Satisfaction with the Use of Different Technologies for Insulin Delivery and Glucose Monitoring Among Adults with Long-Standing Type 1 Diabetes and Problematic Hypoglycemia: 2-Year Follow-Up in the HypoCOMPaSS Randomized Clinical Trial

被引:13
作者
Speight, Jane [1 ,2 ,3 ]
Holmes-Truscott, Elizabeth [1 ,2 ]
Little, Stuart A. [4 ,5 ]
Leelarathna, Lalantha [6 ,7 ,8 ]
Walkinshaw, Emma [9 ]
Tan, Horn Kai [10 ]
Bowes, Anita [11 ]
Kerr, David [12 ]
Flanagan, Daniel [10 ]
Heller, Simon R. [9 ]
Evans, Mark L. [6 ]
Shaw, James A. M. [4 ,5 ]
机构
[1] Deakin Univ, Sch Psychol, Geelong, Vic, Australia
[2] Australian Ctr Behav Res Diabet, Diabet Victoria, 570 Elizabeth St, Melbourne, Vic 3000, Australia
[3] AHP Res, Hornchurch, England
[4] Newcastle Univ, Inst Cellular Med, Newcastle, NSW, Australia
[5] Newcastle Tyne Hosp NHS Fdn Trust, Newcastle Diabet Ctr, Newcastle Upon Tyne, Tyne & Wear, England
[6] Univ Cambridge, Wellcome Trust MRC Inst Metab Sci, Cambridge, England
[7] Manchester Univ NHS Fdn Trust, Manchester, Lancs, England
[8] Univ Manchester, Manchester, Lancs, England
[9] Univ Sheffield, Sch Med & Biomed Sci, Sheffield, S Yorkshire, England
[10] Peninsula Coll Med & Dent, Plymouth, Devon, England
[11] Poole Hosp NHS Fdn Trust, Poole Diabet Ctr, Poole, Dorset, England
[12] Sansum Diabet Res Inst, Santa Barbara, CA USA
关键词
Glucose monitoring; Hypoglycemia; Insulin delivery; Satisfaction; Technology; QUALITY-OF-LIFE; MELLITUS; IMPACT; PUMP;
D O I
10.1089/dia.2019.0152
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: In the HypoCOMPaSS trial, adults with long-standing type 1 diabetes and problematic hypoglycemia were randomized to compare insulin pump (continuous subcutaneous insulin infusion; CSII) with multiple daily injections (MDI) and real-time continuous glucose monitoring (RT-CGM) with conventional self-monitoring of blood glucose (SMBG). Our aim was to investigate participants' satisfaction with these technologies at 6-month randomized, controlled trial (RCT) endpoint and at 2-year follow-up. Methods: Participants completed the Insulin Treatment Satisfaction Questionnaire subscales "device delivery" and "hypoglycemia control"; and Glucose Monitoring Experience Questionnaire, assessing "convenience", "effectiveness", "intrusiveness", and "total satisfaction." We assessed change over time and between-group differences by insulin and monitoring modalities. Results: Participants (N = 96) were 64% women, aged 49 +/- 12 years, with a diabetes duration of 29 +/- 12 years. At 6 months, participants reported improvements compared with baseline (all P < 0.001) in satisfaction with insulin "delivery device" (r = 0.39) and "hypoglycemia control" (r = 0.52), and trends toward significance in perceived "effectiveness" (r = 0.42) and "intrusiveness" (r = 0.27) of monitoring device (but not "convenience", P = 0.139). All improvements were sustained at 2 years. At 6 months, the only difference between arms was that greater satisfaction with insulin "delivery device" was reported in the CSII group compared with MDI (P < 0.001, r = 0.40). No between-group differences were observed at 2 years. Conclusions: Overall, significant improvements in participant satisfaction with diabetes technologies were observed over the 6-month RCT, in all domains except "convenience," and maintained at 2 years. Although HypoCOMPaSS demonstrated noninferiority of SMBG versus CGM, and MDI versus CSII in terms of biomedical outcomes, detailed assessments confirm that participants' satisfaction with delivery device was greater in those allocated to CSII than MDI.
