Comprehensive two-dimensional gas chromatographic separations with a temperature programmed microfabricated thermal modulator

被引:16
|
作者
Collin, William R. [1 ,4 ]
Nunovero, Nicolas [2 ,4 ]
Paul, Dibyadeep [3 ,4 ]
Kurabayashi, Katsuo [3 ,4 ]
Zellers, Edward T. [1 ,2 ,4 ]
机构
[1] Univ Michigan, Dept Chem, Ann Arbor, MI 48109 USA
[2] Univ Michigan, Dept Environm Hlth Sci, Ann Arbor, MI 48109 USA
[3] Univ Michigan, Dept Mech Engn, Ann Arbor, MI 48109 USA
[4] Univ Michigan, Ctr Wireless Integrated MicroSensing & Syst WIMS2, Ann Arbor, MI 48109 USA
基金
美国国家科学基金会;
关键词
GC x GC; Microfabricated; Micro gas chromatography; Thermal modulation; RTIL; MASS-SPECTROMETER; IONIC LIQUIDS; GC; FLOW; PERFORMANCE;
D O I
10.1016/j.chroma.2016.03.072
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Comprehensive two-dimensional gas chromatography (GC x GC) with a temperature-programmed microfabricated thermal modulator (mu TM) is demonstrated. The 0.78 cm(2), 2-stage mu TM chip with integrated heaters and a PDMS coated microchannel was placed in thermal contact with a solid-state thermoelectric cooler and mounted on top of a bench scale GC. It was fluidically coupled through heated interconnects to an upstream first-dimension (D-1) PDMS-coated capillary column and a downstream uncoated capillary or second-dimension (D-2) PEG-coated capillary. A mixture of n-alkanes C-6-C-10 was separated isothermally and the full-width-at-half-maximum (fwhm) values of the modulated peaks were assessed as a function of the computer-controlled minimum and maximum stage temperatures of mu TM, T-min, and T-max, respectively. With T-min, and T-max fixed at -25 and 100 degrees C, respectively, modulated peaks of C-6 and C-7 had fwhm values <53 ms while the modulated peaks of C-10 had a fwhm value of 1.3 s, due to inefficient re-mobilization. With T-min and T-max fixed at 0 and 210 degrees C, respectively, the fwhm value for the modulated C10 peaks decreased to 67 ms, but C-6 and C-7 exhibited massive breakthrough. By programming T-min from -25 to 0 degrees C and Tmax from 100 to 220 degrees C, the C-6 and C-7 peaks had fwhm values <= 50 ms, and the fwhm for C-10 peaks remained <95 ms. Using the latter conditions for the GC x GC separation of a sample of unleaded gasoline yielded resolution similar to that reported with a commercial thermal modulator. Replacing the PDMS phase in the mu TM with a trigonal-tricationic room temperature ionic liquid eliminated the bleed observed with the PDMS, but also reduced the capacity for several test compounds. Regardless, the demonstrated capability to independently temperature program this low resource mu TM enhances its versatility and its promise for use in bench-scale GC x GC systems. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:114 / 122
页数:9
相关论文
共 50 条
  • [21] Effects of variation in modulator temperature during cryogenic modulation in comprehensive two-dimensional gas chromatography
    Begnaud, Frederic
    Debonneville, Christian
    Probst, Jean-Pierre
    Chaintreau, Alain
    Morrison, Paul D.
    Adcock, Jacqui L.
    Marriott, Philip J.
    JOURNAL OF SEPARATION SCIENCE, 2009, 32 (18) : 3144 - 3151
  • [22] Observations on "orthogonality" in comprehensive two-dimensional separations
    Watson, Hathanial E.
    Davis, Joe M.
    Synovec, Robert E.
    ANALYTICAL CHEMISTRY, 2007, 79 (20) : 7924 - 7927
  • [23] New valve switching modulator for comprehensive two-dimensional gas chromatography
    Wang, Frank Cheng-Yu
    JOURNAL OF CHROMATOGRAPHY A, 2008, 1188 (02) : 274 - 280
  • [24] Chemometric analysis of comprehensive two-dimensional separations
    Synovec, RE
    Prazen, BJ
    Johnson, KJ
    Fraga, CG
    Bruckner, CA
    ADVANCES IN CHROMATOGRAPHY, VOL 42, 2003, 42 : 1 - 42
  • [25] Comprehensive two-dimensional separations using microcolumns
    Liu, ZY
    Lee, ML
    JOURNAL OF MICROCOLUMN SEPARATIONS, 2000, 12 (04) : 241 - 254
  • [26] Comprehensive two-dimensional separations using microcolumns
    Liu, Zaiyou
    Lee, Milton L.
    Journal of Microcolumn Separation, 2000, 12 (04): : 241 - 254
  • [27] Predictions of comprehensive two-dimensional gas chromatography separations from isothermal data
    Zhu, Shukui
    He, Sheng
    Worton, David R.
    Goldstein, Allen H.
    JOURNAL OF CHROMATOGRAPHY A, 2012, 1233 : 147 - 151
  • [28] A fast temperature-programmed second-dimension column for comprehensive two-dimensional gas chromatography
    Cai, Huamin
    Stearns, Stanley D. D.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2023, 415 (13) : 2435 - 2446
  • [29] A fast temperature-programmed second-dimension column for comprehensive two-dimensional gas chromatography
    Huamin Cai
    Stanley D. Stearns
    Analytical and Bioanalytical Chemistry, 2023, 415 : 2435 - 2446
  • [30] Twin comprehensive two-dimensional gas chromatographic system: concept and applications
    Adahchour, M
    Jover, E
    Beens, J
    Vreuls, RJJ
    Brinkman, UAT
    JOURNAL OF CHROMATOGRAPHY A, 2005, 1086 (1-2) : 128 - 134