Stir Membrane Extraction: A Useful Approach for Liquid Sample Pretreatment

被引:56
作者
Alcudia-Leon, M. C. [1 ]
Lucena, R. [1 ]
Cardenas, S. [1 ]
Valcarcel, M. [1 ]
机构
[1] Univ Cordoba, Dept Analyt Chem, E-14071 Cordoba, Spain
关键词
BAR SORPTIVE EXTRACTION; MOLECULARLY IMPRINTED POLYMER; ASSISTED SOLVENT-EXTRACTION; PIEZOELECTRIC FLOW SENSOR; SOLID-PHASE EXTRACTION; BIOLOGICAL-FLUIDS; MICROEXTRACTION; CAFFEINE; WATER;
D O I
10.1021/ac9016192
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this paper, a novel extraction approach based on the use of a polymeric membrane as the extraction medium is described. For this aim, an original unit which allows the magnetic stirring of the membrane during the extraction process has been designed, optimized, and practically evaluated. On one hand, the main variables affecting the extraction process such as the unit design, the stirring rate, the extraction time, the sample volume, and the elution conditions were deeply studied. Once optimized, a model analytical problem, the determination of polycyclic aromatic hydrocarbons in water samples, was selected for practical evaluation of the stir membrane extraction procedure. The method was characterized on the basis of its linearity, precision, and limits of detection. The novel approach was sensitive and precise enough for the detection of the target analytes in the low nanogram per liter range using 25 mL of sample. In fact, limits of detection ranged from 0.8 ng/L (fluoranthene) to 7.6 ng/L (benzoanthracene) with relative standard deviations lower than 8%.
引用
收藏
页码:8957 / 8961
页数:5
相关论文
共 28 条
[21]   Electrokinetic migration across artificial liquid membranes - New concept for rapid sample preparation of biological fluids [J].
Pedersen-Bjergaard, S ;
Rasmussen, KE .
JOURNAL OF CHROMATOGRAPHY A, 2006, 1109 (02) :183-190
[22]   Liquid-liquid-liquid microextraction for sample preparation of biological fluids prior to capillary electrophoresis [J].
Pedersen-Bjergaard, S ;
Rasmussen, KE .
ANALYTICAL CHEMISTRY, 1999, 71 (14) :2650-2656
[23]   Drop-to-drop microextraction across a supported liquid membrane by an electrical field under stagnant conditions [J].
Petersen, Nickolaj Jacob ;
Jensen, Henrik ;
Hansen, Steen Honore ;
Rasmussen, Knut Einar ;
Pedersen-Bjergaard, Stig .
JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (09) :1496-1502
[24]   A Review of Stir Bar Sorptive Extraction [J].
Sanchez-Rojas, Fuensanta ;
Bosch-Ojeda, Catalina ;
Manuel Cano-Pavon, Jose .
CHROMATOGRAPHIA, 2009, 69 :S79-S94
[25]   Membrane-assisted solvent extraction of polychlorinated biphenyls in river water and other matrices combined with large volume injection-gas chromatography-mass spectrometric detection [J].
Schellin, M ;
Popp, P .
JOURNAL OF CHROMATOGRAPHY A, 2003, 1020 (02) :153-160
[26]   Feasibility of analyzing fine particulate matter in air using solid-phase extraction membranes and dynamic subcritical water extraction [J].
Tollback, Johanna ;
Bigata, Maria Blasco ;
Crescenzi, Carlo ;
Strom, Johan .
ANALYTICAL CHEMISTRY, 2008, 80 (09) :3159-3167
[27]   Films coated with molecular imprinted polymers for the selective stir bar sorption extraction of monocrotophos [J].
Zhu, Xiaolan ;
Cai, Jibao ;
Yang, Jun ;
Su, Qingde ;
Gao, Yun .
JOURNAL OF CHROMATOGRAPHY A, 2006, 1131 (1-2) :37-44
[28]   Automatic selective determination of caffeine in coffee and tea samples by using a supported liquid membrane-modified piezoelectric flow sensor with molecularly imprinted polymer [J].
Zougagh, M ;
Ríos, A ;
Valcárcel, M .
ANALYTICA CHIMICA ACTA, 2005, 539 (1-2) :117-124