Inter-rater reliability and test-retest reliability of the Performance and Fitness (PERF-FIT) test battery for children: a test for motor skill related fitness

被引:19
作者
Smits-Engelsman, Bouwien C. M. [1 ]
Smit, Eline [2 ]
Doe-Asinyo, Rosemary Xorlanyo [1 ,3 ]
Lawerteh, Stella Elikplim [1 ,4 ]
Aertssen, Wendy [2 ]
Ferguson, Gillian [1 ]
Jelsma, Dorothee L. [5 ]
机构
[1] Univ Cape Town, Dept Hlth & Rehabil Sci, Fac Hlth Sci, Cape Town, South Africa
[2] Univ Profess, Avansplus, Breda, Netherlands
[3] Univ Ghana, Dept Occupat Therapy, Coll Hlth Sci, Accra, Ghana
[4] 37 Mil Hosp, Dept Paediat, Accra, Ghana
[5] Univ Groningen, Dev & Clin Neuropsychol, Groningen, Netherlands
关键词
Reliability; Physical fitness; Skill-related physical fitness; Children; Low resourced settings; Psychometric properties; Motor development; DEVELOPMENTAL COORDINATION DISORDER; SHUTTLE RUN TEST; PHYSICAL-FITNESS; RECOMMENDATIONS; DEFINITIONS; ADOLESCENTS; CHILDHOOD; AGREEMENT; CONSENSUS; VALIDITY;
D O I
10.1186/s12887-021-02589-0
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Background: The Performance and Fitness (PERF-FIT) test battery for children is a recently developed, valid assessment tool for measuring motor skill-related physical fitness in 5 to 12-year-old children living in low-income settings. The aim of this study was to determine: (1) inter-rater reliability and (2) test-retest reliability of the PERF-FIT in children from 3 different countries (Ghana, South Africa and the Netherlands). Method: For inter-rater reliability 29 children, (16 boys and 13 girls, 6-10 years) were scored by 2 raters simultaneously. For test-retest reliability 72 children, (33 boys and 39 girls, 5-12 years) performed the test twice, minimally 1 week and maximally 2 weeks apart. Relative and absolute reliability indices were calculated. ANOVA was used to examine differences between the three assessor teams in the three countries. Results: The PERF-FIT demonstrated excellent inter-rater reliability (ICC, >= 0.80) and good test-retest reliability (ICC, 0.80) for 11 of the 12 tasks, with a poor ICC for the Jumping item, due to low spread in values. A significant difference between first and second test occasion was present on half of the items, but the differences were small (Cohen's d 0.01-0.17), except for Stepping, Side jump and Bouncing and Catching (Cohen's d 0.34, 0.41 and 0.33, respectively). Overall, measurement error, Limits of Agreement and Coefficient of Variation had acceptable levels to support clinical use. No systematic dissimilarities in error were found between first and second measurement between the three countries but for one item (Overhead throw). Conclusions: The PERF-FIT can reliably measure motor skill related fitness in 5 to 12-year-old children in different settings and help clinicians monitor levels of fundamental motor skills (throwing, bouncing, catching, jumping, hopping and balance), power and agility.
引用
收藏
页数:11
相关论文
共 50 条
[31]   Diagnostic interview for genetic studies (DIGS): inter-rater and test-retest reliability of alcohol and drug diagnoses [J].
Berney, A ;
Preisig, M ;
Matthey, ML ;
Ferrero, F ;
Fenton, BT .
DRUG AND ALCOHOL DEPENDENCE, 2002, 65 (02) :149-158
[32]   Evaluation of inter-rater and test-retest reliability for near-infrared spectroscopy reactive hyperemia measures [J].
McGranahan, Melissa J. ;
Kibildis, Samuel W. ;
McCully, Kevin K. ;
O'Connor, Patrick J. .
MICROVASCULAR RESEARCH, 2023, 148
[33]   Test-retest, inter- and intra-rater reliability of the flexicurve for evaluation of the spine in children [J].
Sedrez, Juliana A. ;
Candotti, Claudia T. ;
Rosa, Maria I. Z. ;
Medeiros, Fernanda S. ;
Marques, Mariana T. ;
Loss, Jefferson F. .
BRAZILIAN JOURNAL OF PHYSICAL THERAPY, 2016, 20 (02) :142-147
[34]   The test-retest reliability of a battery of new occupational performance assessments [J].
Ikiugu, Moses N. ;
Anderson, Angela ;
Manas, Diane .
INTERNATIONAL JOURNAL OF THERAPY AND REHABILITATION, 2008, 15 (12) :562-570
[35]   Excellent test-retest and inter-rater reliability for Tardieu Scale measurements with inertial sensors in elbow flexors of stroke patients [J].
Paulis, Winifred D. ;
Horemans, Herwin L. D. ;
Brouwer, Betty S. ;
Stam, Henk J. .
GAIT & POSTURE, 2011, 33 (02) :185-189
[36]   Test-Retest and Inter-Rater Reliability of a Rotary Axis Encoder-Flywheel System for the Assessment of Hip Rotation Exercises [J].
Lahuerta-Martin, Silvia ;
Esteban-Lozano, Elena ;
Jimenez-del-Barrio, Sandra ;
Robles-Perez, Roman ;
Mingo-Gomez, Maria Teresa ;
Ceballos-Laita, Luis ;
Hernando-Garijo, Ignacio .
APPLIED SCIENCES-BASEL, 2024, 14 (01)
[37]   Inter-rater and test-retest reliability of three contingent valuation question formats in south-east Nigeria [J].
Onwujekwe, O ;
Fox-Rushby, J ;
Hanson, K .
HEALTH ECONOMICS, 2005, 14 (05) :529-536
[38]   Test-Retest and Inter-Rater Reliability of Isokinetic Ankle Dorsiflexor and Plantar Flexor Strength Measurement in Healthy Adults [J].
Ozyemisci Taskiran, Ozden ;
Ozdodan, Vildan ;
Sepici, Vesile ;
Meray, Jale .
TURKIYE FIZIKSEL TIP VE REHABILITASYON DERGISI-TURKISH JOURNAL OF PHYSICAL MEDICINE AND REHABILITATION, 2013, 59 (01) :32-35
[39]   The inter-rater and test-retest reliability of skin thickness and skin elasticity measurements by the DermaLab Combo in healthy participants [J].
Peperkamp, Kirsten ;
Verhulst, Arico C. ;
Tielemans, Hanneke J. P. ;
Winters, Harm ;
van Dalen, Demi ;
Ulrich, Dietmar J. O. .
SKIN RESEARCH AND TECHNOLOGY, 2019, 25 (06) :787-792
[40]   Test-retest reliability and minimal detectable change scores of twelve functional fitness tests in adults with Down syndrome [J].
Boer, P. H. ;
Moss, S. J. .
RESEARCH IN DEVELOPMENTAL DISABILITIES, 2016, 48 :176-185