The Performance of Alternative Refrigerant Gas R152a as Mobile Air Conditioning Refrigerant

被引:7
|
作者
Bilen, Kadir [1 ]
Kalkisim, Ahmet T. [2 ]
Solmus, Ismail [1 ]
机构
[1] Ataturk Univ, Dept Mech Engn, TR-25040 Erzurum, Turkey
[2] Gumushane Univ, Vocat Coll, Dept Elect & Control Syst, Gumushane, Turkey
来源
PRES 2014, 17TH CONFERENCE ON PROCESS INTEGRATION, MODELLING AND OPTIMISATION FOR ENERGY SAVING AND POLLUTION REDUCTION, PTS 1-3 | 2014年 / 39卷
关键词
Air conditioning;
D O I
10.3303/CET1439301
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In this study, the possible alternative replacement of R134a with R152 in the air conditioning (AC) system of an automobile has been investigated theoretically. The properties of the R152a is presented and compared with three different refrigerants (R134a, R22 and R12). At a constant condenser temperature, the effect of evaporator temperature (T-e=-20 degrees C - 0 degrees C) and compressor speed (n = 600 - 2,000 rpm) on the cooling load, the condenser heat load, compressor work, the mass flow rate of refrigerant and performance coefficient of the AC system have been examined with the help of a commercial computer program for refrigerants investigated. It was found that R152a and R134a do not lead to any significant difference on the performance of the refrigeration system. This result shows that with small modifications on the AC systems of current automobiles commonly using R134a, R-152a can be used as an alternative refrigerant since their compression ratios are almost the same.
引用
收藏
页码:1801 / +
页数:2
相关论文
共 50 条
  • [21] THERMODYNAMIC PROPERTIES OF A NEW REFRIGERANT - A BINARY AZEOTROPE BASED ON R152A AND R218
    LAVRENCHENKO, GK
    KHMELNUK, MG
    RUVINSKIJ, GY
    ILJUSHENKO, SV
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 1994, 17 (07): : 461 - 468
  • [22] Investigation on the environmental impact of R32, R152a and R41 refrigerant blends
    Karthik, M. S. Kiran
    Samuel, K. John
    Bhargav, K. Pawan
    Varma, K. S. Dileep
    Subramanian, Anirudh
    Kanna, N. Santhosh
    Bibin, B. S.
    Gundabattini, Edison
    ENGINEERING RESEARCH EXPRESS, 2023, 5 (02):
  • [23] Experimental comparisons on a gas engine heat pump using R134a and low-GWP refrigerant R152a
    Ma, Zhenxi
    Liu, Fengguo
    Tian, Changfei
    Jia, Leilei
    Wu, Wei
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2020, 115 : 73 - 82
  • [24] Carbon dioxide as an alternative refrigerant for automotive air conditioning systems
    Mathur, GD
    35TH INTERSOCIETY ENERGY CONVERSION ENGINEERING CONFERENCE & EXHIBIT (IECEC), VOLS 1 AND 2, TECHNICAL PAPERS, 2000, : 371 - 379
  • [25] THE TRIBOLOGY OF AN AUTOMOTIVE AIR-CONDITIONING SYSTEM WITH AN ALTERNATIVE REFRIGERANT
    NATSUME, Y
    ARAHIRA, K
    JOURNAL OF JAPANESE SOCIETY OF TRIBOLOGISTS, 1995, 40 (09) : 718 - 723
  • [26] Effect of refrigerant charge on the performance of air conditioning systems
    Goswami, DY
    Ek, G
    Leung, M
    Jotshi, CK
    Sherif, SA
    Colacino, F
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2001, 25 (08) : 741 - 750
  • [27] Molecular modeling and simulation of vapor-liquid equilibrium of the refrigerant R152a and its mixture R152a+R32
    Yang, Zhi
    Gong, Maoqiong
    Dong, Xueqiang
    Li, Xiaodong
    Wu, Jianfeng
    FLUID PHASE EQUILIBRIA, 2015, 394 : 93 - 100
  • [28] MOLECULAR-DYNAMICS STUDIES FOR THE NEW REFRIGERANT R152A WITH SIMPLE-MODEL POTENTIALS
    VEGA, C
    SAAGER, B
    FISCHER, J
    MOLECULAR PHYSICS, 1989, 68 (05) : 1079 - 1093
  • [29] MEASUREMENTS OF THE VAPOR LIQUID COEXISTENCE CURVE IN THE CRITICAL REGION FOR REFRIGERANT MIXTURE R152A/R22
    WANG, J
    LIU, ZG
    TAN, LC
    YIN, JM
    FLUID PHASE EQUILIBRIA, 1992, 80 : 203 - 211
  • [30] The refrigerant R1234yf in air conditioning systems
    Zilio, Claudio
    Brown, J. Steven
    Schiochet, Giovanni
    Cavallini, Alberto
    ENERGY, 2011, 36 (10) : 6110 - 6120