Comprehensive two-dimensional gas chromatographic separations with a temperature programmed microfabricated thermal modulator

被引:16
|
作者
Collin, William R. [1 ,4 ]
Nunovero, Nicolas [2 ,4 ]
Paul, Dibyadeep [3 ,4 ]
Kurabayashi, Katsuo [3 ,4 ]
Zellers, Edward T. [1 ,2 ,4 ]
机构
[1] Univ Michigan, Dept Chem, Ann Arbor, MI 48109 USA
[2] Univ Michigan, Dept Environm Hlth Sci, Ann Arbor, MI 48109 USA
[3] Univ Michigan, Dept Mech Engn, Ann Arbor, MI 48109 USA
[4] Univ Michigan, Ctr Wireless Integrated MicroSensing & Syst WIMS2, Ann Arbor, MI 48109 USA
基金
美国国家科学基金会;
关键词
GC x GC; Microfabricated; Micro gas chromatography; Thermal modulation; RTIL; MASS-SPECTROMETER; IONIC LIQUIDS; GC; FLOW; PERFORMANCE;
D O I
10.1016/j.chroma.2016.03.072
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Comprehensive two-dimensional gas chromatography (GC x GC) with a temperature-programmed microfabricated thermal modulator (mu TM) is demonstrated. The 0.78 cm(2), 2-stage mu TM chip with integrated heaters and a PDMS coated microchannel was placed in thermal contact with a solid-state thermoelectric cooler and mounted on top of a bench scale GC. It was fluidically coupled through heated interconnects to an upstream first-dimension (D-1) PDMS-coated capillary column and a downstream uncoated capillary or second-dimension (D-2) PEG-coated capillary. A mixture of n-alkanes C-6-C-10 was separated isothermally and the full-width-at-half-maximum (fwhm) values of the modulated peaks were assessed as a function of the computer-controlled minimum and maximum stage temperatures of mu TM, T-min, and T-max, respectively. With T-min, and T-max fixed at -25 and 100 degrees C, respectively, modulated peaks of C-6 and C-7 had fwhm values <53 ms while the modulated peaks of C-10 had a fwhm value of 1.3 s, due to inefficient re-mobilization. With T-min and T-max fixed at 0 and 210 degrees C, respectively, the fwhm value for the modulated C10 peaks decreased to 67 ms, but C-6 and C-7 exhibited massive breakthrough. By programming T-min from -25 to 0 degrees C and Tmax from 100 to 220 degrees C, the C-6 and C-7 peaks had fwhm values <= 50 ms, and the fwhm for C-10 peaks remained <95 ms. Using the latter conditions for the GC x GC separation of a sample of unleaded gasoline yielded resolution similar to that reported with a commercial thermal modulator. Replacing the PDMS phase in the mu TM with a trigonal-tricationic room temperature ionic liquid eliminated the bleed observed with the PDMS, but also reduced the capacity for several test compounds. Regardless, the demonstrated capability to independently temperature program this low resource mu TM enhances its versatility and its promise for use in bench-scale GC x GC systems. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:114 / 122
页数:9
相关论文
共 50 条
  • [1] Comprehensive Two-Dimensional Gas Chromatographic Separations with a Microfabricated Thermal Modulator
    Serrano, Gustavo
    Paul, Dibyadeep
    Kim, Sung-Jin
    Kurabayashi, Katsuo
    Zellers, Edward T.
    ANALYTICAL CHEMISTRY, 2012, 84 (16) : 6973 - 6980
  • [2] μGC x μGC: Comprehensive Two-Dimensional Gas Chromatographic Separations with Microfabricated Components
    Collin, William R.
    Bondy, Amy
    Paul, Dibyadeep
    Kurabayashi, Katsuo
    Zellers, Edward T.
    ANALYTICAL CHEMISTRY, 2015, 87 (03) : 1630 - 1637
  • [3] Evaluation of a Microfabricated Thermal Modulator for Comprehensive Two-Dimensional Microscale Gas Chromatography
    Kim, Sung-Jin
    Serrano, Gustavo
    Wise, Kensall D.
    Kurabayashi, Katsuo
    Zellers, Edward T.
    ANALYTICAL CHEMISTRY, 2011, 83 (14) : 5556 - 5562
  • [4] Microfabricated thermal modulator for comprehensive two-dimensional micro gas chromatography: design, thermal modeling, and preliminary testing
    Kim, Sung-Jin
    Reidy, Shaelah M.
    Block, Bruce P.
    Wise, Kensall D.
    Zellers, Edward T.
    Kurabayashi, Katsuo
    LAB ON A CHIP, 2010, 10 (13) : 1647 - 1654
  • [5] Programmed automation of modulator cold jet flow for comprehensive two-dimensional gas chromatographic analysis of vacuum gas oils
    Rathbun, Wayne
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2007, 45 (10) : 636 - 642
  • [6] A robust thermal modulator for comprehensive two-dimensional gas chromatography
    Phillips, JB
    Gaines, RB
    Blomberg, J
    van der Wielen, FWM
    Dimandja, JM
    Green, V
    Granger, J
    Patterson, D
    Racovalis, L
    de Geus, HJ
    de Boer, J
    Haglund, P
    Lipsky, J
    Sinha, V
    Ledford, EB
    HRC-JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY, 1999, 22 (01): : 3 - 10
  • [7] Modulation-induced error in comprehensive two-dimensional gas chromatographic separations
    Harynuk, J. J.
    Kwong, A. H.
    Marriott, P. J.
    JOURNAL OF CHROMATOGRAPHY A, 2008, 1200 (01) : 17 - 27
  • [8] Prediction of comprehensive two-dimensional gas chromatographic separations - A theoretical and practical exercise
    Beens, J
    Tijssen, R
    Blomberg, J
    JOURNAL OF CHROMATOGRAPHY A, 1998, 822 (02) : 233 - 251
  • [9] COMPREHENSIVE TWO-DIMENSIONAL GAS CHROMATOGRAPHY USING A MEMS THERMAL MODULATOR
    Paul, D.
    Serrano, G.
    Zellers, E. T.
    Kurabayashi, K.
    2012 IEEE 25TH INTERNATIONAL CONFERENCE ON MICRO ELECTRO MECHANICAL SYSTEMS (MEMS), 2012,
  • [10] Thermal modulator array for analyte modulation and comprehensive two-dimensional gas chromatography
    Burger, BV
    Snyman, T
    Burger, WJG
    van Rooyen, WF
    JOURNAL OF SEPARATION SCIENCE, 2003, 26 (1-2) : 123 - 128