An experimental study on the effect of the valve angle of counter-flow Ranque-Hilsch vortex tubes on thermal energy separation

被引:73
作者
Markal, Burak [1 ]
Aydin, Orhan [1 ]
Avci, Mete [1 ]
机构
[1] Karadeniz Tech Univ, TR-61080 Trabzon, Turkey
关键词
Ranque-Hilsch vortex tube; Energy separation; Conical valve; Helical generator;
D O I
10.1016/j.expthermflusci.2010.02.013
中图分类号
O414.1 [热力学];
学科分类号
摘要
An experimental study is conducted to investigate effects of the conical valve angle on thermal energy separation in a counter-flow vortex tube. A new geometry is designed for the cold end side, which is called 'helical swirl flow generator'. Combined and interactive effects of the helical length of the swirl flow generator, the ratio of the tube length to the tube inner diameter (LID), the inlet pressure and especially the angle of the conical valve on the performance of the vortex tube are comparatively investigated as a function of the cold mass fraction, y(c). Four different conical valves have been used with the angle of 30, 45 degrees, 60 degrees and 75 degrees. Finally, it is observed that the effect of the valve angle on the performance changes according to the value of L/D and, it has a weak influence on the system performance. (C) 2010 Elsevier Inc. All rights reserved.
引用
收藏
页码:966 / 971
页数:6
相关论文
共 8 条
  • [1] An experimental study on the design parameters of a counterflow vortex tube
    Aydin, Orhan
    Baki, Muzaffer
    [J]. ENERGY, 2006, 31 (14) : 2763 - 2772
  • [2] Balmer R. T., 1988, Transactions of the ASME. Journal of Fluids Engineering, V110, P161, DOI 10.1115/1.3243529
  • [3] Experimental investigation of the performance of a Ranque-Hilsch vortex tube with regard to a plug located at the hot outlet
    Dincer, K.
    Baskaya, S.
    Uysal, B. Z.
    Ucgul, I.
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2009, 32 (01): : 87 - 94
  • [4] Review of Ranque-Hilsch effects in vortex tubes
    Eiamsa-ard, Smith
    Promvonge, Ponglet
    [J]. RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2008, 12 (07) : 1822 - 1842
  • [5] Exergy analysis and performance of a counter flow Ranque-Hilsch vortex tube having various nozzle numbers at different inlet pressures of oxygen and air
    Kirmaci, Volkan
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2009, 32 (07): : 1626 - 1633
  • [6] An experimental investigation of the optimum geometry for the cold end orifice of a vortex tube
    Nimbalkar, Sachin U.
    Muller, Michael R.
    [J]. APPLIED THERMAL ENGINEERING, 2009, 29 (2-3) : 509 - 514
  • [7] Modification and experimental research on vortex tube
    Wu, Y. T.
    Ding, Y.
    Ji, Y. B.
    Ma, C. F.
    Ge, M. C.
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2007, 30 (06): : 1042 - 1049
  • [8] The effect of vortex angle on the efficiency of the Ranque-Hilsch vortex tube
    Xue, Yunpeng
    Arjomandi, Maziar
    [J]. EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2008, 33 (01) : 54 - 57