引用
收藏
页码:619 / 626
页数:8
相关论文
共 17 条
  • [1] Development and validation of the insulin treatment satisfaction questionnaire
    Anderson, RT
    Skovlund, SE
    Marrero, D
    Levine, DW
    Meadows, K
    Brod, M
    Balkrishnan, R
    [J]. CLINICAL THERAPEUTICS, 2004, 26 (04) : 565 - 578
  • [2] [Anonymous], 2017, BMJ-BRIT MED J, V356, pj963, DOI [10.1136/bmj.j963pmid:28254739, DOI 10.1136/bmj.j1285]
  • [3] Systematic literature review: quality of life associated with insulin pump use in Type 1 diabetes
    Barnard, K. D.
    Lloyd, C. E.
    Skinner, T. C.
    [J]. DIABETIC MEDICINE, 2007, 24 (06) : 607 - 617
  • [4] Bradley C., 1994, Handbook of Psychology and Diabetes, P111
  • [5] Evidence-Informed Clinical Practice Recommendations for Treatment of Type 1 Diabetes Complicated by Problematic Hypoglycemia
    Choudhary, Pratik
    Rickels, Michael R.
    Senior, Peter A.
    Vantyghem, Marie-Christine
    Maffi, Paola
    Kay, Thomas W.
    Keymeulen, Bart
    Inagaki, Nobuya
    Saudek, Frantisek
    Lehmann, Roger
    Hering, Bernhard J.
    [J]. DIABETES CARE, 2015, 38 (06) : 1016 - 1029
  • [6] Psychology, Technology, and Diabetes Management
    Gonder-Frederick, Linda A.
    Shepard, Jaclyn A.
    Grabman, Jesse H.
    Ritterband, Lee M.
    [J]. AMERICAN PSYCHOLOGIST, 2016, 71 (07) : 577 - 589
  • [7] Impact of continuous glucose monitoring on quality of life, treatment satisfaction, and use of medical care resources: analyses from the SWITCH study
    Hommel, E.
    Olsen, B.
    Battelino, T.
    Conget, I.
    Schuetz-Fuhrmann, I.
    Hoogma, R.
    Schierloh, U.
    Sulli, N.
    Gough, H.
    Castaneda, J.
    de Portu, S.
    Bolinder, J.
    [J]. ACTA DIABETOLOGICA, 2014, 51 (05) : 845 - 851
  • [8] Continuous Glucose Monitoring vs Conventional Therapy for Glycemic Control in Adults With Type 1 Diabetes Treated With Multiple Daily Insulin Injections The GOLD Randomized Clinical Trial
    Lind, Marcus
    Polonsky, William
    Hirsch, Irl B.
    Heise, Tim
    Bolinder, Jan
    Dahlqvist, Sofia
    Schwarz, Erik
    Olafsdottir, Arndis Finna
    Frid, Anders
    Wedel, Hans
    Ahlen, Elsa
    Nystrom, Thomas
    Hellman, Jarl
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2017, 317 (04): : 379 - 387
  • [9] Severe hypoglycaemia in type 1 diabetes mellitus: underlying drivers and potential strategies for successful prevention
    Little, S. A.
    Leelarathna, L.
    Barendse, S. M.
    Walkinshaw, E.
    Tan, H. K.
    Solomon, A. Lubina
    de Zoysa, N.
    Rogers, H.
    Choudhary, P.
    Amiel, S. A.
    Heller, S. R.
    Evans, M.
    Flanagan, D.
    Speight, J.
    Shaw, J. A. M.
    [J]. DIABETES-METABOLISM RESEARCH AND REVIEWS, 2014, 30 (03) : 175 - 190
  • [10] Comparison of Optimised MDI versus Pumps with or without Sensors in Severe Hypoglycaemia (the Hypo COMPaSS trial)
    Little, Stuart
    Chadwick, Thomas
    Choudhary, Pratik
    Brennand, Cath
    Stickland, Julia
    Barendse, Shalleen
    Olateju, Tolulope
    Leelarathna, Lalantha
    Walkinshaw, Emma
    Tan, Horng K.
    Marshall, Sally M.
    Thomas, Reena M.
    Heller, Simon
    Evans, Mark
    Kerr, David
    Flanagan, Daniel
    Speight, Jane
    Shaw, James A. M.
    [J]. BMC ENDOCRINE DISORDERS, 2012, 12