From patient-informed to patient-specific organ dose estimation in clinical computed tomography

被引:7
|
作者
Fu, Wanyi [1 ,2 ]
Segars, William P. [1 ,3 ,4 ]
Abadi, Ehsan [1 ,2 ]
Sharma, Shobhit [1 ,5 ]
Kapadia, Anuj J. [1 ,6 ]
Samei, Ehsan [1 ,2 ,3 ,4 ,5 ,6 ]
机构
[1] Duke Univ, Carl E Ravin Adv Imaging Labs, Durham, NC 27708 USA
[2] Duke Univ, Dept Elect & Comp Engn, Durham, NC 27708 USA
[3] Duke Univ, Dept Biomed Engn, Durham, NC 27706 USA
[4] Duke Univ, Dept Radiol, Durham, NC 27710 USA
[5] Duke Univ, Dept Phys, Durham, NC 27706 USA
[6] Duke Univ, Med Phys Grad Program, Durham, NC 27708 USA
来源
MEDICAL IMAGING 2018: PHYSICS OF MEDICAL IMAGING | 2018年 / 10573卷
基金
美国国家卫生研究院;
关键词
organ dose; Monte Carlo; computational phantom; patient-specific; convolutional neural networks; CT; PHANTOMS; ADULT;
D O I
10.1117/12.2294954
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Many hospitals keep a record of dose after each patient's CT scan to monitor and manage radiation risks. To facilitate risk management, it is essential to use the most relevant metric, which is the patient-specific organ dose. The purpose of this study was to develop and validate a patient-specific and automated organ dose estimation framework. This framework includes both patient and radiation exposure modeling. From patient CT images, major organs were automatically segmented using Convolutional Neural Networks (CNNs). Smaller organs and structures that were not otherwise segmented were automatically filled in by deforming a matched XCAT phantom from an existing library of models. The organ doses were then estimated using a validated Monte Carlo (PENELOPE) simulation. The segmentation and deformation components of the framework were validated independently. The segmentation methods were trained and validated using 50-patient CT datasets that were manually delineated. The deformation methods were validated using a leave-one-out technique across 50 existing XCAT phantoms that were deformed to create a patient-specific XCAT for each of 50 targets. Both components were evaluated in terms of dice similarity coefficients (DSC) and organ dose. For dose comparisons, a clinical chest-abdomen-pelvis protocol was simulated under fixed tube current (mA). The organ doses were estimated by a validated Monte Carlo package and compared between automated and manual segmentation and between patient-specific XCAT phantoms and their corresponding XCAT targets. Organ dose for phantoms from automated vs. manual segmentation showed a (similar to)2% difference, and organ dose for phantoms deformed by the study vs. their targets showed a variation of (similar to)5% for most organs. These results demonstrate the great potential to assess organ doses in a highly patient-specific manner.
引用
收藏
页数:6
相关论文
共 50 条
  • [31] Patient-specific calibration of cone-beam computed tomography data sets for radiotherapy dose calculations and treatment plan assessment
    MacFarlane, Michael
    Wong, Daniel
    Hoover, Douglas A.
    Wong, Eugene
    Johnson, Carol
    Battista, Jerry J.
    Chen, Jeff Z.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2018, 19 (02): : 249 - 257
  • [32] Patient-specific lean body mass can be estimated from limited-coverage computed tomography images
    Devriese, Joke
    Beels, Laurence
    Maes, Alex
    van de Wiele, Christophe
    Pottel, Hans
    NUCLEAR MEDICINE COMMUNICATIONS, 2018, 39 (06) : 521 - 526
  • [33] Three-dimensional printing of patient-specific computed tomography lung phantoms: a reader study
    Shapira, Nadav
    Donovan, Kevin
    Mei, Kai
    Geagan, Michael
    Roshkovan, Leonid
    Gang, Grace J.
    Abed, Mohammed
    Linna, Nathaniel B.
    Cranston, Coulter P.
    O'Leary, Cathal N.
    Dhanaliwala, Ali H.
    Kontos, Despina
    Litt, Harold I.
    Stayman, J. Webster
    Shinohara, Russell T.
    Noel, Peter B.
    PNAS NEXUS, 2023, 2 (03):
  • [34] Patient-specific radiation dose and cancer risk estimation in CT: Part I. Development and validation of a Monte Carlo program
    Li, Xiang
    Samei, Ehsan
    Segars, W. Paul
    Sturgeon, Gregory M.
    Colsher, James G.
    Toncheva, Greta
    Yoshizumi, Terry T.
    Frush, Donald P.
    MEDICAL PHYSICS, 2011, 38 (01) : 397 - 407
  • [35] Learning patient-specific predictive models from clinical data
    Visweswaran, Shyam
    Angus, Derek C.
    Hsieh, Margaret
    Weissfeld, Lisa
    Yealy, Donald
    Cooper, Gregory F.
    JOURNAL OF BIOMEDICAL INFORMATICS, 2010, 43 (05) : 669 - 685
  • [36] Accuracy of patient dose estimation in cone beam computed tomography in breast irradiation by size-specific dose estimates with position correction
    Ueno, Hiroyuki
    Matsubara, Kosuke
    Bou, Sayuri
    Hizume, Masato
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2022, 23 (12):
  • [37] Accuracy of patient-specific organ dose estimates obtained using an automated image segmentation algorithm
    Schmidt, Taly Gilat
    Wang, Adam S.
    Coradi, Thomas
    Haas, Benjamin
    Star-Lack, Josh
    JOURNAL OF MEDICAL IMAGING, 2016, 3 (04)
  • [38] SIMPLE METHOD OF SIZE-SPECIFIC DOSE ESTIMATES CALCULATION FROM PATIENT WEIGHT ON COMPUTED TOMOGRAPHY
    Iriuchijima, Akiko
    Fukushima, Yasuhiro
    Nakajima, Takahito
    Tsushima, Yoshito
    Ogura, Akio
    RADIATION PROTECTION DOSIMETRY, 2018, 178 (02) : 208 - 212
  • [39] Patient-specific dose calculations for pediatric CT of the chest, abdomen and pelvis
    Susan D. Kost
    Nicholas D. Fraser
    Diana E. Carver
    David R. Pickens
    Ronald R. Price
    Marta Hernanz-Schulman
    Michael G. Stabin
    Pediatric Radiology, 2015, 45 : 1771 - 1780
  • [40] Patient-specific dose calculations for pediatric CT of the chest, abdomen and pelvis
    Kost, Susan D.
    Fraser, Nicholas D.
    Carver, Diana E.
    Pickens, David R.
    Price, Ronald R.
    Hernanz-Schulman, Marta
    Stabin, Michael G.
    PEDIATRIC RADIOLOGY, 2015, 45 (12) : 1771 - 1780