Detection of inter-turn short-circuit on a Doubly Fed Induction Machine with D-Q axis representation

被引:2
作者
Bilal, Habachi [1 ,2 ,3 ]
Heraud, Nicolas [1 ,2 ]
Sambatra, Eric Jean Roy [3 ,4 ]
机构
[1] Univ Corsica, Corte, France
[2] CNRS, UMR 6134, Corte, France
[3] Univ Antsiranana, Antsiranana, Madagascar
[4] Higher Inst Techonol, Antsiranana, Madagascar
来源
2020 IEEE 61ST ANNUAL INTERNATIONAL SCIENTIFIC CONFERENCE ON POWER AND ELECTRICAL ENGINEERING OF RIGA TECHNICAL UNIVERSITY (RTUCON) | 2020年
关键词
Electrical fault detection; AC machines; Stators; Induction motors; Short-circuit currents; Fault detection; Fault diagnosis; Wind energy; Park's Vector Approach; SIGNATURE ANALYSIS; FAULT-DIAGNOSIS; MOTORS; MODEL;
D O I
10.1109/RTUCON51174.2020.9316591
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
In this paper, we propose to detect and quantify the fault of inter-turn short-circuit in the winding of a Doubly Fed Induction Machine (DFIM). This is essential to detect this type of defect at an early stage because this one can produce damage to the machine. So, we must be able firstly to detect the fault and secondly to quantify its severity. Our study responds to this and necessities a few calculi. We present in this paper a low sample time (1kHz), and we offer theoretical analysis with a model of our DFIM without fault, and a model included this fault. An analysis of the representation on the D-Q basis is done. After, we confirm these results through the exploitation of a platform which comprises a DFIM and a Data Acquisition (DAQ) system. The obtained results are rather hopeful.
引用
收藏
页数:4
相关论文
共 22 条
[1]   An improved stator winding fault tolerance architecture for vector control of induction motor: Theory and experiment [J].
Abdelmadjid, Gouichiche ;
Mohamed, Boucherit Seghir ;
Mohamed, Tadjine ;
Ahmed, Safa ;
Youcef, Messlem .
ELECTRIC POWER SYSTEMS RESEARCH, 2013, 104 :129-137
[2]   A current monitoring system for diagnosing electrical failures in induction motors [J].
Acosta, GG ;
Verucchi, C ;
Gelso, ER .
MECHANICAL SYSTEMS AND SIGNAL PROCESSING, 2006, 20 (04) :953-965
[3]   A review of induction motors signature analysis as a medium for faults detection [J].
Benbouzid, ME .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2000, 47 (05) :984-993
[4]   An efficient, simplified multiple-coupled circuit model of the induction motor aimed to simulate different types of stator faults [J].
Bouzid, M. ;
Champenois, G. .
MATHEMATICS AND COMPUTERS IN SIMULATION, 2013, 90 :98-115
[5]   Inter-turn stator winding fault diagnosis in three-phase induction motors, by Park's vector approach [J].
Cardoso, AJM ;
Cruz, SMA ;
Fonseca, DSB .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 1999, 14 (03) :595-598
[6]   Stator winding fault diagnosis in three-phase synchronous and asynchronous motors, by the Extended Park's Vector Approach [J].
Cruz, SMA ;
Cardoso, AJM .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2001, 37 (05) :1227-1233
[7]  
Douglas H, 2005, IEEE IND APPLIC SOC, P1097
[8]   Fault diagnosis in six-phase induction motor using a current trajectory mass center [J].
Foito, D. ;
Maia, J. ;
Fernao Pires, V. ;
Martins, J. F. .
MEASUREMENT, 2014, 51 :164-173
[9]  
Hamoudi A., 2017, INT J ELECT ENG INFO, V9, P42, DOI DOI 10.15676/IJEEI.2017.9.1.3
[10]   Detection and Location of Stator Winding Interturn Fault at Different Slots of DFIG [J].
He, Shuilong ;
Shen, Xuhong ;
Jiang, Zhansi .
IEEE ACCESS, 2019, 7 :89342-89353