Lung pathologies analyzed with multi-frequency electrical impedance tomography: Pilot animal study

被引:18
作者
Santos, Susana Aguiar [1 ]
Czaplik, Michael [2 ]
Orschulik, Jakob [1 ]
Hochhausen, Nadine [2 ]
Leonhardt, Steffen [1 ]
机构
[1] Rhein Westfal TH Aachen, Philips Chair Med Informat Technol, Aachen, Germany
[2] RWTH Aachen Univ Hosp, Dept Anesthesiol, Aachen, Germany
关键词
EIT; Lung monitoring; ARDS; Atelectasis; Lung edema; RESPIRATORY-DISTRESS SYNDROME; EIT; VENTILATION; SYSTEM; MODEL; FAILURE; WATER;
D O I
10.1016/j.resp.2018.03.016
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
In critically ill patients, correct diagnosis of lung disease is essential for successful therapy. Therefore, this study investigated whether new multi-frequency electrical impedance tomography (mfEIT) can detect, monitor and differentiate between pathologies associated with the acute respiratory distress syndrome (ARDS). For this pilot study, 12 pigs were randomized into an ARDS (bronchoalveolar lavage) group (n = 7) and a healthy control group (n = 5). Animals were monitored by means of mfEIT. In addition to functional images, a new impaired-ventilation (rIrnpVent) index was developed and frequency-difference images were computed and analyzed. Amplitude functional images revealed only small differences between the groups. However, phase functional images were of greater importance in distinguishing between lung pathologies. Correlation images showed substantial differences between the two groups. The new rImpVent index achieved high sensitivity (91%) and specificity (92%) in detecting PaO2/FiO(2) <= 200 mmHg. mfEIT was able to detect lung edema, differentiate this from atelectasis, and also monitor their progress over time in terms of global and regional differences.
引用
收藏
页码:1 / 9
页数:9
相关论文
共 35 条
[1]   GREIT: a unified approach to 2D linear EIT reconstruction of lung images [J].
Adler, Andy ;
Arnold, John H. ;
Bayford, Richard ;
Borsic, Andrea ;
Brown, Brian ;
Dixon, Paul ;
Faes, Theo J. C. ;
Frerichs, Inez ;
Gagnon, Herve ;
Gaerber, Yvo ;
Grychtol, Bartlomiej ;
Hahn, Guenter ;
Lionheart, William R. B. ;
Malik, Anjum ;
Patterson, Robert P. ;
Stocks, Janet ;
Tizzard, Andrew ;
Weiler, Norbert ;
Wolf, Gerhard K. .
PHYSIOLOGICAL MEASUREMENT, 2009, 30 (06) :S35-S55
[2]  
Aguiar Santos S., 2016, SENSORS, V16, P1158
[3]  
[Anonymous], 1996, COMPILATION DIELECTR
[4]  
[Anonymous], J PHYS C SER
[5]  
[Anonymous], 2006, NC3RS GUID PRIM ACC
[6]  
[Anonymous], 2012, JAMA-J AM MED ASSOC, V307, P2526
[7]   Bioimpedance tomography (Electrical impedance tomography) [J].
Bayford, R. H. .
ANNUAL REVIEW OF BIOMEDICAL ENGINEERING, 2006, 8 :63-91
[8]   Assessment of respiratory system compliance with electrical impedance tomography using a positive end-expiratory pressure wave maneuver during pressure support ventilation: a pilot clinical study [J].
Becher, Tobias H. ;
Bui, Simon ;
Zick, Guenther ;
Blaeser, Daniel ;
Schaedler, Dirk ;
Weiler, Norbert ;
Frerichs, Inez .
CRITICAL CARE, 2014, 18 (06)
[9]   Electrical impedance tomography measured at two thoracic levels can visualize the ventilation distribution changes at the bedside during a decremental positive end-expiratory lung pressure trial [J].
Bikker, Ido G. ;
Preis, Carsten ;
Egal, Mahamud ;
Bakker, Jan ;
Gommers, Diederik .
CRITICAL CARE, 2011, 15 (04)
[10]   First-time imaging of effects of inspired oxygen concentration on regional lung volumes and breathing pattern during hypergravity [J].
Borges, Joao Batista ;
Hedenstierna, Goran ;
Bergman, Jakob S. ;
Amato, Marcelo B. P. ;
Avenel, Jacques ;
Montmerle-Borgdorff, Stephanie .
EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2015, 115 (02) :353-363