Effects of injection rate and dose on image quality in time-resolved magnetic resonance angiography (MRA) by using 1.0M contrast agents

被引:22
作者
Kramer, Harald
Michaely, Henrik J.
Requardt, Martin
Rohrer, Martin
Reeder, Scott
Reiser, Maximilian F.
Schoenberg, Stefan O.
机构
[1] Univ Munich, Univ Hosp Munich, D-81377 Munich, Germany
[2] Univ Munich, Univ Hosp Munich, Inst Clin Radiol, Munich, Germany
[3] Siemens Med Solut, Erlangen, Germany
[4] Schering AG, D-1000 Berlin, Germany
[5] Univ Wisconsin, Dept Radiol, Madison, WI 53706 USA
关键词
MRA; time-resolved contrast-enhanced MRA; injection rate;
D O I
10.1007/s00330-006-0493-x
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
In time-resolved MRA (TR MRA), injection parameters and contrast agent (CA) dose are important factors influencing image quality. In this study, three different injection schemes with different CA volumes were evaluated in 12 healthy volunteers. Injection rates between 0.2 and 0.8 ml/s were evaluated with CA volumes of 10 and 20 ml. To measure circulatory parameters, cine cardiac MRI was performed before each exam. Spatial resolution could be reduced to 2x1.4x2 mm(3), temporal resolution was 2.25 s/frame. To exclude signal saturation at high CA concentrations, a phantom with fixed CA concentrations was placed in the field of view. SNR was measured, and the area under the curve of the arterial signal of the different injection schemes was calculated. Results showed the largest diagnostic window at a relatively slow injection rate of 0.4 ml/s and a CA volume of 10 ml. Circulatory parameters have an important impact on CA arrival, so delay times have to be set depending on these parameters.
引用
收藏
页码:1394 / 1402
页数:9
相关论文
共 29 条
[21]   Pelvic and lower extremity arterial imaging: Diagnostic performance of three-dimensional contrast-enhanced MR angiography [J].
Ruehm, SG ;
Hany, TF ;
Pfammatter, T ;
Schneider, E ;
Ladd, M ;
Debatin, JF .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2000, 174 (04) :1127-1135
[22]   First clinical results in a study of contrast enhanced magnetic resonance angiography with the 1.0 molar gadobutrol in peripheral arterial occlusive disease -: Comparison to intraarterial DSA [J].
Schäfer, FKW ;
Schäfer, PJ ;
Jahnke, T ;
Walluscheck, K ;
Priebe, M ;
Hentsch, A ;
Heller, M ;
Brossmann, J .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2003, 175 (04) :556-564
[23]   Comprehensive MR angiography of the lower limbs:: a hybrid dual-bolus approach including the pedal arteries [J].
Schmitt, R ;
Coblenz, G ;
Cherevatyy, O ;
Brunner, H ;
Fröhner, S ;
Wedell, E ;
Karg, G ;
Christopoulos, G .
EUROPEAN RADIOLOGY, 2005, 15 (12) :2513-2524
[24]   High-spatial-resolution MR angiography of renal arteries with integrated parallel acquisitions: Comparison with digital subtraction angiography and US [J].
Schoenberg, SO ;
Rieger, J ;
Weber, CH ;
Michaely, HJ ;
Waggershauser, T ;
Ittrich, C ;
Dietrich, O ;
Reiser, MF .
RADIOLOGY, 2005, 235 (02) :687-698
[25]   Time-resolved three-dimensional contrast-enhanced MR angiography of the peripheral vessels [J].
Swan, JS ;
Carroll, TJ ;
Kennell, TW ;
Heisey, DM ;
Korosec, DM ;
Frayne, R ;
Mistretta, CA ;
Grist, TM .
RADIOLOGY, 2002, 225 (01) :43-52
[26]   k-t BLAST and k-t SENSE:: Dynamic MRI with high frame rate exploiting spatiotemporal correlations [J].
Tsao, J ;
Boesiger, P ;
Pruessmann, KP .
MAGNETIC RESONANCE IN MEDICINE, 2003, 50 (05) :1031-1042
[27]   Bolus arterial-venous transit in the lower extremity and venous contamination in bolus chase three-dimensional magnetic resonance angiography [J].
Wang, Y ;
Chen, CZ ;
Chabra, SG ;
Winchester, PA ;
Khilnani, NM ;
Watts, R ;
Bush, HL ;
Kent, KC ;
Prince, MR .
INVESTIGATIVE RADIOLOGY, 2002, 37 (08) :458-463
[28]   Recessed elliptical-centric view-ordering for contrast-enhanced 3D MR angiography of the carotid arteries [J].
Watts, R ;
Wang, Y ;
Redd, B ;
Winchester, PA ;
Kent, KC ;
Bush, HL ;
Prince, MR .
MAGNETIC RESONANCE IN MEDICINE, 2002, 48 (03) :419-424
[29]  
Ziyeh S, 2005, AM J NEURORADIOL, V26, P630