Evaluation of the performance indices of a ventilated double window through experimental and analytical procedures: SHGC-values

被引:31
作者
Carlos, Jorge S. [1 ]
Corvacho, Helena [2 ]
机构
[1] Univ Beira Interior, Ctr Mat & Bldg Technol, CMADE, Covilha, Portugal
[2] Univ Porto, Fac Engn, Dept Civil Engn, Bldg Div,Lab Bldg Phys, P-4100 Oporto, Portugal
关键词
Ventilated double window; Experimental measurements; Calculated parameters; Solar heat gain coefficient (SHGC); SOLAR HEAT GAIN; SUPPLY AIR WINDOW; THERMAL PERFORMANCE; SIMULATION; EFFICIENCY; ENERGY;
D O I
10.1016/j.enbuild.2014.11.002
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
A double ventilated window is formed by two parallel windows in the same facade opening with a ventilated air-channel between them. Under inward flow conditions and incident solar radiation this works as a solar collector. The solar radiation absorbed by the outer and inner windows heats up the passing air in the air channel before it is delivered inside. Still, part of the solar radiation reaches directly the indoor environment through the glazed part. This paper is a presentation of an experimental and analytical study of the solar heat gain coefficient (SHGC) of a ventilated double window under different working conditions and for several types of glasses and different glass to frame ratios. The variation of SHGC values with each influent factor is provided which can be useful for a dynamic whole building energy analysis. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:886 / 897
页数:12
相关论文
共 32 条
  • [1] Alexander D.K., 2005, 9 INT IBPSA C BUILD, P11
  • [2] [Anonymous], 2003, ISO 15099
  • [3] Influence of cavities geometric and emissivity properties on the overall thermal performance of aluminum frames for windows
    Asdrubali, Francesco
    Baldinelli, Giorgio
    Bianchi, Francesco
    [J]. ENERGY AND BUILDINGS, 2013, 60 : 298 - 309
  • [4] On the Evaluation of Solar Greenhouse Efficiency in Building Simulation during the Heating Period
    Asdrubali, Francesco
    Cotana, Franco
    Messineo, Antonio
    [J]. ENERGIES, 2012, 5 (06): : 1864 - 1880
  • [5] ASHRAE-American Society of Heating Refrigeration and Air-Conditioning Engineers Inc., 1985, ASHRAE HDB
  • [6] Test cell analysis of the use of a supply air window as a passive solar component
    Baker, PH
    McEvoy, M
    [J]. SOLAR ENERGY, 2000, 69 (02) : 113 - 130
  • [7] SOLAR HEAT GAIN FACTORS AND HEAT-LOSS COEFFICIENTS FOR PASSIVE HEATING CONCEPTS
    BHANDARI, MS
    BANSAL, NK
    [J]. SOLAR ENERGY, 1994, 53 (02) : 199 - 208
  • [8] Evaluation of the thermal performance indices of a ventilated double window through experimental and analytical procedures: UW-values
    Carlos, Jorge S.
    Corvacho, Helena
    [J]. RENEWABLE ENERGY, 2014, 63 : 747 - 754
  • [9] Heat recovery versus solar collection in a ventilated double window
    Carlos, Jorge S.
    Corvacho, Helena
    Silva, Pedro D.
    Castro-Gomes, J. P.
    [J]. APPLIED THERMAL ENGINEERING, 2012, 37 : 258 - 266
  • [10] Modelling and simulation of a ventilated double window
    Carlos, Jorge S.
    Corvacho, Helena
    Silva, Pedro D.
    Castro-Gomes, J. P.
    [J]. APPLIED THERMAL ENGINEERING, 2011, 31 (01) : 93 - 102