, Esther .
INVESTIGATIVE RADIOLOGY, 2016, 51 (10) :609-617
[12]   Compressed Sensing SEMAC: 8-fold Accelerated High Resolution Metal Artifact Reduction MRI of Cobalt-Chromium Knee Arthroplasty Implants [J].
Fritz, Jan ;
Ahlawat, Shivani ;
Demehri, Shadpour ;
Thawait, Gaurav K. ;
Raithel, Esther ;
Gilson, Wesley D. ;
Nittka, Mathias .
INVESTIGATIVE RADIOLOGY, 2016, 51 (10) :666-676
[13]   Advanced metal artifact reduction MRI of metal-on-metal hip resurfacing arthroplasty implants: compressed sensing acceleration enables the time-neutral use of SEMAC [J].
Fritz, Jan ;
Fritz, Benjamin ;
Thawait, Gaurav K. ;
Raithel, Esther ;
Gilson, Wesley D. ;
Nittka, Mathias ;
Mont, Michael A. .
SKELETAL RADIOLOGY, 2016, 45 (10) :1345-1356
[14]   MR Imaging of Hip Arthroplasty Implants [J].
Fritz, Jan ;
Lurie, Brett ;
Miller, Theodore T. ;
Potter, Hollis G. .
RADIOGRAPHICS, 2014, 34 (04) :E106-E132
[15]   Magnetic resonance imaging of the postoperative hip [J].
Hayter, Catherine L. ;
Koff, Matthew F. ;
Potter, Hollis G. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2012, 35 (05) :1013-1025
[16]   MRI After Arthroplasty: Comparison of MAVRIC and Conventional Fast Spin-Echo Techniques [J].
Hayter, Catherine L. ;
Koff, Matthew F. ;
Shah, Parina ;
Koch, Kevin M. ;
Miller, Theodore T. ;
Potter, Hollis G. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2011, 197 (03) :W405-W411
[17]   Accuracy of MRI in Diagnosing Peripheral Nerve Disease: A Systematic Review of the Literature [J].
Kwee, Robert M. ;
Chhabra, Avneesh ;
Wang, Kenneth C. ;
Marker, David R. ;
Carrino, John A. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2014, 203 (06) :1303-1309
[18]   OBTURATOR NEUROPATHY AFTER TOTAL HIP-REPLACEMENT [J].
MELAMED, NB ;
SATYAMURTI, S .
ANNALS OF NEUROLOGY, 1983, 13 (05) :578-579
[19]   Evaluation of metal artifacts in clinical MR images of patients with total hip arthroplasty using different metal artifact-reducing sequences [J].
Muller, Gunilla M. ;
Lundin, Bjorn ;
von Schewelov, Thord ;
Muller, Markus F. ;
Ekberg, Olle ;
Mansson, Sven .
SKELETAL RADIOLOGY, 2015, 44 (03) :353-359
[20]  
Navarro R A, 1995, J Arthroplasty, V10, P1