Inter-rater reliability and test-retest reliability of the Performance and Fitness (PERF-FIT) test battery for children: a test for motor skill related fitness

被引:17
|
作者
Smits-Engelsman, Bouwien C. M. [1 ]
Smit, Eline [2 ]
Doe-Asinyo, Rosemary Xorlanyo [1 ,3 ]
Lawerteh, Stella Elikplim [1 ,4 ]
Aertssen, Wendy [2 ]
Ferguson, Gillian [1 ]
Jelsma, Dorothee L. [5 ]
机构
[1] Univ Cape Town, Dept Hlth & Rehabil Sci, Fac Hlth Sci, Cape Town, South Africa
[2] Univ Profess, Avansplus, Breda, Netherlands
[3] Univ Ghana, Dept Occupat Therapy, Coll Hlth Sci, Accra, Ghana
[4] 37 Mil Hosp, Dept Paediat, Accra, Ghana
[5] Univ Groningen, Dev & Clin Neuropsychol, Groningen, Netherlands
关键词
Reliability; Physical fitness; Skill-related physical fitness; Children; Low resourced settings; Psychometric properties; Motor development; DEVELOPMENTAL COORDINATION DISORDER; SHUTTLE RUN TEST; PHYSICAL-FITNESS; RECOMMENDATIONS; DEFINITIONS; ADOLESCENTS; CHILDHOOD; AGREEMENT; CONSENSUS; VALIDITY;
D O I
10.1186/s12887-021-02589-0
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Background: The Performance and Fitness (PERF-FIT) test battery for children is a recently developed, valid assessment tool for measuring motor skill-related physical fitness in 5 to 12-year-old children living in low-income settings. The aim of this study was to determine: (1) inter-rater reliability and (2) test-retest reliability of the PERF-FIT in children from 3 different countries (Ghana, South Africa and the Netherlands). Method: For inter-rater reliability 29 children, (16 boys and 13 girls, 6-10 years) were scored by 2 raters simultaneously. For test-retest reliability 72 children, (33 boys and 39 girls, 5-12 years) performed the test twice, minimally 1 week and maximally 2 weeks apart. Relative and absolute reliability indices were calculated. ANOVA was used to examine differences between the three assessor teams in the three countries. Results: The PERF-FIT demonstrated excellent inter-rater reliability (ICC, >= 0.80) and good test-retest reliability (ICC, 0.80) for 11 of the 12 tasks, with a poor ICC for the Jumping item, due to low spread in values. A significant difference between first and second test occasion was present on half of the items, but the differences were small (Cohen's d 0.01-0.17), except for Stepping, Side jump and Bouncing and Catching (Cohen's d 0.34, 0.41 and 0.33, respectively). Overall, measurement error, Limits of Agreement and Coefficient of Variation had acceptable levels to support clinical use. No systematic dissimilarities in error were found between first and second measurement between the three countries but for one item (Overhead throw). Conclusions: The PERF-FIT can reliably measure motor skill related fitness in 5 to 12-year-old children in different settings and help clinicians monitor levels of fundamental motor skills (throwing, bouncing, catching, jumping, hopping and balance), power and agility.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Inter-rater reliability and test-retest reliability of the Performance and Fitness (PERF-FIT) test battery for children: a test for motor skill related fitness
    Bouwien C. M. Smits-Engelsman
    Eline Smit
    Rosemary Xorlanyo Doe-Asinyo
    Stella Elikplim Lawerteh
    Wendy Aertssen
    Gillian Ferguson
    Dorothee L. Jelsma
    BMC Pediatrics, 21
  • [2] Construct validity of the PERF-FIT, a test of motor skill-related fitness for children in low resource areas
    Smits-Engelsman, Bouwien
    Cavalcante Neto, Jorge Lopes
    Gomes Draghi, Tatiane Targino
    Rohr, Liz Araujo
    Jelsma, Dorothee
    RESEARCH IN DEVELOPMENTAL DISABILITIES, 2020, 102
  • [3] Inter-Rater and Test-Retest Reliability of the Sensory Integration Clinical Observations
    May-Benson, Teresa A.
    Teasdale, Alison
    PHYSICAL & OCCUPATIONAL THERAPY IN PEDIATRICS, 2021, 41 (01) : 74 - 84
  • [4] Emotional and Behavioral Screener: Test-Retest Reliability, Inter-Rater Reliability, and Convergent Validity
    Nordness, Philip D.
    Epstein, Michael H.
    Cullinan, Douglas
    Pierce, Corey D.
    REMEDIAL AND SPECIAL EDUCATION, 2014, 35 (04) : 211 - 217
  • [5] Test-retest reliability of the EUROFIT test battery: a review
    Grgic, Jozo
    SPORT SCIENCES FOR HEALTH, 2023, 19 (02) : 381 - 388
  • [6] Test-retest reliability of physical fitness tests among young athletes: The FITescola® battery
    Henriques-Neto, Duarte
    Minderico, Claudia
    Peralta, Miguel
    Marques, Adilson
    Sardinha, Luis B.
    CLINICAL PHYSIOLOGY AND FUNCTIONAL IMAGING, 2020, 40 (03) : 173 - 182
  • [7] Inter-rater and test-retest reliability of computerized clinical vestibular tools
    Cochrane, Graham D.
    Christy, Jennifer B.
    Kicker, Ethan T.
    Kailey, Ryan P.
    England, Brandon K.
    JOURNAL OF VESTIBULAR RESEARCH-EQUILIBRIUM & ORIENTATION, 2021, 31 (05): : 365 - 373
  • [8] Test-retest reliability of a battery of field-based health-related fitness measures for adolescents
    Lubans, David R.
    Morgan, Philip
    Callister, Robin
    Plotnikoff, Ronald C.
    Eather, Narelle
    Riley, Nicholas
    Smith, Chris J.
    JOURNAL OF SPORTS SCIENCES, 2011, 29 (07) : 685 - 693
  • [9] Test-Retest Reliability of Student-Administered Health-Related Fitness Tests in School Settings
    O'Keeffe, Brendan T.
    Donnelly, Alan E.
    MacDonncha, Ciaran
    PEDIATRIC EXERCISE SCIENCE, 2020, 32 (01) : 48 - 57
  • [10] Inter-rater and test-retest reliability: Methods and results for the neighborhood observational checklist
    Zenk, Shannon N.
    Schulz, Amy J.
    Mentz, Graciela
    House, James S.
    Gravlee, Clarence C.
    Miranda, Patricia Y.
    Miller, Patricia
    Kannan, Srimathi
    HEALTH & PLACE, 2007, 13 (02) : 452 - 465