Experimental Study on Seismic Behavior of Steel Frames with Infilled Recycled Aggregate Concrete Shear Walls

被引:7
|
作者
Sun, Lijian [1 ,2 ]
Guo, Hongchao [1 ,2 ]
Liu, Yunhe [1 ,2 ]
机构
[1] Xian Univ Technol, State Key Lab Ecohydraul Northwest Arid Reg, 5 Jinhua Rd, Xian 710048, Shaanxi, Peoples R China
[2] Xian Univ Technol, Sch Civil Engn & Architecture, 5 Jinhua Rd, Xian 710048, Shaanxi, Peoples R China
来源
APPLIED SCIENCES-BASEL | 2019年 / 9卷 / 21期
基金
中国国家自然科学基金;
关键词
steel frame; infilled shear walls; recycled aggregate concrete; semi-rigid connection; seismic behavior; BEAM-COLUMN JOINTS; DEMOLISHED CONCRETE; CYCLIC BEHAVIOR; STRENGTH; PERFORMANCE; TESTS;
D O I
10.3390/app9214723
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Experiments were performed on four specimens of steel frames with infilled recycled aggregate concrete shear walls (SFIRACSWs), one specimen of infilled ordinary concrete wall, and one pure-steel frame were conducted under horizontal low cyclic loading. The influence of the composite forms of steel frames and RACSWs (namely, infilled cast-in-place and infilled prefabricated) on the failure modes, transfer mechanisms of lateral force, bearing capacity, and ductility of SFIRACSWs is discussed, and the concrete type and connecting stiffness of beam-column joints (BCJs) are also considered. Test results showed that infilled RACSWs can increase the bearing capacity and lateral stiffness of SFIRACSWs. The connecting stiffness of BCJs slightly influences the seismic behavior of SFIRACSWs. In the infilled cast-in-place RACSWs, the wall cracks mainly extended along the diagonal direction. The bearing capacity was 2.4 times higher than in the pure steel frame, the initial stiffness was 4.3 times higher, and the displacement ductility factors were 2.44-2.69 times higher. In the infilled prefabricated RACSWs, the wall cracks mainly extended along the connection between the embedded T-shape connectors and walls before finally connecting along the horizontal direction. Moreover, shear failure occurred in the specimens. The bearing capacity was 1.44 times higher than that of the pure steel frame, the initial stiffness was 2.8 times higher, and the displacement ductility factors were 3.32-3.40 times higher. The degradation coefficients of the bearing capacity were more than 0.85, indicating that the specimens demonstrated a high safety reserve.
引用
收藏
页数:22
相关论文
共 50 条
  • [1] Experimental study on seismic behavior of recycled aggregate concrete infilled profile steel structures
    Jian Liu
    Qinpeng Yang
    Journal of the Brazilian Society of Mechanical Sciences and Engineering, 2024, 46
  • [2] Experimental study on seismic behavior of recycled aggregate concrete infilled profile steel structures
    Liu, Jian
    Yang, Qinpeng
    JOURNAL OF THE BRAZILIAN SOCIETY OF MECHANICAL SCIENCES AND ENGINEERING, 2024, 46 (04)
  • [3] Experimental study on seismic behavior of steel reinforced recycled aggregate concrete frame infilled with recycled aggregate concrete hollow blocks
    Xue, Jianyang
    Gao, Liang
    Luo, Zheng
    Lei, Siwei
    Liu, Fei
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2014, 35 (03): : 77 - 84
  • [4] Experimental study on seismic performance of resilient recycled aggregate concrete shear walls
    Zhang, Jianwei
    Yang, Hong
    Zhang, Man
    Liu, Xiao
    STRUCTURES, 2022, 41 : 36 - 50
  • [5] Seismic experiment and performance index studies on recycled aggregate concrete filled steel tube frames infilled with recycled hollow block filler walls
    Meng, Ercong
    Yu, Yalin
    Zhang, Xianggang
    Su, Yisheng
    STRUCTURAL CONCRETE, 2021, 22 (03) : 1327 - 1342
  • [6] Experimental study on the seismic behaviour of composite shear walls with stiffened steel plates and infilled concrete
    Zhang, Wenyuan
    Wang, Ke
    Chen, Yong
    Ding, Yukun
    THIN-WALLED STRUCTURES, 2019, 144
  • [7] Experimental study and theoretical analysis on steel frames infilled high-ductility concrete shear walls
    Qiu, Zhengtao
    Deng, Mingke
    Tian, Xinlong
    Li, Tong
    Sun, Hongzhe
    Cao, Jitao
    CONSTRUCTION AND BUILDING MATERIALS, 2024, 434
  • [8] Experimental study on seismic behavior of shear wall with cast-in-situ concrete infilled walls
    Zhou, Jian
    Tian, Chunyu
    Wang, Jun
    Wang, Lichao
    Ji, Wuxian
    Zhao, Depeng
    Pan, Binghong
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2022, 43 (08): : 86 - 99
  • [9] Experimental study on seismic behavior of mid-rise recycled concrete shear walls with different percentage of aggregate replacement
    Zhang, Jianwei
    Cao, Wanlin
    Dong, Hongying
    Zhu, Heng
    Tumu Gongcheng Xuebao/China Civil Engineering Journal, 2010, 43 (SUPPL. 2): : 55 - 61
  • [10] Seismic performance of carbonated recycled aggregate concrete shear walls
    Zhou, Yingwu
    Lin, Wenwei
    Hu, Rui
    Xing, Feng
    Guo, Menghuan
    Zhuang, Jiahao
    Xu, Wenzhuo
    CONSTRUCTION AND BUILDING MATERIALS, 2024, 443