Determination of clonixin in plasma and urine by reversed-phase high-performance liquid chromatography

被引:4
|
作者
Bica, A
Farinha, A
Blume, H
Barbosa, CM
机构
[1] Lab Estudos Farmaceut, P-1400 Lisbon, Portugal
[2] Univ Frankfurt, Frankfurt, Germany
[3] Univ Porto, Fac Farm, CTMUP, Porto, Portugal
[4] CETMED, Ctr Tecnol Medicamento, Porto, Portugal
关键词
validation; clonixin; nonsteroidal anti-inflammatory drugs;
D O I
10.1016/S0021-9673(00)00348-4
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A reversed-phase high-performance liquid chromatographic method that enables the determination of clonixin in human plasma and urine samples is described. Recovery of the drug was over 87.6 and 80.7% for plasma and urine, respectively. The limit of quantitation of the method was established as 10 ng/ml in plasma and 20 ng/ml in urine samples, with RSDs of less than 11.1%. The applicability of the method was further assessed by determining the plasma concentrations time course of clonixin in six healthy volunteers after single oral dose administration of 150 and 300 mg of clonixin and Clonix, (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:135 / 141
页数:7
相关论文
共 50 条
  • [1] DETERMINATION OF INULIN IN PLASMA AND URINE BY REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    DALLAMICO, R
    MONTINI, G
    PISANELLO, L
    PIOVESAN, G
    BOTTARO, S
    CRACCO, AT
    ZACCHELLO, G
    ZACCHELLO, F
    JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1995, 672 (01): : 155 - 159
  • [2] DETERMINATION OF CODEINE IN PLASMA AND URINE BY REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    STUBBS, RJ
    CHIOU, R
    BAYNE, WF
    JOURNAL OF CHROMATOGRAPHY, 1986, 377 : 447 - 453
  • [3] DETERMINATION OF PEMOLINE IN PLASMA, URINE AND TISSUES BY REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    AOYAMA, T
    KOTAKI, H
    SAITOH, Y
    NAKAGAWA, F
    JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1988, 430 (02): : 351 - 360
  • [4] Determination of linezolid in plasma by reversed-phase high-performance liquid chromatography
    Peng, GW
    Stryd, RP
    Murata, S
    Igarashi, M
    Chiba, K
    Aoyama, H
    Aoyama, M
    Zenki, T
    Ozawa, N
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1999, 20 (1-2) : 65 - 73
  • [5] DETERMINATION OF MECILLINAM IN URINE BY REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    STROJNY, N
    DESILVA, JAF
    JOURNAL OF CHROMATOGRAPHY, 1980, 181 (02): : 272 - 281
  • [6] IMPROVED METHOD FOR THE DETERMINATION OF INDOMETHACIN IN PLASMA AND URINE BY REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    STUBBS, RJ
    SCHWARTZ, MS
    CHIOU, R
    ENTWISTLE, LA
    BAYNE, WF
    JOURNAL OF CHROMATOGRAPHY, 1986, 383 (02): : 432 - 437
  • [7] DETERMINATION OF PLASMA OXALATE BY REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    JEREZ, E
    REVISTA ESPANOLA DE FISIOLOGIA, 1986, 42 (04): : 441 - 447
  • [8] THE DETERMINATION OF BROMAZEPAM IN PLASMA BY REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    LESOLLEU, H
    DEMOTESMAINARD, F
    VINCON, G
    BANNWARTH, B
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1993, 11 (08) : 771 - 775
  • [9] DETERMINATION OF VIGABATRIN IN PLASMA BY REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    TSANACLIS, LM
    WICKS, J
    WILLIAMS, J
    RICHENS, A
    THERAPEUTIC DRUG MONITORING, 1991, 13 (03) : 251 - 253
  • [10] DETERMINATION OF ANTIPYRINE IN PLASMA BY REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    CAMPBELL, TM
    MURDAUGH, EW
    KILLENBERG, PG
    JOURNAL OF CHROMATOGRAPHY, 1979, 163 (02): : 236 - 238