Noise characterization of supercontinuum sources for low-coherence interferometry applications

被引:42
作者
Brown, William J.
Kim, Sanghoon
Wax, Adam [1 ]
机构
[1] Duke Univ, Dept Biomed Engn, Durham, NC 27708 USA
基金
美国国家科学基金会; 美国国家卫生研究院;
关键词
LIGHT-SOURCE; TOMOGRAPHY;
D O I
10.1364/JOSAA.31.002703
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We examine the noise properties of supercontinuum light sources when used in low-coherence interferometry applications. The first application is a multiple-scattering low-coherence interferometry (ms2/LCI) system, where high power and long image acquisition times are required to image deep into tissue. For this system, we compare the noise characteristics of two supercontinuum sources from different suppliers. Both sources have long-term drift that limits the amount of time over which signal averaging is advantageous for reducing noise. The second application is a high-resolution optical coherence tomography system, where broadband light is needed for high axial resolution. For this system, we compare the noise performance of the two supercontinuum sources and a light source based on four superluminescent diodes (SLD) using imaging contrast as a comparative metric. We find that the NKT SuperK has superior noise performance compared with the Fianium SC-450-4, but neither meets the performance of the SLD. (C) 2014 Optical Society of America
引用
收藏
页码:2703 / 2710
页数:8
相关论文
共 20 条
[1]   Sensitivity advantage of swept source and Fourier domain optical coherence tomography [J].
Choma, MA ;
Sarunic, MV ;
Yang, CH ;
Izatt, JA .
OPTICS EXPRESS, 2003, 11 (18) :2183-2189
[2]   Fundamental noise limitations to supercontinuum generation in microstructure fiber [J].
Corwin, KL ;
Newbury, NR ;
Dudley, JM ;
Coen, S ;
Diddams, SA ;
Weber, K ;
Windeler, RS .
PHYSICAL REVIEW LETTERS, 2003, 90 (11) :4
[3]   Improved signal-to-noise ratio in spectral-domain compared with time-domain optical coherence tomography [J].
de Boer, JF ;
Cense, B ;
Park, BH ;
Pierce, MC ;
Tearney, GJ ;
Bouma, BE .
OPTICS LETTERS, 2003, 28 (21) :2067-2069
[4]   Supercontinuum sources in optical coherence tomography: A state of the art and the application to scan-free time domain correlation techniques and depth dependant dispersion compensation [J].
Froehly, L. ;
Meteau, J. .
OPTICAL FIBER TECHNOLOGY, 2012, 18 (05) :411-419
[5]   Parallel frequency-domain optical coherence tomography scatter-mode imaging of the hamster cheek pouch using a thermal light source [J].
Graf, R. N. ;
Brown, W. J. ;
Wax, A. .
OPTICS LETTERS, 2008, 33 (12) :1285-1287
[6]  
Izatt J., 1997, OPT PHOTON NEWS, V8, P41
[7]   Ultrahigh resolution optical coherence tomography imaging with a broadband superluminescent diode light source [J].
Ko, TH ;
Adler, DC ;
Fujimoto, JG ;
Mamedov, D ;
Prokhorov, V ;
Shidlovski, V ;
Yakubovich, S .
OPTICS EXPRESS, 2004, 12 (10) :2112-2119
[8]   Performance of fourier domain vs. time domain optical coherence tomography [J].
Leitgeb, R ;
Hitzenberger, CK ;
Fercher, AF .
OPTICS EXPRESS, 2003, 11 (08) :889-894
[9]   Deep tissue imaging using spectroscopic analysis of multiply scattered light [J].
Matthews, Thomas E. ;
Medina, Manuel ;
Maher, Jason R. ;
Levinson, Howard ;
Brown, William J. ;
Wax, Adam .
OPTICA, 2014, 1 (02) :105-111
[10]   Fourier domain multispectral multiple scattering low coherence interferometry [J].
Matthews, Thomas E. ;
Giacomelli, Michael G. ;
Brown, William J. ;
Wax, Adam .
APPLIED OPTICS, 2013, 52 (34) :8220-8228