Acetone Measurements in the Exhaled Air by the Cavity Ring-Down Spectrometry

被引:0
|
作者
Revalde, G. [1 ,2 ]
Grundsteins, K. [2 ]
Abola, A. [2 ]
机构
[1] Riga Tech Univ, Inst Tech Phys, Dept Mat Sci & Appl Chem, P Valdena Str 3-7, Riga, Latvia
[2] Univ Latvia, Insitute Atom Phys & Spect, Jelgavas Str 3, Riga, Latvia
来源
BIOPHOTONICS-RIGA 2020 | 2020年 / 11585卷
关键词
Acetone; breath analysis; cavity ring-down spectroscopy; VOCs; BrAce; BREATH;
D O I
10.1117/12.2581987
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Our work is focused to develop sensitive optical diagnostic methods for the detection of Volatile Organic Compounds in the breath. For the breath measurements, we have built a cavity ring-down spectrometer, operated in the UV region. The system was tested and calibrated using a KinTek automated permeation tube system with nitrogen as a carrier gas, as well as self- prepared acetone mixtures in air with known concentrations. In this paper, we present results of the measurements of acetone concentration in the breath for the test group of randomly selected 40 people in the age group over 50. We observed the values of acetone concentration in the breath in the range from 0,1 - 80 ppm, with a median 7,1 ppm. The experiments showed that the limits of detection for acetone with the cavity ring-down system are several tens of ppb.
引用
收藏
页数:6
相关论文
共 50 条
  • [21] Open-Path Cavity Ring-Down Spectroscopy Sensors for Atmospheric Measurements
    Yalin, Azer P.
    McHale, Laura E.
    Shadman, Soran
    Rose, Charles
    2016 CONFERENCE ON LASERS AND ELECTRO-OPTICS (CLEO), 2016,
  • [22] Cavity ring-down spectroscopy measurements of sub-Doppler hyperfine structure
    Long, D. A.
    Havey, D. K.
    Okumura, M.
    Miller, C. E.
    Hodges, J. T.
    PHYSICAL REVIEW A, 2010, 81 (06):
  • [23] Direct detection of acetylene in air by continuous wave cavity ring-down spectroscopy
    Schmidt, F. M.
    Vaittinen, O.
    Metsala, M.
    Kraus, P.
    Halonen, L.
    APPLIED PHYSICS B-LASERS AND OPTICS, 2010, 101 (03): : 671 - 682
  • [24] Precise measurements of super-high reflectance with cavity ring-down technique
    Xiao, Shilei
    Li, Bincheng
    Wang, Jing
    METROLOGIA, 2020, 57 (05)
  • [25] Measurements of peroxy radicals using chemical amplification/cavity ring-down spectroscopy
    Zhang, Jingsong
    Liu, Yingdi
    Morales-Cueto, Rodrigo
    Hargrove, James
    Medina, David
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2009, 237 : 367 - 367
  • [26] Single-mode cavity ring-down spectroscopy for line shape measurements
    Looney, JP
    van Zee, RD
    Hodges, JT
    SPECTRAL LINE SHAPES, VOL 10: 14TH ICSLS, 1999, 467 : 275 - 285
  • [27] Direct detection of acetylene in air by continuous wave cavity ring-down spectroscopy
    F. M. Schmidt
    O. Vaittinen
    M. Metsälä
    P. Kraus
    L. Halonen
    Applied Physics B, 2010, 101 : 671 - 682
  • [28] Absorption Measurements in Liquid Core Waveguides Using Cavity Ring-Down Spectroscopy
    Bescherer, Klaus
    Barnes, Jack A.
    Loock, Hans-Peter
    ANALYTICAL CHEMISTRY, 2013, 85 (09) : 4328 - 4334
  • [29] Application of cavity ring-down spectroscopy in measurements of atmospheric trace species.
    Zhang, JS
    Wang, LM
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2002, 223 : U522 - U522
  • [30] Continuous wave cavity ring-down spectroscopy for velocity distribution measurements in plasma
    McCarren, D.
    Scime, E.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2015, 86 (10):