Voltammetric determination of adenosine and guanosine using fullerene-C60-modified glassy carbon electrode

被引:182
作者
Goyal, Rajendra N. [1 ]
Gupta, Vinod K.
Oyama, Munetaka
Bachheti, Neeta
机构
[1] Indian Inst Technol, Dept Chem, Roorkee 247667, Uttar Pradesh, India
[2] Kyoto Univ, Nishikyo Ku, Kyoto 6158520, Japan
关键词
fullerene-C-60-modified glassy carbon electrode; adenosine; guanosine; blood plasma; urine;
D O I
10.1016/j.talanta.2006.06.002
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A fullerene-C-60-modified glassy carbon electrode (GCE) is used for the simultaneous determination of adenosine and guanosine by differential pulse voltarnmetry. Compared to a bare glassy carbon electrode, the modified electrode exhibits an apparent shift of the oxidation potentials in the cathodic direction and a marked enhancement in the voltammetric peak current response for both the biornolecules. Linear calibration curves are obtained over the concentration range 0.5 mu M-1.0 mM in 0.1 M phosphate buffer solution at pH 7.2 with a detection limit of 3.02 x 10(-7) M and 1.45 x 10(-7) M for individual determination of adenosine and guanosine, respectively. The interference studies showed that the fullerene-C-60-modified glassy carbon electrode exhibited excellent selectivity in the presence of hypoxanthine, xanthine, uric acid and ascorbic acid. The proposed procedure was successfully applied to detect adenosine and guanosine in human blood plasma and urine, without any preliminary pre-treatment. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:1110 / 1117
页数:8
相关论文
共 25 条
  • [1] Chen Ying-Jie, 2003, Ai Zheng, V22, P537
  • [2] Christian G.D., 1962, JELECTROANAL CHEM, V3, P363, DOI [10.1016/0022-0728(62)80012-6, DOI 10.1016/0022-0728(62)80012-6]
  • [3] Electrochemical reactions of cytochrome c on electrodes modified by fullerene films
    Csiszár, M
    Szúcs, A
    Tölgyesi, M
    Mechler, A
    Nagy, JB
    Novák, M
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2001, 497 (1-2): : 69 - 74
  • [4] DUVAZ IN, 1989, CHROMATOGRAM, V10, P7
  • [5] A simple high-performance liquid chromatography assay for simultaneous measurement of adenosine, guanosine, and the oxypurine metabolites in plasma
    Feng, JDZ
    Yeung, PKF
    [J]. THERAPEUTIC DRUG MONITORING, 2000, 22 (02) : 177 - 183
  • [6] Nucleosides and ODN electrochemical detection onto boron doped diamond electrodes
    Fortin, E
    Chane-Tune, J
    Mailley, P
    Szunerits, S
    Marcus, B
    Petit, JP
    Mermoux, M
    Vieil, E
    [J]. BIOELECTROCHEMISTRY, 2004, 63 (1-2) : 303 - 306
  • [7] Frizzo MED, 2002, CELL MOL NEUROBIOL, V22, P353
  • [8] GEHRKE CW, 1984, CLIN LIQUID CHROMATO, V2, P139
  • [9] Simultaneous determination of purine nucleotides, their metabolites and β-nicotinamide adenine dinucleotide in cerebellar granule cells by ion-pair high performance liquid chromatography
    Giannattasio, S
    Gagliardi, S
    Samaja, M
    Marra, E
    [J]. BRAIN RESEARCH PROTOCOLS, 2003, 10 (03): : 168 - 174
  • [10] Voltammetric determination of atenolol at C60-modified glassy carbon electrodes
    Goyal, Rajendra N.
    Singh, Sudhanshu P.
    [J]. TALANTA, 2006, 69 (04) : 932 - 937