An automated system for 24-h monitoring of cough frequency: The Leicester cough monitor

被引:67
作者
Matos, Sergio [1 ]
Birring, Surinder S.
Pavord, Ian D.
Evans, David H.
机构
[1] Univ Hosp, Dept Med Phys, Leicester LE1 5WW, Leics, England
[2] Univ Leicester, Fac Med, Dept Cardiovasc Sci, Leicester LE1 5WW, Leics, England
[3] Glenfield Gen Hosp, Inst Lung Hlth, Dept Resp Med, Leicester LE3 9QP, Leics, England
关键词
algorithms; biomedical monitoring; biomedical signal detection; cough hidden Markov models; respiratory system;
D O I
10.1109/TBME.2007.900811
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The objective monitoring of cough for extended periods of time has long been recognized as an important step towards a better understanding of this symptom, and a better management of chronic cough patients. In this paper, we present a system for the automatic analysis of 24-h, continuous, ambulatory recordings of cough. The system uses audio recordings from. a miniature microphone and the detection algorithm is based on statistical models of the time-spectral characteristics of cough sounds. We validated the system against manual counts obtained by a trained observer on 40 ambulatory recordings and our results show a median sensitivity value of 85.7%, median positive predictive value of 94.7% and median false positive rate of 0.8 events/h. An analysis application was developed, with a graphical user interface, allowing the use of the system in clinical settings by technical or medical staff. The result of the analysis of a recording session is presented as a concise, graphical-based report. The modular nature of the system interface facilitates its enhancement with the integration of further modules.
引用
收藏
页码:1472 / 1479
页数:8
相关论文
共 21 条
[1]  
[Anonymous], 2002, CAMBRIDGE U ENG DEP
[2]   Cough frequency, cough sensitivity and health status in patients with chronic cough [J].
Birring, Surinder S. ;
Matos, Sergio ;
Patel, Ronnak B. ;
Prudon, Benjamin ;
Evans, David H. ;
Pavord, Ian D. .
RESPIRATORY MEDICINE, 2006, 100 (06) :1105-1109
[3]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[4]  
BRANDENBURG K, 2000, INTRO MPEG LAYER 3
[5]  
Chang AB, 2003, COUGH: CAUSES, MECHANISMS AND THERAPY, P57, DOI 10.1002/9780470755846.ch7
[6]   A new use for an old Holter monitor: An ambulatory cough meter [J].
Chang, AB ;
Newman, RG ;
Phelan, PD ;
Robertson, CF .
EUROPEAN RESPIRATORY JOURNAL, 1997, 10 (07) :1637-1639
[7]   Methods of assessing cough and antitussives in man [J].
Chung, KF .
PULMONARY PHARMACOLOGY & THERAPEUTICS, 1996, 9 (5-6) :373-377
[8]  
CHUNG KF, 2003, COUGH CAUSES MECH TH, P57
[9]  
COYLE MA, 2005, COUGH, V1
[10]   Impact of chronic cough on quality of life [J].
French, CL ;
Irwin, RS ;
Curley, FJ ;
Krikorian, CJ .
ARCHIVES OF INTERNAL MEDICINE, 1998, 158 (15) :1657-1661