Harmonic power Doppler contrast echocardiography: Preliminary experimental results

被引:8
作者
Agrawal, DI [1 ]
Malhotra, S [1 ]
Nanda, NC [1 ]
Truffa, CC [1 ]
Agrawal, G [1 ]
Thakur, AC [1 ]
Jamil, F [1 ]
Taylor, GW [1 ]
Becher, H [1 ]
机构
[1] Univ Alabama, Div Cardiovasc Dis, Birmingham, AL 35233 USA
来源
ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES | 1997年 / 14卷 / 06期
关键词
harmonic imaging; power Doppler M-mode; harmonic power Doppler imaging; contrast echocardiography; Levovist;
D O I
10.1111/j.1540-8175.1997.tb00773.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
This preliminary experimental study demonstrates the potential usefulness of harmonic power Doppler imaging in producing Left ventricular myocardial opacification and demonstrating intramyocardial coronary vessels during contrast echocardiography using Levovist, a saccharide-based contrast agent. The contrast effect was most dramatic when a vasodilator such as dipyridamole or nitroglycerin was used in conjunction with contrast injections of Levovist. No significant myocardial opacification was noted with B-mode harmonic imaging alone.
引用
收藏
页码:631 / 635
页数:5
相关论文
共 9 条
  • [1] IMPROVED TRANSESOPHAGEAL ECHOCARDIOGRAPHIC ASSESSMENT OF SIGNIFICANT PROXIMAL HARROWING OF THE LEFT ANTERIOR DESCENDING AND LEFT CIRCUMFLEX CORONARY-ARTERIES USING ECHO CONTRAST ENHANCEMENT
    AGGARWAL, KK
    GATEWOOD, RP
    NANDA, NC
    CHOPRA, CKL
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1994, 73 (15) : 1131 - 1133
  • [2] Burns PN, 1996, CLIN RADIOL, V51, P50
  • [3] DelRio CG, 1996, ECHOCARDIOGR-J CARD, V13, P645
  • [4] INFLUENCE OF VARIOUS INSTRUMENT SETTINGS ON THE FLOW INFORMATION DERIVED FROM THE POWER MODE
    JAIN, SP
    FAN, PH
    PHILPOT, EF
    NANDA, NC
    AGGARWAL, KK
    MOOS, S
    YOGANATHAN, AP
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 1991, 17 (01) : 49 - 54
  • [5] Second harmonic imaging of an intravenously administered echocardiographic contrast agent - Visualization of coronary arteries and measurement of coronary blood flow
    Mulvagh, SL
    Foley, DA
    Aeschbacher, BC
    Klarich, KK
    Seward, JB
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1996, 27 (06) : 1519 - 1525
  • [6] AMPLITUDE INFORMATION FROM DOPPLER COLOR FLOW MAPPING SYSTEMS - A PRELIMINARY-STUDY OF THE POWER MODE
    PARRO, A
    PHILPOT, EF
    CZUWALA, PJ
    FAN, PH
    NANDA, NC
    CAPE, EG
    YOGANATHAN, AP
    HELMCKE, F
    FUJII, H
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1991, 18 (04) : 997 - 1003
  • [7] Improved myocardial contrast with second harmonic transient ultrasound response imaging in humans using intravenous perfluorocarbon-exposed sonicated dextrose albumin
    Porter, TR
    Xie, F
    Kricsfeld, D
    Armbruster, RW
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1996, 27 (06) : 1497 - 1501
  • [8] POWER DOPPLER US - A POTENTIALLY USEFUL ALTERNATIVE TO MEAN FREQUENCY-BASED COLOR DOPPLER US
    RUBIN, JM
    BUDE, RO
    CARSON, PL
    BREE, RL
    ADLER, RS
    [J]. RADIOLOGY, 1994, 190 (03) : 853 - 856
  • [9] Schlief R, 1996, CLIN RADIOL, V51, P5