Titanium dioxide nanoparticles in food: comparison of detection by triple-quadrupole and high-resolution ICP-MS in single-particle mode

被引:19
|
作者
Noireaux, Johanna [1 ]
Lopez-Sanz, Sara [2 ,3 ]
Vidmar, Janja [3 ]
Correia, Manuel [3 ]
Devoille, Laurent [4 ]
Fisicaro, Paola [1 ]
Loeschner, Katrin [3 ]
机构
[1] LNE, Dept Biomed & Inorgan Chem, Paris, France
[2] Univ Castilla La Mancha, Environm Sci Inst ICAM, Dept Analyt Chem & Food Technol, Avda Carlos III S-N, Toledo 45071, Spain
[3] Tech Univ Denmark, Natl Food Inst, Div Food Technol, Kemitorvet 201, DK-2800 Lyngby, Denmark
[4] LNE, Mat Dept, Trappes, France
关键词
Titanium dioxide; E171; Nanoparticles; Single-particle ICP-MS; Food; PLASMA-MASS SPECTROMETRY; TIO2; NANOPARTICLES; CONSUMER PRODUCTS; SIZE DISTRIBUTION; CHALLENGES; DEFINE; SAMPLE;
D O I
10.1007/s11051-021-05198-1
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
We used triple-quadrupole and high-resolution inductively coupled plasma-mass spectrometry (ICP-MS) in single-particle mode to characterize the food additive E171 (titanium dioxide, TiO2) in chewing gum, chocolate candy, and cake decoration in the same sample extracts. Then, we spiked TiO2 particles (with similar characteristics as E171) to milk as an example of a calcium-rich matrix. The obtained particle size distributions with both techniques were highly similar in terms of shape and median and mean diameters. Median diameters were in the range of 123 to 209 nm and mean diameters from 146 to 223 nm. In addition, they were in agreement with results obtained by scanning electron microscopy and asymmetric flow field-flow fractionation coupled to multi-angle light scattering and ICP-MS. Repeatable determination of number-based particle size distributions was possible with both ICP-MS techniques even in a calcium-rich matrix showing that both instruments were similarly efficient in resolving the Ca interferences. The combination of spICP-MS with microscopy and TiO2 recovery allowed validating the methods and identifying the presence of aggregated/agglomerated particles in one sample. For the TiO2 powder and the two remaining food products, recoveries were higher than 60%. Both instruments are fit for purpose even if the analyses were performed with differences in detector mode, dwell times, and calculation tools. This shows that both techniques may be used as long as operating conditions are optimized and applicability range is defined.
引用
收藏
页数:14
相关论文
共 50 条
  • [21] Spectral interferences in the analysis of cadmium in human blood by ICP-MS: comparison between high resolution sector field ICP-MS and quadrupole ICP-MS
    Vrijens, Jan
    Couck, Pedro
    Schroijen, Carmen
    Baeyens, Willy
    Leermakers, Martine
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2011, 26 (09) : 1819 - 1826
  • [22] Atomic Perspectives Single-Particle ICP-MS: A Key Analytical Technique for Characterizing Nanoparticles
    Stephan, Chady
    Thomas, Robert
    SPECTROSCOPY, 2017, 32 (03) : 12 - 25
  • [23] Detection and characterization of silver nanoparticles in chicken meat by asymmetric flow field flow fractionation with detection by conventional or single particle ICP-MS
    Loeschner, Katrin
    Navratilova, Jana
    Kobler, Carsten
    Molhave, Kristian
    Wagner, Stephan
    von der Kammer, Frank
    Larsen, Erik H.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2013, 405 (25) : 8185 - 8195
  • [24] Single-Particle ICP-MS/MS Application for Routine Screening of Nanoparticles Present in Powder-Based Facial Cosmetics
    Hebert, Deja
    Nelson, Jenny
    Diehl, Brooke N.
    Zito, Phoebe
    NANOMATERIALS, 2023, 13 (19)
  • [25] Detection and characterization of silver nanoparticles in chicken meat by asymmetric flow field flow fractionation with detection by conventional or single particle ICP-MS
    Katrin Loeschner
    Jana Navratilova
    Carsten Købler
    Kristian Mølhave
    Stephan Wagner
    Frank von der Kammer
    Erik H. Larsen
    Analytical and Bioanalytical Chemistry, 2013, 405 : 8185 - 8195
  • [26] Measurement of CeO2 Nanoparticles in Natural Waters Using a High Sensitivity, Single Particle ICP-MS
    Jreije, Ibrahim
    Azimzada, Agil
    Hadioui, Madjid
    Wilkinson, Kevin J.
    MOLECULES, 2020, 25 (23):
  • [27] Occurrence and Origins of Cerium Dioxide and Titanium Dioxide Nanoparticles in the Loire River (France) by Single Particle ICP-MS and FEG-SEM Imaging
    Phalyvong, Karine
    Sivry, Yann
    Pauwels, Helene
    Gelabert, Alexandre
    Tharaud, Mickael
    Wille, Guillaume
    Bourrat, Xavier
    Benedetti, Marc F.
    FRONTIERS IN ENVIRONMENTAL SCIENCE, 2020, 8
  • [28] Detection of TiO2 Nanoparticles in Municipal Sewage Treatment Plant and Their Characterization Using Single Particle ICP-MS
    Siva Prasad Bitragunta
    Sankar Ganesh Palani
    Anil Gopala
    Santosh Kumar Sarkar
    Venugopal Reddy Kandukuri
    Bulletin of Environmental Contamination and Toxicology, 2017, 98 : 595 - 600
  • [29] Simultaneous multi-element and multi-isotope detection in single-particle ICP-MS analysis: Principles and applications
    Tian, Xiangwei
    Jiang, Haowen
    Hu, Ligang
    Wang, Meng
    Cui, Wenbin
    Shi, Jianbo
    Liu, Guangliang
    Yin, Yongguang
    Cai, Yong
    Jiang, Guibin
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2022, 157
  • [30] Evaluation of collision/reaction gases in single-particle ICP-MS for sizing selenium nanoparticles and assessment of their antibacterial activity
    Freire, Bruna Moreira
    Cavalcanti, Yasmin Tavares
    Lange, Camila Neves
    Pieretti, Joana Claudio
    Pereira, Rodrigo Mendes
    Goncalves, Marcelly Chue
    Nakazato, Gerson
    Seabra, Amedea Barozzi
    Batista, Bruno Lemos
    NANOTECHNOLOGY, 2022, 33 (35)