ULTRASOUND VERSUS MRI IN COMMON FIBULAR NEUROPATHY

被引:21
作者
Bignotti, Bianca [1 ]
Assini, Andrea [2 ]
Signori, Alessio [1 ]
Martinoli, Carlo [1 ]
Tagliafico, Alberto [3 ]
机构
[1] Univ Genoa, Dept Hlth Sci DISSAL, Genoa, Italy
[2] Ente Osped Osped Galliera, Genoa, Italy
[3] Univ Genoa, Inst Anat, Dept Expt Med DIMES, Via LB Alberti 2, I-16132 Genoa, Italy
关键词
fibular nerve; magnetic resonance imaging; sensitivity; specificity; ultrasound; CROSS-SECTIONAL AREA; PERIPHERAL-NERVE PATHOLOGY; EXTREMITY NERVES; ULNAR NERVE; NEUROGRAPHY; RELIABILITY; PARAMETER; ELBOW; HEAD;
D O I
10.1002/mus.25418
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Introduction: We prospectively compared ultrasound (US) and MRI in patients with common fibular neuropathy. Methods: Forty adult patients with clinical suspicion of common fibular neuropathy and 40 healthy controls underwent both US and MRI. US and MRI datasets were randomized for prospective reading. Results: The overall sensitivity of US and MRI for diagnosing fibular neuropathy was 90% (95% confidence interval [CI], 79.7%-97.3%) and 87.5% (95% CI, 71.55%-93.1%), respectively. The overall specificity of US and MRI was 92% (95% CI, 77.45%-96.1%) and 85% (95% CI, 73.3%94.4%), respectively. The overall sensitivity and specificity of US combined with MRI were 94% (95% CI, 0.80%-0.99%) and 84% (95% CI, 0.70%-0.91%), respectively. Overall intra-and inter-observer agreements among 3 readers were 0.76% (95% CI, 0.62%-0.85%) and 0.74% (95% CI, 0.65%-0.81%). Conclusions: US diagnostic accuracy for common fibular neuropathy was slightly higher than that of MRI.
引用
收藏
页码:849 / 857
页数:9
相关论文
共 26 条
[21]   Reliability of side-to-side ultrasound cross-sectional area measurements of lower extremity nerves in healthy subjects [J].
Tagliafico, Alberto ;
Cadoni, Angela ;
Fisci, Erica ;
Bignotti, Bianca ;
Padua, Luca ;
Martinoli, Carlo .
MUSCLE & NERVE, 2012, 46 (05) :717-722
[22]   MR imaging of the brachial plexus: comparison between 1.5-T and 3-T MR imaging: preliminary experience [J].
Tagliafico, Alberto ;
Succio, Giulia ;
Neumaier, Carlo Emanuele ;
Serafini, Giovanni ;
Ghidara, Matteo ;
Calabrese, Massimo ;
Martinoli, Carlo .
SKELETAL RADIOLOGY, 2011, 40 (06) :717-724
[23]   NERVE DENSITY: A NEW PARAMETER TO EVALUATE PERIPHERAL NERVE PATHOLOGY ON ULTRASOUND. PRELIMINARY STUDY [J].
Tagliafico, Alberto ;
Tagliafico, Giulio ;
Martinoli, Carlo .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2010, 36 (10) :1588-1593
[24]   Fascicular Ratio: A New Parameter to Evaluate Peripheral Nerve Pathology on Magnetic Resonance Imaging A Feasibility Study on a 3T MRI System [J].
Tagliafico, Alberto S. ;
Tagliafico, Giulio .
MEDICINE, 2014, 93 (14)
[25]   Ultrasound and neurophysiological correlation in common fibular nerve conduction block at fibular head [J].
Tsukamoto, Hiroshi ;
Granata, Giuseppe ;
Coraci, Daniele ;
Paolasso, Ilaria ;
Padua, Luca .
CLINICAL NEUROPHYSIOLOGY, 2014, 125 (07) :1491-1495
[26]   Diagnostic value of high-resolution sonography in common fibular neuropathy at the fibular head [J].
Visser, Leo H. ;
Hens, Vanessa ;
Soethout, Maud ;
De Deugd-Maria, Violene ;
Pijnenburg, Jacqueline ;
Brekelmans, Geert J. F. .