Solid dosage form analysis by near infrared spectroscopy: comparison of reflectance and transmittance measurements including the determination of effective sample mass

被引:25
|
作者
Iyer, M
Morris, HR
Drennen, JK [1 ]
机构
[1] Duquesne Univ, Grad Sch Pharmaceut Sci, Pharmaceut Sci Div, Pittsburgh, PA 15282 USA
[2] Carnegie Mellon Univ, Carnegie Mellon Res Inst, Pittsburgh, PA 15213 USA
关键词
near infrared; reflectance; transmittance; tablets; homogeneity; sample size;
D O I
10.1255/jnirs.340
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
Investigations into the near infrared analysis of intact tablets allow comparison of the reflectance and transmittance methodologies. The studies involved estimation of the effective sample mass and the effect of sample inhomogeneities. An empirical method for determining effective sample mass used tablets of varying thickness and constant compression force. Tablets containing a range of cimetidine concentrations were used to study the effect of drug concentration on effective sample mass as a function of wavelength of observation. Effective sampling depth was between 1.9 and 2.7 mm for reflectance measurements. With transmittance measurements, signal was completely attenuated when tablet thickness was greater than 3.4-4.9 mm, depending on the wavelength of observation. Multi-layered tablets provided a means of probing the effect of sample inhomogeneity. Both reflectance and transmittance measurements may be sensitive to sample inhomogeneity. Transmittance measurements are sensitive to pathlength variations.
引用
收藏
页码:233 / 245
页数:13
相关论文
共 9 条
  • [1] Comparison between transmittance and reflectance measurements in glucose determination using near infrared spectroscopy
    Jeon, KJ
    Hwang, ID
    Hahn, S
    Yoon, G
    JOURNAL OF BIOMEDICAL OPTICS, 2006, 11 (01)
  • [2] Pellet Coating Thickness Determination by Near-Infrared Reflectance Spectroscopy: Comparison of Two Reference Methods
    Muselik, Jan
    Dvorackova, Katerina
    Krejcova, Katerina
    Rabiskova, Miloslava
    Pazourek, Jiri
    Marton, Sylvia
    Drackova, Michaela
    Vorlova, Lenka
    CURRENT PHARMACEUTICAL ANALYSIS, 2010, 6 (04) : 225 - 233
  • [3] Near-Infrared Spectroscopy for the Analysis of Solid Dosage Forms: Does the Shell Influence Drug Identification Results?
    A. G. Gurzhieva
    T. E. Elizarova
    M. A. Morozova
    Pharmaceutical Chemistry Journal, 2016, 50 : 114 - 119
  • [4] NEAR-INFRARED SPECTROSCOPY FOR THE ANALYSIS OF SOLID DOSAGE FORMS: DOES THE SHELL INFLUENCE DRUG IDENTIFICATION RESULTS?
    Gurzhieva, A. G.
    Elizarova, T. E.
    Morozova, M. A.
    PHARMACEUTICAL CHEMISTRY JOURNAL, 2016, 50 (02) : 114 - 119
  • [5] Rapid In Situ Repeatable Analysis of Drugs in Powder Form Using Reflectance Near-Infrared Spectroscopy and Multivariate Calibration
    Melucci, Dora
    Monti, Dario
    D'Elia, Marcello
    Luciano, Giorgio
    JOURNAL OF FORENSIC SCIENCES, 2012, 57 (01) : 86 - 92
  • [6] Comparison of diffuse reflectance Fourier transform mid-infrared and near-infrared spectroscopy with grating-based near-infrared for the determination of fatty acids in forages
    Calderon, Francisco J.
    Reeves, James B., III
    Foster, Joyce G.
    Clapham, William M.
    Fedders, James M.
    Vigil, Merle F.
    Henry, William Brien
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2007, 55 (21) : 8302 - 8309
  • [7] Determination of the polymorphic forms of bicifadine hydrochloride by differential scanning calorimetry-thermogravimetric analysis, X-ray powder diffraction, attenuated total reflectance-infrared spectroscopy, and attenuated total reflectance-near-infrared spectroscopy
    McArdle, P
    Gilligan, K
    Cunningham, D
    Ryder, A
    APPLIED SPECTROSCOPY, 2005, 59 (11) : 1365 - 1371
  • [8] Determination of figures of merit for near-infrared and Raman spectrometry by net analyte signal analysis for a 4-component solid dosage system
    Short, Steven M.
    Cogdill, Robert P.
    Anderson, Carl A.
    AAPS PHARMSCITECH, 2007, 8 (04):
  • [9] Determination of figures of merit for near-infrared and raman spectrometry by net analyte signal analysis for a 4-component solid dosage system
    Steven M. Short
    Robert P. Cogdill
    Carl A. Anderson
    AAPS PharmSciTech, 8 (4)