Development of a highly sensitive, field operable biosensor for serological studies of Ebola virus in central Africa

被引:34
作者
Petrosova, A.
Konry, T.
Cosnier, S.
Trakht, I.
Lutwama, J.
Rwaguma, E.
Chepurnov, A.
Muhlberger, E.
Lobel, L.
Marks, R. S. [1 ]
机构
[1] Ben Gurion Univ Negev, Fac Engn Sci, Dept Biotechnol Engn, IL-84105 Beer Sheva, Israel
[2] Ben Gurion Univ Negev, Dept Virol, Fac Hlth Sci, IL-84105 Beer Sheva, Israel
[3] Univ Grenoble 1, Lab Electrochim Organ & Photonchim Redox, Grenoble, France
[4] Columbia Univ, Dept Med, New York, NY 10032 USA
[5] Uganda Virus Res Inst, Dept Arbovirol Emerging & Reemerging Dis, Entebbe, Uganda
[6] Vector, Special Pathogens Unit, BSL 4 Lab, Novosibirsk, Russia
[7] Univ Marburg, Inst Virol, D-3550 Marburg, Germany
[8] Ben Gurion Univ Negev, Natl Inst Biotechnol, IL-84105 Beer Sheva, Israel
关键词
optical fibers; immunosensor; Ebola virus; poly(pyrrole-benzophenone); electropolymerization;
D O I
10.1016/j.snb.2006.07.005
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We describe herein a newly developed optical immunosensor for detection of antibodies directed against antigens of the Ebola virus strains Zaire and Sudan. We employed a photo immobilization methodology based on a photoactivatable clectrogenerated poly(pyrrole-benzophenone) film deposited upon an indium tin oxide (ITO) modified conductive surface fiber-optic. It was then linked to a biological receptor, Ebola virus antigen in this case, on the fiber tip through a light driven reaction. The photochemically modified optical fibers were tested as an immunosensor for detection of antibodies against Ebola virus, in animal and human sera, by use of a coupled chemiluminescent reaction. The immunosensor was tested for sensitivity, specificity, and compared to standard chemiluminescent ELISA under the same conditions. The analyte, anti-Ebola IgG, was detected at a low titer of 1:960,000 and 1: 1,000,000 for subtypes Zaire and Sudan, respectively. While the same serum tested by ELISA was one order (24 times) less sensitive. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:578 / 586
页数:9
相关论文
共 36 条
[1]  
[Anonymous], 2001, Wkly Epidemiol Rec, V76, P41
[2]   Prevalence of IgG antibodies to Ebola virus in individuals during an Ebola outbreak, Democratic Republic of the Congo, 1995 [J].
Busico, KM ;
Marshall, KL ;
Ksiazek, TG ;
Roels, TH ;
Fleerackers, Y ;
Feldmann, H ;
Khan, AS ;
Peters, CJ .
JOURNAL OF INFECTIOUS DISEASES, 1999, 179 :S102-S107
[3]  
Centers for Disease Control and Prevention (CDC), 2001, MMWR Morb Mortal Wkly Rep, V50, P73
[4]   TRANSPARENT CONDUCTORS - A STATUS REVIEW [J].
CHOPRA, KL ;
MAJOR, S ;
PANDYA, DK .
THIN SOLID FILMS, 1983, 102 (01) :1-46
[5]   An electrogenerated poly(pyrrole-benzophenone) film for the photografting of proteins [J].
Cosnier, S ;
Senillou, A .
CHEMICAL COMMUNICATIONS, 2003, (03) :414-415
[6]   Anthrax, tularemia, plague, ebola or smallpox as agents of bioterrorism: recognition in the emergency room [J].
Cunha, BA .
CLINICAL MICROBIOLOGY AND INFECTION, 2002, 8 (08) :489-503
[7]   Serological reactivity of baculovirus-expressed Ebola virus VP35 and nucleoproteins [J].
Groen, J ;
van den Hoogen, BG ;
Burghoorn-Maas, CP ;
Fooks, AR ;
Burton, J ;
Clegg, CJSC ;
Zeller, H ;
Osterhaus, ADME .
MICROBES AND INFECTION, 2003, 5 (05) :379-385
[8]   HEMORRHAGIC-FEVER VIRUS ACTIVITY IN EQUATORIAL AFRICA - DISTRIBUTION AND PREVALENCE OF FILOVIRUS REACTIVE ANTIBODY IN THE CENTRAL-AFRICAN-REPUBLIC [J].
JOHNSON, ED ;
GONZALEZ, JP ;
GEORGES, A .
TRANSACTIONS OF THE ROYAL SOCIETY OF TROPICAL MEDICINE AND HYGIENE, 1993, 87 (05) :530-535
[9]   CALCULATION OF THE FIGURE OF MERIT FOR INDIUM TIN OXIDE-FILMS BASED ON BASIC THEORY [J].
KNICKERBOCKER, SA ;
KULKARNI, AK .
JOURNAL OF VACUUM SCIENCE & TECHNOLOGY A-VACUUM SURFACES AND FILMS, 1995, 13 (03) :1048-1052
[10]   Physico-chemical studies of indium tin oxide-coated fiber optic biosensors [J].
Konry, T ;
Marks, RS .
THIN SOLID FILMS, 2005, 492 (1-2) :313-321