Utilising DXA for body composition research studies

被引:1
作者
Lee, Joseph C. [1 ,2 ]
Alghamry, Alaa [2 ,3 ]
机构
[1] Prince Charles Hosp, Dept Med Imaging, Chermside, Qld 4032, Australia
[2] Univ Queensland, Fac Med, Herston, Qld 4006, Australia
[3] Prince Charles Hosp, Internal Med Serv, Chermside, Qld 4032, Australia
关键词
Body composition; Research; Dual energy x-ray absorptiometry;
D O I
10.1016/j.bone.2021.115991
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
引用
收藏
页数:1
相关论文
共 10 条
  • [1] How important are BMD accuracy errors for the clinical interpretation of DXA scans?
    Blake, Glen M.
    Fogelman, Ignac
    [J]. JOURNAL OF BONE AND MINERAL RESEARCH, 2008, 23 (04) : 457 - 462
  • [2] Pitfalls in the measurement of muscle mass: a need for a reference standard
    Buckinx, Fanny
    Landi, Francesco
    Cesari, Matteo
    Fielding, Roger A.
    Visser, Marjolein
    Engelke, Klaus
    Maggi, Stefania
    Dennison, Elaine
    Al-Daghri, Nasser M.
    Allepaerts, Sophie
    Bauer, Jurgen
    Bautmans, Ivan
    Brandi, Maria Luisa
    Bruyere, Olivier
    Cederholm, Tommy
    Cerreta, Francesca
    Cherubini, Antonio
    Cooper, Cyrus
    Cruz-Jentoft, Alphonso
    McCloskey, Eugene
    Dawson-Hughes, Bess
    Kaufman, Jean-Marc
    Laslop, Andrea
    Petermans, Jean
    Reginster, Jean-Yves
    Rizzoli, Rene
    Robinson, Sian
    Rolland, Yves
    Rueda, Ricardo
    Vellas, Bruno
    Kanis, John A.
    [J]. JOURNAL OF CACHEXIA SARCOPENIA AND MUSCLE, 2018, 9 (02) : 269 - 278
  • [3] Does standardized BMD still remove differences between Hologic and GE-Lunar state-of-the-art DXA systems?
    Fan, B.
    Lu, Y.
    Genant, H.
    Fuerst, T.
    Shepherd, J.
    [J]. OSTEOPOROSIS INTERNATIONAL, 2010, 21 (07) : 1227 - 1236
  • [4] Frequently asked questions on measurement of bone mineral densitometry
    Lee, Joseph C.
    Loh, Nelson K.
    [J]. JOURNAL OF PRIMARY HEALTH CARE, 2012, 4 (03) : 259 - 261
  • [5] Standardization of spine and hip BMD measurements in different DXA devices
    Ozdemir, Aysegul
    Ucar, Murat
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2007, 62 (03) : 423 - 426
  • [6] Cross Calibration of Hologic QDR2000 and GE Lunar Prodigy for Whole Body Bone Mineral Density and Body Composition Measurements
    Pearson, Derek
    Horton, Barbara
    Green, Desmond J.
    [J]. JOURNAL OF CLINICAL DENSITOMETRY, 2011, 14 (03) : 294 - 301
  • [7] Dual energy X-ray absorptiometry: gold standard for muscle mass?
    Scafoglieri, Aldo
    Clarys, Jan Pieter
    [J]. JOURNAL OF CACHEXIA SARCOPENIA AND MUSCLE, 2018, 9 (04): : 786 - 787
  • [8] American Society for Parenteral and Enteral Nutrition Clinical Guidelines: The Validity of Body Composition Assessment in Clinical Populations
    Sheean, Patricia
    Gonzalez, M. Cristina
    Prado, Carla M.
    McKeever, Liam
    Hall, Amber M.
    Braunschweig, Carol A.
    [J]. JOURNAL OF PARENTERAL AND ENTERAL NUTRITION, 2020, 44 (01) : 12 - 43
  • [9] Body composition by DXA
    Shepherd, John A.
    Ng, Bennett K.
    Sommer, Markus J.
    Heymsfield, Steven B.
    [J]. BONE, 2017, 104 : 101 - 105
  • [10] DXA body composition corrective factors between Hologic Discovery models to conduct multicenter studies
    Sutter, Thibault
    Duboeuf, Francois
    Chapurlat, Roland
    Cortet, Bernard
    Lespessailles, Eric
    Roux, Jean-Paul
    [J]. BONE, 2021, 142