The effect of intraocular lens tilt on visual outcomes in scleral-fixated intraocular lens implantation

被引:24
作者
Atik, Burcu Kemer [1 ]
Altan, Cigdem [2 ]
Agca, Alper [2 ]
Kirmaci, Asli [2 ]
Yildirim, Yusuf [2 ]
Genc, Selim [2 ]
Taskapil, Muhittin [2 ]
机构
[1] Univ Hlth Sci, Gaziosmanpasa Training & Res Hosp, Istanbul, Turkey
[2] Univ Hlth Sci, Beyoglu Eye Training & Res Hosp, Istanbul, Turkey
关键词
Anterior segment OCT; Aphakia; Secondary intraocular lens implantation; Scleral fixation; Tilt of intraocular lens; Z-suture technique; ANTERIOR-CHAMBER; DECENTRATION;
D O I
10.1007/s10792-019-01233-2
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose To investigate the effect of scleral-fixated intraocular lens (IOL) tilt on visual outcomes. Methods Ninety-four eyes of consecutive 94 patients who underwent scleral-fixated IOL implantation with Z-suture technique were included in this prospective study. The values of pre- and postoperative 12th month uncorrected visual acuity (UCVA), cylindrical refractive error, best-corrected visual acuity (BCVA) and corneal and lenticular astigmatism were recorded. The position of the implanted IOL was evaluated with anterior segment optical coherence tomography (AS-OCT). The relationships between the AS-OCT measurements and the visual acuity or refractive errors were investigated. Results The IOL position was evaluated as tilted in 68 (72.3%) patients: 29 (30.8%) in both vertical + horizontal axes, 30 (31.9%) in the horizontal axis and 9 (9.6%) in the vertical axis. There were no significant differences between patients with and without tilt IOL position in terms of the UCVA, BCVA, cylindrical refractive error and lenticular astigmatism (p > 0.05, for each). The mean BCVA was significantly higher in the no-tilt group than in the both horizontal + vertical tilt and the vertical tilt groups (p = 0.03, p = 0.04, respectively). The mean lenticular astigmatism was significantly higher in the vertical tilt group than the other groups (p = 0.04). Conclusion Tilting in IOL position occurs commonly; however, IOLs with tilting on any of the axes do not have significantly worse outcomes when compared with IOLs with no tilt, in terms of visual results and refractive errors. On the other hand, tilting on the vertical axis is observed less commonly, yet is more effective on visual results and refractive errors, when compared with tilting on the horizontal axis.
引用
收藏
页码:717 / 724
页数:8
相关论文
共 50 条
  • [41] MYX technique: A modified adaptation of Yamane and extraocular needle-guided haptic insertion techniques for scleral-fixated intraocular lens implantation
    Bhatia, Karan
    Manaktala, Ruchita
    Sachdev, Mahipal
    Tank, Nikunj
    Saha, Indranil
    Mishra, Deepak
    [J]. INDIAN JOURNAL OF OPHTHALMOLOGY, 2021, 69 (02) : 428 - +
  • [42] Comparative analysis of retropupillary iris claw versus scleral-fixated intraocular lens in the management of post-cataract aphakia
    Madhivanan, Nivean
    Sengupta, Sabyasachi
    Sindal, Manavi
    Nivean, Pratheeba Devi
    Kumar, Maitri Arun
    Ariga, Murali
    [J]. INDIAN JOURNAL OF OPHTHALMOLOGY, 2019, 67 (01) : 59 - 63
  • [43] Outcome of sutured scleral fixated intraocular lens in Marfan syndrome in pediatric eyes
    Sen, Parveen
    Attiku, Yamini
    Bhende, Pramod
    Rishi, Ekta
    Ratra, Dhanashree
    Sreelakshmi, Kummamuri
    [J]. INTERNATIONAL OPHTHALMOLOGY, 2020, 40 (06) : 1531 - 1538
  • [44] Outcome of sutured scleral fixated intraocular lens in Marfan syndrome in pediatric eyes
    Parveen Sen
    Yamini Attiku
    Pramod Bhende
    Ekta Rishi
    Dhanashree Ratra
    Kummamuri Sreelakshmi
    [J]. International Ophthalmology, 2020, 40 : 1531 - 1538
  • [45] Optic inversion of scleral-fixated intraocular lens after vitrectomy with fluid-air exchange: case series and review of the literature
    Cameron, Nathaniel W.
    Karadaghy, Amin
    Mitchell, Mary K.
    Ajlan, Radwan S.
    [J]. JOURNAL OF SURGICAL CASE REPORTS, 2023, 2023 (11):
  • [46] Secondary intraocular lens implantation using scleral suture fixation
    Szurman, P.
    Gekeler, K.
    [J]. OPHTHALMOLOGE, 2014, 111 (03): : 217 - 223
  • [47] Dislocation force of scleral flange-fixated intraocular lens haptics
    Spela Stunf Pukl
    Martin Kronschläger
    Manuel Ruiss
    Stéphane Blouin
    Emre Rüştü Akcan
    Oliver Findl
    [J]. BMC Ophthalmology, 24
  • [48] Dislocation force of scleral flange-fixated intraocular lens haptics
    Pukl, Spela Stunf
    Kronschlaeger, Martin
    Ruiss, Manuel
    Blouin, Stephane
    Akcan, Emre Ruestue
    Findl, Oliver
    [J]. BMC OPHTHALMOLOGY, 2024, 24 (01)
  • [49] Novel technique of sutureless glueless scleral fixated intraocular lens (SFIOL)
    Walia, Shweta
    Kashyap, Santosh
    Bhaisare, V.
    Rawat, P.
    Kori, N.
    [J]. INDIAN JOURNAL OF OPHTHALMOLOGY, 2019, 67 (01) : 64 - 68
  • [50] Scleral Fixated Intraocular Lens in Aphakic Patient with Bilateral Microcornea and Microphthalmia
    Alwohaibi, Nada N.
    Aljindan, Mohanna Y.
    AlRashidi, Fatimah N.
    [J]. INTERNATIONAL MEDICAL CASE REPORTS JOURNAL, 2021, 14 : 365 - 369