Open reduction internal fixation of displaced transverse patella fractures with figure-eight wiring through parallel cannulated compression screws

被引:112
|
作者
Berg, EE [1 ]
机构
[1] New Hampshire Bone & Joint Inst, Bedford, NH 03110 USA
关键词
patella fracture; internal fixation; cannulated screws;
D O I
10.1097/00005131-199711000-00005
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objective: To evaluate the clinical results of transverse patella fracture fixation with a tensioned anterior figure-eight wire placed through parallel cannulated screws. Design: Prospective, clinical. Patients: Ten patients with displaced transverse patella fractures were managed with a standardized rehabilitation protocol that employed early continuous passive knee motion. Outcome Measures: Time to clinical and radiographic union, Hospital for Special Surgery Knee Scores, and comparisons with literature cohort studies. Results: Clinical union occurred at an of average eight weeks and radiographic union at a mean of thirteen weeks postoperatively. Early continuous passive motion over a restricted are did not compromise the quality of fracture reduction, even though the majority of patients were elderly and had osteopenic bone. Subjective and functional results using Hospital for Special Surgery Knee Scores were comparable to previously published reports, with 70 percent achieving an excellent or good outcome. Conclusions: The described fixation technique for transverse patella fractures had clinical results equivalent to reports of patella fractures fixed with modified tension band wiring. Advantages included a low-profile construct that caused lesser degrees of implant irritation to local soft tissue structures, was compatible with the use of early restricted motion, and afforded a method to salvage three cases in which traditional tension band wiring failed to maintain an anatomic reduction in oteoporotic bone.
引用
收藏
页码:573 / 576
页数:4
相关论文
共 50 条
  • [11] Comparison of the outcomes of cannulated screws vs. modified tension band wiring fixation techniques in the management of mildly displaced patellar fractures
    Tao Lin
    Junbin Liu
    Baojun Xiao
    Dehao Fu
    Shuhua Yang
    BMC Musculoskeletal Disorders, 16
  • [12] Treatment of displaced transverse fractures of the patella: modified tension band wiring technique with or without augmented circumferential cerclage wire fixation
    Tien-Yu Yang
    Tsan-Wen Huang
    Po-Yao Chuang
    Kuo-Chin Huang
    BMC Musculoskeletal Disorders, 19
  • [13] Treatment of displaced transverse fractures of the patella: modified tension band wiring technique with or without augmented circumferential cerclage wire fixation
    Yang, Tien-Yu
    Huang, Tsan-Wen
    Chuang, Po-Yao
    Huang, Kuo-Chin
    BMC MUSCULOSKELETAL DISORDERS, 2018, 19
  • [14] Subtalar joint arthroscopic-assisted reduction and cannulated screw fixation versus open reduction and internal fixation for treating displaced intra-articular calcaneal fractures
    Yang, Hu
    Zhang, Shuo
    Zhong, Qigang
    Huai, Chaoyue
    Zhu, Nan
    Zhan, Junfeng
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2025, 20 (01):
  • [15] Biomechanical Research of Three Parallel Cannulated Compression Screws in Oblique Triangle Configuration for Fixation of Femoral Neck Unstable Fractures
    Zhang, Ru-Yi
    Zhang, Wu-Peng
    Yang, Guang-Min
    Wang, Dao-Feng
    Su, Peng
    Zhang, Yi
    Nie, Shao-Bo
    Li, Jia
    Zhao, Zhe
    Li, Jian-Tao
    Zhang, Li-Cheng
    Tang, Pei-Fu
    ORTHOPAEDIC SURGERY, 2024, 16 (04) : 953 - 964
  • [16] Closed Reduction and Percutaneous Kirschner Wire Fixation versus Open Reduction and Internal Fixation by Plate and Screws in Treatment Displaced Unstable Intra Articular Distal Radial Fractures
    Al-Fatlawy, Wejdi A.
    INTERNATIONAL JOURNAL OF MEDICAL RESEARCH & HEALTH SCIENCES, 2018, 7 (11): : 103 - 109
  • [17] Cyclic long-term loading of a bilateral fixed-angle plate in comparison with tension band wiring with K-wires or cannulated screws in transverse patella fractures
    Thelen, Simon
    Schneppendahl, Johannes
    Baumgaertner, Ralf
    Eichler, Christian
    Koebke, Juergen
    Betsch, Marcel
    Hakimi, Mohssen
    Windolf, Joachim
    Wild, Michael
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2013, 21 (02) : 311 - 317
  • [18] TOTAL HIP ARTHROPLASTY FOLLOWING OPEN REDUCTION AND INTERNAL FIXATION FOR DISPLACED ACETABULAR FRACTURES
    Veliceasa, B.
    Filip, A.
    Carp, C.
    Popescu, D.
    Gheorghevici, T. S.
    Pertea, Mihaela
    MEDICAL-SURGICAL JOURNAL-REVISTA MEDICO-CHIRURGICALA, 2021, 125 (03): : 435 - 442
  • [19] Functional and radiological outcomes in displaced heel fractures: Open reduction and internal fixation versus external fixation
    Ortu, Sebastiano
    Brusoni, Matteo
    Pisanu, Francesco
    Caggiari, Gianfilippo
    Ciurlia, Emanuele
    Bienati, Fabrizio
    Manunta, Andrea Fabio
    Doris, Carlo
    Manca, Mario
    ORTHOPEDIC REVIEWS, 2020, 12 (02) : 83 - 86
  • [20] Comparison of the Effect of Diameters and Numbers of Cannulated Screws and Headless Compression Screws on the Reduction Stability in Transverse Patellar Fractures: A Finite Element Model Study
    Ugur, Levent
    Karadeniz, Selami
    Yildiz, Aytac
    JOURNAL OF BIOMATERIALS AND TISSUE ENGINEERING, 2017, 7 (10) : 919 - 925