From patient-informed to patient-specific organ dose estimation in clinical computed tomography

被引:7
|
作者
Fu, Wanyi [1 ,2 ]
Segars, William P. [1 ,3 ,4 ]
Abadi, Ehsan [1 ,2 ]
Sharma, Shobhit [1 ,5 ]
Kapadia, Anuj J. [1 ,6 ]
Samei, Ehsan [1 ,2 ,3 ,4 ,5 ,6 ]
机构
[1] Duke Univ, Carl E Ravin Adv Imaging Labs, Durham, NC 27708 USA
[2] Duke Univ, Dept Elect & Comp Engn, Durham, NC 27708 USA
[3] Duke Univ, Dept Biomed Engn, Durham, NC 27706 USA
[4] Duke Univ, Dept Radiol, Durham, NC 27710 USA
[5] Duke Univ, Dept Phys, Durham, NC 27706 USA
[6] Duke Univ, Med Phys Grad Program, Durham, NC 27708 USA
来源
MEDICAL IMAGING 2018: PHYSICS OF MEDICAL IMAGING | 2018年 / 10573卷
基金
美国国家卫生研究院;
关键词
organ dose; Monte Carlo; computational phantom; patient-specific; convolutional neural networks; CT; PHANTOMS; ADULT;
D O I
10.1117/12.2294954
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Many hospitals keep a record of dose after each patient's CT scan to monitor and manage radiation risks. To facilitate risk management, it is essential to use the most relevant metric, which is the patient-specific organ dose. The purpose of this study was to develop and validate a patient-specific and automated organ dose estimation framework. This framework includes both patient and radiation exposure modeling. From patient CT images, major organs were automatically segmented using Convolutional Neural Networks (CNNs). Smaller organs and structures that were not otherwise segmented were automatically filled in by deforming a matched XCAT phantom from an existing library of models. The organ doses were then estimated using a validated Monte Carlo (PENELOPE) simulation. The segmentation and deformation components of the framework were validated independently. The segmentation methods were trained and validated using 50-patient CT datasets that were manually delineated. The deformation methods were validated using a leave-one-out technique across 50 existing XCAT phantoms that were deformed to create a patient-specific XCAT for each of 50 targets. Both components were evaluated in terms of dice similarity coefficients (DSC) and organ dose. For dose comparisons, a clinical chest-abdomen-pelvis protocol was simulated under fixed tube current (mA). The organ doses were estimated by a validated Monte Carlo package and compared between automated and manual segmentation and between patient-specific XCAT phantoms and their corresponding XCAT targets. Organ dose for phantoms from automated vs. manual segmentation showed a (similar to)2% difference, and organ dose for phantoms deformed by the study vs. their targets showed a variation of (similar to)5% for most organs. These results demonstrate the great potential to assess organ doses in a highly patient-specific manner.
引用
收藏
页数:6
相关论文
共 50 条
  • [41] A patient-specific hybrid phantom for calculating radiation dose and equivalent dose to the whole body
    Kollitz, Erika
    Han, Haegin
    Kim, Chan Hyeong
    Pinto, Marco
    Schwarz, Marco
    Riboldi, Marco
    Kamp, Florian
    Belka, Claus
    Newhauser, Wayne
    Dedes, George
    Parodi, Katia
    PHYSICS IN MEDICINE AND BIOLOGY, 2022, 67 (03)
  • [42] SURVEY OF PATIENT DOSE IN COMPUTED TOMOGRAPHY IN SYRIA 2009
    Kharita, M. H.
    Khazzam, S.
    RADIATION PROTECTION DOSIMETRY, 2010, 141 (02) : 149 - 161
  • [43] Patient-adapted organ absorbed dose and effective dose estimates in pediatric 18F-FDG positron emission tomography/computed tomography studies
    Quinn, Brian M.
    Gao, Yiming
    Mahmood, Usman
    Pandit-Taskar, Neeta
    Behr, Gerald
    Zanzonico, Pat
    Dauer, Lawrence T.
    BMC MEDICAL IMAGING, 2020, 20 (01)
  • [44] Machine learning-based estimation of patient body weight from radiation dose metrics in computed tomography
    Ichikawa, Hajime
    Ichikawa, Shota
    Sawane, Yasuhiro
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2024, 25 (09):
  • [45] Influence of patient-specific anatomy on medical computed tomography and risk evaluation of minimally invasive surgery at the otobasis
    Schieferbein, Vanessa
    Bredemann, Judith
    Schmitt, R.
    Stenin, I.
    Klenzner, T.
    Schipper, Joerg
    Kristin, Julia
    EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2019, 276 (02) : 375 - 382
  • [46] SWALLOWING COMPUTED TOMOGRAPHY: DOSE ESTIMATION IN A PHANTOM STUDY CONDUCTED AT VARIOUS PATIENT RECLINING ANGLES
    Kobayashi, Masanao
    Asada, Yasuki
    Matsubara, Kosuke
    Minami, Kazuyuki
    Suzuki, Shouichi
    Matsunaga, Yuta
    Haba, Tomonobu
    Kawaguchi, Ai
    Daioku, Tomihiko
    Toyama, Hiroshi
    Kato, Ryoichi
    RADIATION PROTECTION DOSIMETRY, 2018, 178 (01) : 87 - 94
  • [47] Image extrapolation for patient-specific CT dose determination based on scout images
    Liang, Qing
    DeWerd, Larry A.
    MEDICAL IMAGING 2013: PHYSICS OF MEDICAL IMAGING, 2013, 8668
  • [48] Dose assessment of the patient and the helper in emergency head computed tomography
    Chang, Rong-Chou
    Yu, Cheng-Ching
    Hsu, Fang-Yuh
    Chen, Tou-Rong
    Hsu, Shih-Ming
    Tyan, Yeu-Sheng
    RADIATION MEASUREMENTS, 2011, 46 (12) : 2048 - 2051
  • [49] Patient-specific predictions for clinical decision-making
    McGiffin, DC
    Naftel, DC
    Kirklin, JK
    AUSTRALIAN AND NEW ZEALAND JOURNAL OF SURGERY, 1997, 67 (2-3): : 108 - 114
  • [50] Patient-specific quality assurance strategies for synthetic computed tomography in magnetic resonance-only radiotherapy of the abdomen
    Dal Bello, Riccardo
    Lapaeva, Mariia
    La Greca Saint-Esteven, Agustina
    Wallimann, Philipp
    Gunther, Manuel
    Konukoglu, Ender
    Andratschke, Nicolaus
    Guckenberger, Matthias
    Tanadini-Lang, Stephanie
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2023, 27