Respirator donning in post-hurricane New Orleans

被引:26
作者
Cummings, Kristin J.
Cox-Ganser, Jean
Riggs, Margaret A.
Edwards, Nicole
Kreiss, Kathleen
机构
[1] NIOSH, Morgantown, WV 26505 USA
[2] Ctr Dis Control & Prevent, Epidem Intelligence Serv, Atlanta, GA USA
[3] Natl Inst Occupat Safety & Hlth, Cincinnati, OH USA
关键词
D O I
10.3201/eid1305.061490
中图分类号
R392 [医学免疫学]; Q939.91 [免疫学];
学科分类号
100102 ;
摘要
We evaluated correctness of N95 filtering facepiece respirator donning by the public, in post-hurricane New Orleans, where respirators were recommended for mold remediation. We randomly selected, interviewed, and observed 538 participants, using multiple logistic regression for analysis. Only 129 (24%) participants demonstrated proper donning. Errors included nose clip not tightened (71%) and straps incorrectly placed (52%); 22% put on the respirator upside down. Factors independently associated with proper donning were as follows: ever having used a mask or respirator (odds ratio [OR] 5.28; 95% confidence interval [Cl], 1.79-22.64), ever having had a respirator fit test (OR 4.40; 95% Cl, 2.52-7.81); being male (OR 2.44; 95% Cl, 1.50-4.03); Caucasian race (OR 2.09; 95% Cl, 1.32-3.33); having a certified respirator (OR 1.99, 95% Cl, 1.20-3.28); and having participated in mold clean-up (OR 1.82; 95% Cl,1.00-3.41). Interventions to improve respirator donning should be considered in planning for influenza epidemics and disasters.
引用
收藏
页码:700 / 707
页数:8
相关论文
共 30 条
[1]  
ALFORD RH, 1966, P SOC EXP BIOL MED, V122, P800, DOI 10.3181/00379727-122-31255
[2]  
Dooley Samuel W., 2008, Morbidity and Mortality Weekly Report, V57, P1
[3]  
Biscotto CR, 2005, INT J TUBERC LUNG D, V9, P545
[4]   Transmission of influenza: Implications for control in health care settings [J].
Bridges, CB ;
Kuehnert, MJ ;
Hall, CB .
CLINICAL INFECTIOUS DISEASES, 2003, 37 (08) :1094-1101
[5]   Reducing respirator fit test errors: A multi-donning approach [J].
Campbell, DL ;
Coffey, CC ;
Jensen, PA ;
Zhuang, Z .
JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL HYGIENE, 2005, 2 (08) :391-399
[6]  
*CDCP, 2006, INT REC INF CONTR HL
[7]  
Chaovavanich Achara, 2004, Journal of the Medical Association of Thailand, V87, P1182
[8]   Fitting characteristics of eighteen N95 filtering-facepiece respirators [J].
Coffey, CC ;
Lawrence, RB ;
Campbell, DL ;
Zhuang, ZQ ;
Calvert, CA ;
Jensen, PA .
JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL HYGIENE, 2004, 1 (04) :262-271
[9]  
Crutchfield C D, 1999, Appl Occup Environ Hyg, V14, P827
[10]  
CUMMINGS KJ, 2006, ARCH ENVIRON OCCUP H, P61