Experimental Verification of Rotor Demagnetization in a Fractional-Slot Concentrated-Winding PM Synchronous Machine Under Drive Fault Conditions

被引:24
作者
Choi, Gilsu [1 ]
Zhang, Yichao [2 ]
Jahns, T. M. [3 ]
机构
[1] Gen Motors Global Electrificat, Pontiac, MI 48340 USA
[2] GE Global Res, Niskayuna, NY 12309 USA
[3] Univ Wisconsin Madison, Dept Elect & Comp Engn, Madison, WI 53706 USA
关键词
Concentrated windings; demagnetization; interior permanent magnet; permanent magnet; single-phase asymmetrical short-circuit fault; three-phase symmetrical short-circuit fault; TEMPERATURE ESTIMATION; MAGNET; MOTOR;
D O I
10.1109/TIA.2017.2686806
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
This paper presents the results of experimental tests designed to verify analytical predictions of the rotor demagnetization characteristics of a 0.6 kW (cont.) 9-slot/6-pole fractional-slot concentrated winding (FSCW) interior permanent magnet (IPM) synchronous machine. The demagnetization characteristics of the rotor magnets in this commercially produced FSCW-IPM machine are measured using a test configuration that is designed to conduct multiple demagnetization tests on the same test machine under controlled temperature conditions. In this paper, finite-element (FE) predictions of the rotor demagnetization characteristics of the experimental machine during three-phase symmetrical short-circuit and single-phase asymmetrical short-circuit faults are presented. These results are compared with experimental test measurements of the postfault currents and the magnet flux density distribution following demagnetization, demonstrating very good agreement of many key features. These comparisons also confirm that 3-D effects and magnet material properties such as the magnet thermal coefficients have a significant impact on some details of the FE predictions of the machine's fault-mode response characteristics.
引用
收藏
页码:3467 / 3475
页数:9
相关论文
共 16 条
[1]  
[Anonymous], P INT C EL INF COMM
[2]   Investigation of Key Factors Influencing the Response of Permanent Magnet Synchronous Machines to Three-Phase Symmetrical Short-Circuit Faults [J].
Choi, Gilsu ;
Jahns, Thomas M. .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2016, 31 (04) :1488-1497
[3]   PM Synchronous Machine Drive Response to Asymmetrical Short-Circuit Faults [J].
Choi, Gilsu ;
Jahns, Thomas M. .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2016, 52 (03) :2176-2185
[4]   Permanent-Magnet Temperature Estimation in PMSMs Using Pulsating High-Frequency Current Injection [J].
Diaz Reigosa, David ;
Fernandez, Daniel ;
Yoshida, Hideo ;
Kato, Takashi ;
Briz, Fernando .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2015, 51 (04) :3159-3168
[5]   Magnet Temperature Estimation in Surface PM Machines During Six-Step Operation [J].
Diaz Reigosa, David ;
Briz, Fernando ;
Degner, Michael W. ;
Garcia, Pablo ;
Manuel Guerrero, Juan .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2012, 48 (06) :2353-2361
[6]  
Dow B. A., 2014, THESIS
[7]   Compensation of Speed Dependence in Sensorless Rotor Temperature Estimation for Permanent-Magnet Synchronous Motor [J].
Ganchev, Martin ;
Kral, Christian ;
Wolbank, Thomas M. .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2013, 49 (06) :2487-2495
[8]   Transient Analysis of Irreversible Demagnetization of Permanent-Magnet Brushless DC Motor With Interturn Fault Under the Operating State [J].
Kim, Kyung-Tae ;
Lee, Yoon-Seok ;
Hur, Jin .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2014, 50 (05) :3357-3364
[9]   Detecting rotor faults in low power permanent magnet synchronous machines [J].
le Roux, Wiehan ;
Harley, Ronald G. ;
Habetler, Thomas G. .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2007, 22 (01) :322-328
[10]  
Nair S. S., 2016, IEEE Trans. Magn., V52, P1