Ultimate tensile strength of a Leeds-Keio/autograft ACL reconstruction utilizing PLLA tibial staple fixation

被引:6
作者
Field, JR
Hearn, TC
Costi, JJ
McGee, M
Costi, K
Adachi, N
Ochi, M
机构
[1] Flinders Univ S Australia, Repatriat Gen Hosp, Orthoped Unit, Daw Pk, SA 5041, Australia
[2] Royal Adelaide Hosp, Dept Orthopad & Trauma, Adelaide, SA, Australia
[3] Univ Adelaide, Adelaide, SA, Australia
[4] Shimane Med Univ, Dept Orthoped Surg, Izumo, Shimane, Japan
来源
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED | 2003年 / 34卷 / 05期
关键词
D O I
10.1016/S0020-1383(02)00012-8
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
An ovine model of anterior cruciate ligament reconstruction was utilized to evaluate the biomechanical and histological response of a polylactic acid tibial fixation staple (Gunze Ltd., Japan/Zimmer, Japan). This was performed in a comparison with metallic staples, currently utilized for this procedure. The prosthesis consisted of autograft combined with a Leeds-Keio (L-K) ligament. Early post-operative mobilization was followed by retrieval of specimens at 6, 12 and 24 weeks post-reconstruction. Evaluation of the mechanical characteristics of the graft reconstructions (tensile strength) showed no significant differences (P > 0.05) between the staple types for each time period. The histological response to the polylactic acid staple was minimal over the time period studied, with no adverse tissue reactions observed. The mode of reconstruction failure was observed to change with time (P < 0.05) presumably as the graft characteristics alter. Overall the absorbable staples performed at a comparable level with the metallic staples within the scope of the study. (C) 2002 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:334 / 342
页数:9
相关论文
共 30 条
  • [1] Initial fixation strength of polylactic acid interference screws in anterior cruciate ligament reconstruction
    Abate, JA
    Fadale, PD
    Hulstyn, MJ
    Walsh, WR
    [J]. ARTHROSCOPY, 1998, 14 (03): : 278 - 284
  • [2] ANTERIOR CRUCIATE LIGAMENT REPLACEMENT USING PATELLAR TENDON - AN EVALUATION OF GRAFT REVASCULARIZATION IN THE DOG
    ARNOCZKY, SP
    TARVIN, GB
    MARSHALL, JL
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1982, 64 (02) : 217 - 224
  • [3] BROWN CH, 1993, CLIN SPORT MED, V12, P723
  • [4] Quadrupled semitendinosus-gracilis autograft fixation in the femoral tunnel: A comparison between a metal and a bioabsorbable interference screw
    Caborn, DNM
    Coen, M
    Neef, R
    Hamilton, D
    Nyland, J
    Johnson, DL
    [J]. ARTHROSCOPY, 1998, 14 (03): : 241 - 245
  • [5] Comparative animal study of three ligament prostheses for the replacement of the anterior cruciate and medial collateral ligament
    Durselen, L
    Claes, L
    Ignatius, A
    Rubenacker, S
    [J]. BIOMATERIALS, 1996, 17 (10) : 977 - 982
  • [6] ABNORMALITY OF THE CONTRALATERAL LIGAMENT AFTER INJURIES OF THE MEDIAL COLLATERAL LIGAMENT - AN EXPERIMENTAL-STUDY IN RABBITS
    FRANK, CB
    LOITZ, B
    BRAY, R
    CHIMICH, D
    KING, G
    SHRIVE, N
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1994, 76A (03) : 403 - 412
  • [7] Current trends in anterior cruciate ligament reconstruction part 1: Biology and biomechanics of reconstruction
    Fu, FH
    Bennett, CH
    Lattermann, C
    Ma, CB
    [J]. AMERICAN JOURNAL OF SPORTS MEDICINE, 1999, 27 (06) : 821 - 830
  • [8] Pullout strength of tibial graft fixation in anterior cruciate ligament replacement with a patellar tendon graft: Interference screw versus staple fixation in human knees
    Gerich T.G.
    Cassim A.
    Lattermann C.
    Lobenhoffer H.P.
    [J]. Knee Surgery, Sports Traumatology, Arthroscopy, 1997, 5 (2) : 84 - 88
  • [9] Howell SM, 1996, J BONE JOINT SURG AM, V78A, P814
  • [10] THE OUTCOME OF A FREE AUTOGENOUS SEMITENDINOSUS TENDON GRAFT IN HUMAN ANTERIOR CRUCIATE RECONSTRUCTIVE SURGERY - A HISTOLOGICAL STUDY
    JOHNSON, LL