Design, metallurgical features, mechanical performance and canal preparation of six reciprocating instruments

被引:44
作者
Martins, J. N. R. [1 ,2 ,3 ]
Silva, E. J. N. L. [4 ,5 ]
Marques, D. [2 ,3 ,6 ]
Belladonna, F. [5 ]
Simoes-Carvalho, M. [5 ]
Vieira, V. T. L. [4 ]
Antunes, H. S. [4 ]
Fernandes, F. M. B. [7 ]
Versiani, M. A. [8 ]
机构
[1] Univ Lisbon, Fac Med Dent, Dept Endodont, Lisbon, Portugal
[2] Univ Lisbon, Fac Med Dent, Unidade Invest Ciencias Orais & Biomed UICOB, Lisbon, Portugal
[3] Univ Lisbon, Fac Med Dent, Ctr Estudo Med Dent Baseada Evidencia CEMDBE, Lisbon, Portugal
[4] Grande Rio Univ UNIGRANRIO, Sch Dent, Dept Endodont, Rio De Janeiro, Brazil
[5] Fluminense Fed Univ, Dept Endodont, Niteroi, RJ, Brazil
[6] LIBPhys FCT UID FIS 04559 2013, Lisbon, Portugal
[7] Univ NOVA Lisboa, NOVA Sch Sci & Technol, Dept Mat Sci, CENIMAT I3N, Caparica, Portugal
[8] Brazilian Mil Police, Dent Specialty Ctr, Belo Horizonte, MG, Brazil
关键词
bending load; cyclic fatigue; differential scanning calorimetry; micro‐ CT; reciprocation; torsional strength;
D O I
10.1111/iej.13529
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Aim To compare six reciprocating instruments regarding their geometric design, metallurgical characteristics, mechanical behaviour and ability to prepare root canals. Methodology A total of 246 new 25-mm NiTi instruments (41 per group) from six reciprocating systems (Reciproc, Reciproc Blue, One Files, One Files Blue, Reverso Silver, and WaveOne Gold) were evaluated throughout a multimethod approach regarding their design using stereomicroscopy (number of blades and helix angle) and scanning electron microscopy (blades symmetry, cross section and surface finishing), nickel-titanium composition, phase transformation temperatures, mechanical performance (cyclic fatigue, torsional and bending resistance) and unprepared canal surface area on anatomically matched mandibular molars assessed by micro-CT. One-way ANOVA and post hoc Tukey's or Mood's median tests were selected depending on sample distribution with significance level set at 5%. Results The instruments had similarities regarding their metal composition and unprepared canal area, whilst differences in phase transformation temperatures and geometric design (number of blades, surface finishing and tip geometry) were observed. Overall, no difference was observed regarding the maximum torque values (P > 0.05), whilst One Files (72 s) and One Files Blue (414 s) had the shortest and longest times to fracture, respectively (P < 0.05). Similar angles of rotation were observed in Reciproc (310 degrees), One Files (285 degrees) and Reverso Silver (318 degrees) instruments (P > 0.05), which were significantly lower than Reciproc Blue (492 degrees), One Files Blue (456 degrees) and WaveOne Gold (492 degrees; P < 0.05). Maximum bending load demonstrated that Reciproc Blue (201.3 gf) was significantly more flexible that the other instruments (P < 0.05). Conclusion Although there were similarities in metal composition and percentage of unprepared canal surface, the instruments had differences in the overall geometric design, phase transformation temperatures and in the four mechanical resistance parameters (time to fracture, maximum torque, angle of rotation and maximum bending load).
引用
收藏
页码:1623 / 1637
页数:15
相关论文
共 38 条
[1]   Comparison of Cyclic Fatigue Resistance of 5 Heat-treated Nickel-titanium Reciprocating Systems in Canals with Single and Double Curvatures [J].
Al-Obaida, Mohammad, I ;
Merdad, Khalid ;
Alanazi, Mohammed S. ;
Altwaijry, Hesham ;
AlFaraj, Mohammad ;
Alkhamis, Ali A. ;
Al-Madi, Ebtissam M. .
JOURNAL OF ENDODONTICS, 2019, 45 (10) :1237-1241
[2]   Influence of the Preparation Order in Four-Canal Maxillary Molars with WaveOne Gold System [J].
Alberton, Carlla Sloane ;
Fagundes Tomazinho, Flavia Sens ;
Calefi, Pedro Souza ;
Hungaro Duarte, Marco Antonio ;
Vivan, Rodrigo Ricci ;
Baratto-Filho, Flares .
JOURNAL OF ENDODONTICS, 2020, 46 (09) :1291-1296
[3]   Fracture resistance of electropolished rotary nickel-titanium endodontic instruments [J].
Anderson, Margot E. ;
Price, John W. H. ;
Parashos, Peter .
JOURNAL OF ENDODONTICS, 2007, 33 (10) :1212-1216
[4]  
[Anonymous], 1986, CONCEPTUAL PROCEDURA
[5]  
[Anonymous], 2008, ISO 3630 36312008
[6]  
ASTM International, 2004, ASTM F2004 17 STANDA
[7]   Torsional fatigue and endurance limit of a size 30.06 ProFile rotary instrument [J].
Best, S ;
Watson, P ;
Pilliar, R ;
Kulkarni, GGK ;
Yared, G .
INTERNATIONAL ENDODONTIC JOURNAL, 2004, 37 (06) :370-373
[8]   Fatigue testing of a NiTi rotary instrument. Part 2: fractographic analysis [J].
Cheung, G. S. P. ;
Darvell, B. W. .
INTERNATIONAL ENDODONTIC JOURNAL, 2007, 40 (08) :619-625
[9]   Fatigue testing of a NiTi rotary instrument. Part 1: Strain-life relationship [J].
Cheung, G. S. P. ;
Darvell, B. W. .
INTERNATIONAL ENDODONTIC JOURNAL, 2007, 40 (08) :612-618
[10]   Evidence for Reduced Fatigue Resistance of Contemporary Rotary Instruments Exposed to Body Temperature [J].
de Vasconcelos, Rafaela Andrade ;
Murphy, Sarah ;
Talge Carvalho, Claudio Antonio ;
Govindjee, Rajiv G. ;
Govindjee, Sanjay ;
Peters, Ove A. .
JOURNAL OF ENDODONTICS, 2016, 42 (05) :782-787