Assessment of labor using a new type partogram compared to the classical Fisher partogram

被引:25
作者
Galazios, Georgios [1 ]
Tica, Vlad [2 ]
Vrachnis, Nikolaos [3 ]
Vlachos, Georgios [1 ]
Zervoudis, Stefanos [2 ]
Ceausu, Iuliana [2 ]
Trypsianis, Grigorios [1 ]
Zographou, Christos [1 ]
Tsikouras, Panagiotis [1 ]
机构
[1] Democritus Univ Thrace, Dept Obstet & Gynecol, Alexandroupolis 68100, Greece
[2] Univ Ovidius, Univ Reg Emergency Hosp, Dept Obstet & Gynecol, Bucharest, Romania
[3] Univ Athens, Sch Med, Dept Obstet & Gynecol 2, GR-11527 Athens, Greece
关键词
Fisher partogram; labor progress; new type partogram; CERVICAL DILATATION; OBSTRUCTED LABOR; GRAPHIC ANALYSIS; ACTION LINES; DESCENT;
D O I
10.3109/14767058.2014.905908
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Objective: To assess the quality of a new type partogram used to monitor labor. Methods: We compared efficacy using two types of partograms. The first was the classical WHO partogram (group A) and the second a new type in which we estimated and reported the sub of cervical dilatation and the position of the descending head (group B). Results: It was noted that there was a statistically significant decrease of the duration between the initiation of active phase of labor and the delivery time (dt1 + dt2 + dt3) (p < 0.001, A:mean: 318.4 +/- 10.4 min, B:246.56 +/- 8.28 min). Also observed was early initiation in the acceleration stage of the active phase in the first phase of labor (dt1) (p < 0.001, A: 108.73 +/- 5.29 min, B: 69.96 +/- 4.99 min), shorter duration of the acceleration stage of the active phase in the first phase of labor (dt2) (p50.001, A: 136.93 +/- 4.79 min, B: 91.89 +/- 4.04 min) and early initiation in the second phase of labor in women who were studied with the new partogram (B). Conclusion: The new partogram is more helpful in the recognition of the initiation of the acceleration stage during the active phase of labor and in the timely use of appropriate actions in order to achieve a safer delivery.
引用
收藏
页码:82 / 87
页数:6
相关论文
共 24 条
  • [1] Azandegbe N, 2004, Sante, V14, P251
  • [2] The partograph in daily practice: it's quality that matters
    Bosse, G
    Massawe, S
    Jahn, A
    [J]. INTERNATIONAL JOURNAL OF GYNECOLOGY & OBSTETRICS, 2002, 77 (03) : 243 - 244
  • [3] EFFECT OF PRESENTATION OF PARTOGRAM INFORMATION ON OBSTETRIC DECISION-MAKING
    CARTMILL, RSV
    THORNTON, JG
    [J]. LANCET, 1992, 339 (8808) : 1520 - 1522
  • [4] VALUE OF THE ALERT AND ACTION LINES ON THE PARTOGRAM
    DUJARDIN, B
    DESCHAMPHELEIRE, I
    SENE, H
    NDIAYE, F
    [J]. LANCET, 1992, 339 (8805) : 1336 - 1338
  • [5] Evaluation of health workers' training in use of the partogram
    Fatusi, A. O.
    Makinde, O. N.
    Adeyemi, A. B.
    Orji, E. O.
    Onwudiegwu, U.
    [J]. INTERNATIONAL JOURNAL OF GYNECOLOGY & OBSTETRICS, 2008, 100 (01) : 41 - 44
  • [6] GRAPHIC ANALYSIS OF LABOR
    FRIEDMAN, EA
    [J]. AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1978, 132 (07) : 822 - 823
  • [7] FRIEDMAN EA, 1978, AM J OBSTET GYNECOL, V132, P824, DOI 10.1016/S0002-9378(78)80018-0
  • [8] CERVIMETER FOR CONTINUOUS MEASUREMENT OF CERVICAL DILATATION IN LABOR - PRELIMINARY-RESULTS
    FRIEDMAN, EA
    [J]. BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 1978, 85 (08): : 638 - 638
  • [9] Obstructed labor: using better technologies to reduce mortality
    Hofmeyr, GJ
    [J]. INTERNATIONAL JOURNAL OF GYNECOLOGY & OBSTETRICS, 2004, 85 : S62 - S72
  • [10] PARTOGRAM OF A GRAND MULTIPARA - DIFFERENT DESCENT SLOPE COMPARED WITH AN ORDINARY PARTURIENT
    JUNTUNEN, K
    KIRKINEN, P
    [J]. JOURNAL OF PERINATAL MEDICINE, 1994, 22 (03) : 213 - 218