Periaortic Ventricular Tachycardias in Nonischemic Cardiomyopathy Substrate and Electrocardiographic Correlations

被引:8
作者
Nakajima, Ikutaro [1 ]
Narui, Ryohsuke [1 ]
Aboud, Asad A. [1 ]
Adeola, Oluwaseun [1 ]
McHugh, Julia [1 ]
Holmes, Benjamin [1 ]
Lugo, Ricardo [1 ]
Richardson, Travis D. [1 ]
Montgomery, Jay [1 ]
Shen, Sharon [1 ]
Kanagasundram, Arvindh [1 ]
Michaud, Gregory F. [1 ]
Stevenson, William G. [1 ]
机构
[1] Vanderbilt Univ, Dept Med, Cardiovasc Div, Med Ctr, Nashville, TN 37232 USA
关键词
aortic valve; cardiomyopathy; fibrosis; incidence; tachycardia; ventricular; RADIOFREQUENCY ABLATION; CATHETER ABLATION;
D O I
10.1161/CIRCEP.120.008887
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Periaortic fibrotic ventricular tachycardia (VT) substrate is common in nonischemic cardiomyopathy (NICM), often intramural, and difficult to ablate. We sought to better characterize normal and abnormal periaortic voltage map parameters and NICM periaortic VTs. Methods: In 15 patients without heart disease, the 5th percentile of endocardial voltage for increasing distance from the aortic valve ring was determined. In 53 consecutive patients with NICM (64 +/- 11 years; left ventricular ejection fraction 31 +/- 10%) undergoing ablation of recurrent VT, periaortic electrogram voltage and VT characteristics were analyzed. Results: In healthy patients, the fifth percentile of the bipolar voltage increased proportional to the distance from the aortic valve ring, from 1.0 mV at 1 cm to 1.5 mV at 1.5 cm; the corresponding unipolar voltage cutoffs were 5.0 and 7.5 mV. A total of 160 VTs were induced in 53 patients with NICM, of which 28 VTs in 20 patients had periaortic origins. Periaortic VTs were associated with similar periaortic bipolar voltage, but lower UVs consistent with intramural fibrosis as an important substrate. Periaortic VTs could be divided into left and right bundle branch block forms with mapping showing right septal and lateral exits. Left bundle branch block VTs were more often acutely abolished with ablation (100% versus 69%; P=0.034), but with a 23% incidence of heart block. Greater extent of low voltage was associated with more induced VTs and worse acute outcome. Conclusions: Adjusting voltage parameters based on distance from the aortic valve may improve definition of left ventricular outflow tract arrhythmia substrate. Periaortic VTs are common in NICM, often associated with intramural substrate and can be divided into left bundle branch block and right bundle branch block types associated with different ablation outcomes and risks.
引用
收藏
页码:185 / 196
页数:12
相关论文
共 20 条
[1]   Electroanatomic Substrate and Ablation Outcome for Suspected Epicardial Ventricular Tachycardia in Left Ventricular Nonischemic Cardiomyopathy [J].
Cano, Oscar ;
Hutchinson, Mathew ;
Lin, David ;
Garcia, Fermin ;
Zado, Erica ;
Bala, Rupa ;
Riley, Michael ;
Cooper, Joshua ;
Dixit, Sanjay ;
Gerstenfeld, Edward ;
Callans, David ;
Marchlinski, Francis E. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2009, 54 (09) :799-808
[2]   Anatomical correlates relevant to ablation above the semilunar valves for the cardiac electrophysiologist: a study of 603 hearts [J].
Gami, Apoor S. ;
Noheria, Amit ;
Lachman, Nirusha ;
Edwards, William D. ;
Friedman, Paul A. ;
Talreja, Deepak ;
Hammill, Stephen C. ;
Munger, Thomas M. ;
Packer, Douglas L. ;
Asirvatham, Samuel J. .
JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2011, 30 (01) :5-15
[3]   Isolated septal substrate for ventricular tachycardia in nonischemic dilated cardiomyopathy: Incidence, characterization, and implications [J].
Haqqani, Haris M. ;
Tschabrunn, Cory M. ;
Tzou, Wendy S. ;
Dixit, Sanjay ;
Cooper, Joshua M. ;
Riley, Michael P. ;
Lin, David ;
Hutchinson, Mathew D. ;
Garcia, Fermin C. ;
Bala, Rupa ;
Verdino, Ralph J. ;
Callans, David J. ;
Gerstenfeld, Edward P. ;
Zado, Erica S. ;
Marchlinski, Francis E. .
HEART RHYTHM, 2011, 8 (08) :1169-1176
[4]   Characterization of endocardial electrophysiological substrate in patients with nonischemic cardiomyopathy and monomorphic ventricular tachycardia [J].
Hsia, HH ;
Callans, DJ ;
Marchlinski, FE .
CIRCULATION, 2003, 108 (06) :704-710
[5]   Endocardial Unipolar Voltage Mapping to Detect Epicardial Ventricular Tachycardia Substrate in Patients With Nonischemic Left Ventricular Cardiomyopathy [J].
Hutchinson, Mathew D. ;
Gerstenfeld, Edward P. ;
Desjardins, Benoit ;
Bala, Rupa ;
Riley, Michael P. ;
Garcia, Fermin C. ;
Dixit, Sanjay ;
Lin, David ;
Tzou, Wendy S. ;
Cooper, Joshua M. ;
Verdino, Ralph J. ;
Callans, David J. ;
Marchlinski, Francis E. .
CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2011, 4 (01) :49-55
[6]   Successful simultaneous unipolar radiofrequency ablation of septal ventricular tachycardia using 2 ablation catheters [J].
Iyer, Vivek ;
Gambhir, Alok ;
Desai, Shalin P. ;
Garan, Hasan ;
Whang, William .
HEART RHYTHM, 2014, 11 (04) :710-713
[7]   Sustained Monomorphic Ventricular Tachycardia in Nonischemic Heart Disease Arrhythmia-Substrate Correlations That Inform the Approach to Ablation [J].
Kanagasundram, Arvindh ;
John, Roy M. ;
Stevenson, William G. .
CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2019, 12 (11)
[8]   Linear ablation lesions for control of unmappable ventricular tachycardia in patients with ischemic and nonischemic cardiomyopathy [J].
Marchlinski, FE ;
Callans, DJ ;
Gottlieb, CD ;
Zado, E .
CIRCULATION, 2000, 101 (11) :1288-1296
[9]  
Nagashima Koichi, 2014, Circ Arrhythm Electrophysiol, V7, P99, DOI 10.1161/CIRCEP.113.000870
[10]   Atrioventricular Block During Catheter Ablation for Ventricular Arrhythmias [J].
Nakamura, Tomofumi ;
Narui, Ryohsuke ;
Zheng, Qi ;
Yarmohammadi, Hirad ;
Tedrow, Usha B. ;
Koplan, Bruce A. ;
Michaud, Gregory F. ;
Stevenson, William G. ;
John, Roy M. .
JACC-CLINICAL ELECTROPHYSIOLOGY, 2019, 5 (01) :104-112