Immunomagnetic-electrochemiluminescent detection of Escherichia coli O157 and Salmonella typhimurium in foods and environmental water samples

被引:187
作者
Yu, H
Bruno, JG
机构
[1] USAF,ARMSTRONG LAB,EQC,ENVIRON DIRECTORATE,APPL RES ASSOCIATES,TYNDALL AFB,FL 32403
[2] USA,EDGEWOOD RES DEV & ENGN CTR,SYST RES LABS INC,ABERDEEN PROVING GROUND,MD 21010
关键词
D O I
10.1128/AEM.62.2.587-592.1996
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Hemorrhagic Escherichia coli O157:H7 strains and other virulent enteric pathogens can pose a serious health threat in tainted meats, poultry, and even drinking water. Traditional culture-based methods for assay of enteric pathogens in foods and water sources are relatively slow, and results can be ambiguous, Immunomagnetic separation (IMS) and detection methods have been investigated and appear promising for rapid bacterial assay of foods and environmental samples, In this work, a commercial sensor which combines IMS with electrochemiluminescence (ECL) detection is evaluated for detection of E, coli O157 and Salmonella typhimurium in foods and fomites, Results indicate that detection limits are in the range of 100 to 1,000 bacteria per mi in pristine buffer for E, coli O157 and S, typhimurium, respectively, or 1,000 to 2,000 bacteria per ml in food samples (depending on the sample) and that total processing and assay time is rapid (<1 h) even in food samples, An immunologic ''hook'' or high-antigen-concentration prozone effect was observed above 10(4) and 10(5) bacteria per ml for E. coli O157 and S. typhimurium, respectively, IMS was accomplished in milk, juices, serum, supernatant fluids from ground beef, finely minced chicken, and fish suspensions as well as several freshwater sources and followed by ECL assay, Some samples, especially fish, gave unexpectedly high background ECL, Conversely, low ECL intensity was observed in nonfat and 2% fat milk samples, which appeared to be related to binding or entrapment of the antibody-coated magnetic beads by particulates in the milk, as revealed by microscopy. Results of this evaluation suggest the feasibility of immunomagnetic-ECL methodology for rapid, sensitive, and facile preliminary screening of various foods and fomites for the presence of virulent enteric pathogens.
引用
收藏
页码:587 / 592
页数:6
相关论文
共 33 条
[1]   A MULTISTATE OUTBREAK OF ESCHERICHIA-COLI-O157-H7 ASSOCIATED BLOODY DIARRHEA AND HEMOLYTIC-UREMIC-SYNDROME FROM HAMBURGERS - THE WASHINGTON EXPERIENCE [J].
BELL, BP ;
GOLDOFT, M ;
GRIFFIN, PM ;
DAVIS, MA ;
GORDON, DC ;
TARR, PI ;
BARTLESON, CA ;
LEWIS, JH ;
BARRETT, TJ ;
WELLS, JG ;
BARON, R ;
KOBAYASHI, J .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1994, 272 (17) :1349-1353
[2]   AN OUTBREAK OF DIARRHEA AND HEMOLYTIC UREMIC SYNDROME FROM ESCHERICHIA-COLI O157-H7 IN FRESH-PRESSED APPLE CIDER [J].
BESSER, RE ;
LETT, SM ;
WEBER, JT ;
DOYLE, MP ;
BARRETT, TJ ;
WELLS, JG ;
GRIFFIN, PM .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1993, 269 (17) :2217-2220
[3]  
BLACKBURN GF, 1991, CLIN CHEM, V37, P1534
[4]  
COLLINS CH, 1989, MICROBIOLOGICAL METH, P133
[5]   ISOLATION OF ESCHERICHIA-COLI O157-H7 FROM RETAIL FRESH MEATS AND POULTRY [J].
DOYLE, MP ;
SCHOENI, JL .
APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 1987, 53 (10) :2394-2396
[6]   H7 ANTISERUM-SORBITOL FERMENTATION MEDIUM - A SINGLE TUBE SCREENING MEDIUM FOR DETECTING ESCHERICHIA-COLI O157-H7 ASSOCIATED WITH HEMORRHAGIC COLITIS [J].
FARMER, JJ ;
DAVIS, BR .
JOURNAL OF CLINICAL MICROBIOLOGY, 1985, 22 (04) :620-625
[7]   SENSITIVE DETECTION OF BIOTOXOIDS AND BACTERIAL-SPORES USING AN IMMUNOMAGNETIC ELECTROCHEMILUMINESCENCE SENSOR [J].
GATTOMENKING, DL ;
YU, H ;
BRUNO, JG ;
GOODE, MT ;
MILLER, M ;
ZULICH, AW .
BIOSENSORS & BIOELECTRONICS, 1995, 10 (6-7) :501-507
[8]   DETECTION OF SHIGELLA-DYSENTERIAE TYPE-1 AND SHIGELLA-FLEXNERI IN FECES BY IMMUNOMAGNETIC ISOLATION AND POLYMERASE CHAIN-REACTION [J].
ISLAM, D ;
LINDBERG, AA .
JOURNAL OF CLINICAL MICROBIOLOGY, 1992, 30 (11) :2801-2806
[9]   DETECTION OF PATHOGENIC YERSINIA-ENTEROCOLITICA IN FOODS AND WATER BY IMMUNOMAGNETIC SEPARATION, NESTED POLYMERASE CHAIN-REACTIONS, AND COLORIMETRIC DETECTION OF AMPLIFIED DNA [J].
KAPPERUD, G ;
VARDUND, T ;
SKJERVE, E ;
HORNES, E ;
MICHAELSEN, TE .
APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 1993, 59 (09) :2938-2944
[10]   EVALUATION OF USE OF TRIS(2,2'-BIPYRIDYL)RUTHENIUM(III) AS A CHEMILUMINESCENT REAGENT FOR QUANTITATION IN FLOWING STREAMS [J].
LEE, WY ;
NIEMAN, TA .
ANALYTICAL CHEMISTRY, 1995, 67 (11) :1789-1796