Tibial component failure mechanisms in total knee arthroplasty

被引:483
|
作者
Berend, ME [1 ]
Ritter, MA [1 ]
Meding, JB [1 ]
Faris, PM [1 ]
Keating, EM [1 ]
Redelman, R [1 ]
Faris, GW [1 ]
Davis, KE [1 ]
机构
[1] St Francis Hosp, Ctr Hip & Knee Surg, Mooresville, IN USA
关键词
D O I
10.1097/01.blo.0000148578.22729.0e
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The purpose of this study was to examine the failure mechanisms and factors associated with failure of a nonmodular metal backed cemented tibial component. Out of 3152 total knee replacements done for osteoarthritis, 41 tibial components had been revised (1.3%). Four distinct failure mechanisms were identified: 20 knees were revised for medial bone collapse, 13 for ligamentous imbalance, 6 for progressive radiolucencies, and 2 for pain. Factors associated with medial bone collapse were varus tibial component alignment more than 3.0, Body Mass Index higher than 33.7, and overall postoperative varus limb alignment. Ligamentous imbalance was more prevalent in knees with preoperative valgus deformity. There were no knees revised for tibial component polyethylene wear or osteolysis. We conclude that the dominant failure mechanisms for this component design are related to preoperative deformity, technical factors of component alignment, overall limb alignment, and ligamentous imbalance.
引用
收藏
页码:26 / 34
页数:9
相关论文
共 50 条
  • [31] The All-Polyethylene Tibial Component in Primary Total Knee Arthroplasty
    Gioe, Terence J.
    Maheshwari, Aditya V.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2010, 92A (02): : 478 - 487
  • [32] Femoral and tibial component rotation in total knee arthroplasty METHODS AND CONSEQUENCES
    Scott, R. D.
    BONE & JOINT JOURNAL, 2013, 95B (11): : 140 - 143
  • [33] The accuracy of extramedullary guides for tibial component placement in total knee arthroplasty
    Chiu, K. Y.
    Yau, W. P.
    Ng, T. P.
    Tang, W. M.
    INTERNATIONAL ORTHOPAEDICS, 2008, 32 (04) : 467 - 471
  • [34] STABILITY OF INITIAL FIXATION OF THE TIBIAL COMPONENT IN CEMENTLESS TOTAL KNEE ARTHROPLASTY
    SHIMAGAKI, H
    BECHTOLD, JE
    SHERMAN, RE
    GUSTILO, RB
    JOURNAL OF ORTHOPAEDIC RESEARCH, 1990, 8 (01) : 64 - 71
  • [35] Ceramic coating improves tibial component fixation in total knee arthroplasty
    Regnér, L
    Carlsson, L
    Kärrholm, J
    Herberts, P
    JOURNAL OF ARTHROPLASTY, 1998, 13 (08): : 882 - 889
  • [36] FRACTURE OF POLYETHYLENE TIBIAL COMPONENT IN TOTAL KNEE ARTHROPLASTY DIAGNOSED BY ARTHROSCOPY
    HAVEL, PE
    GIDDINGS, JC
    ORTHOPEDICS, 1994, 17 (04) : 357 - 359
  • [37] The accuracy of extramedullary guides for tibial component placement in total knee arthroplasty
    K. Y. Chiu
    W. P. Yau
    T. P. Ng
    W. M. Tang
    International Orthopaedics, 2008, 32 : 467 - 471
  • [38] Catastrophic Failure of the Tibial Component After Total Knee Arthroplasty: Fracture and Dissociation Between the Baseplate and Stem
    Worgul, Christopher A.
    Lentine, Brandon
    Dicken, Quinten G.
    Freccero, David M.
    ARTHROPLASTY TODAY, 2022, 14 : 194 - 198
  • [39] Implant migration and failure in total knee arthroplasty is related to body mass index and tibial component size
    Berend, Michael E.
    Ritter, Merrill A.
    Hyldahl, Hans Christian
    Meding, John B.
    Redelman, Ryan
    JOURNAL OF ARTHROPLASTY, 2008, 23 (06): : 104 - 109
  • [40] Isolated Tibial Component Failure in Total Knee Arthroplasty: A Case Series Evaluating Inflammatory Response versus Mechanical Failure
    Yokhana, Sanar S.
    Bergum, Christopher
    Ren, Weiping
    Markel, David C.
    JOURNAL OF KNEE SURGERY, 2019, 32 (07) : 659 - 666