Design of a natural draft air-cooled condenser and its heat transfer characteristics in the passive residual heat removal system for 10 MW molten salt reactor experiment

被引:14
作者
Zhao, Hangbin [1 ]
Yan, Changqi [1 ]
Sun, Licheng [1 ]
Zhao, Kaibin [2 ]
Fa, Dan [1 ]
机构
[1] Harbin Engn Univ, Natl Def Key Subject Lab Nucl Safety & Simulat Te, Harbin 150001, Peoples R China
[2] Hengtong Aviat Elect CO Ltd, Xian Aircraft Ind Grp, Xian 710089, Peoples R China
关键词
Natural draft; Air-cooled condenser; PRHRS; Molten salt reactor; POWER-PLANT; EXCHANGER;
D O I
10.1016/j.applthermaleng.2014.11.051
中图分类号
O414.1 [热力学];
学科分类号
摘要
As one of the Generation IV reactors, Molten Salt Reactor (MSR) has its superiorities in satisfying the requirements on safety. In order to improve its inherent safety, a concept of passive residual heat removal system (PRHRS) for the 10 MW Molten Salt Reactor Experiment (MSRE) was put forward, which mainly consisted of a fuel drain tank, a feed water tank and a natural draft air-cooled condenser (NDACC). Besides, several valves and pipes are also included in the PRHRS. A NDACC for the PRHRS was preliminarily designed in this paper, which contained a finned tube bundle and a chimney. The tube bundle was installed at the bottom of the chimney for increasing the velocity of the air across the bundle. The heat transfer characteristics of the NDACC were investigated by developing a model of the PRHRS using C++ code. The effects of the environmental temperature, finned tube number and chimney height on heat removal capacity of the NDACC were analyzed. The results show that it has sufficient heat removal capacity to meet the requirements of the residual heat removal for MSRE. The effects of these three factors are obvious. With the decay heat reducing, the heat dissipation power declines after a short-time rise in the beginning. The operation of the NDACC is completely automatic without the need of any external power, resulting in a high safety and reliability of the reactor, especially once the accident of power lost occurs to the power plant. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:423 / 434
页数:12
相关论文
共 25 条
[1]  
Akers W.W., 1959, Chemical Engineering Progress Symposium Series, V55, P171
[2]  
[Anonymous], 2002, US DOE NUCL EN RES A
[3]   Design of condensation heat exchanger for the PAFS (Passive Auxiliary Feedwater System) of APR plus (Advanced Power Reactor Plus) [J].
Bae, Byoung-Uhn ;
Yun, Byong-Jo ;
Kim, Seok ;
Kang, Kyoung Ho .
ANNALS OF NUCLEAR ENERGY, 2012, 46 :134-143
[4]  
BEALL S. E., 1964, Report No. ORNL-TM-732
[5]  
Briggs D.E., 1963, Chemical Engineering Progress Symposium Series, V59, P1
[6]  
Guymon R.H., 1973, Technical Report ORNL-TM-3039
[7]   Design of a passive residual heat removal system for the FUJI-233Um molten salt reactor system [J].
Ishiguro, T. ;
van Rooijen, W. F. G. ;
Shimazu, Y. ;
Mochizuki, H. .
ANNALS OF NUCLEAR ENERGY, 2014, 64 :398-407
[8]  
Iwamura T., 1995, PROGR NUCL ENERGY, V29, P397
[9]   Numerical study on pressure drop and heat transfer for designing sodium-to-air heat exchanger tube banks on advanced sodium-cooled fast reactor [J].
Kang, Hie-Chan ;
Eoh, Jae-Hyuk ;
Cha, Jae-Eun ;
Kim, Seong-O .
NUCLEAR ENGINEERING AND DESIGN, 2013, 254 :5-15
[10]   Numerical simulation of the emergency condenser of the SWR-1000 [J].
Krepper, E ;
Schaffrath, A ;
Aszódi, A .
NUCLEAR SCIENCE AND ENGINEERING, 2000, 135 (03) :267-279