Miniaturized micromachined gas chromatography with universal and selective detectors for targeted volatile compounds analysis

被引:10
作者
Gras, Ronda [1 ,2 ,3 ]
Luong, Jim [1 ,2 ]
Shellie, Robert A. [3 ,4 ,5 ]
机构
[1] Dow Chem Canada ULC, Highway 15, Ft Saskatchewan, AB T8L 2P4, Canada
[2] Univ Tasmania, Australian Ctr Res Separat Sci ACROSS, Private Bag 75, Hobart, Tas 7001, Australia
[3] Univ Tasmania, ARC Training Ctr Portable Analyt Separat Technol, Private Bag 75, Hobart, Tas 7001, Australia
[4] Trajan Sci & Med, 7 Argent Pl, Ringwood, Vic 3134, Australia
[5] Deakin Univ, Sch Exercise & Nutr Sci, Ctr Adv Sensory Sci CASS, 221 Burwood Highway, Burwood, Vic 3125, Australia
基金
澳大利亚研究理事会;
关键词
Gas chromatography; VOC; Differential mobility spectrometry; Diode array detector; Thermal conductivity detector; DIODE-ARRAY DETECTION; DIFFERENTIAL MOBILITY SPECTROMETRY; PLANAR MICROFLUIDIC DEVICES;
D O I
10.1016/j.chroma.2018.08.064
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
An effective analytical strategy for targeted analysis of volatile organic compounds which combines two orthogonal separation mechanisms and multiple tunable detection in a compact transportable analytical system is introduced. This strategy uses a commercially available micromachined gas chromatograph comprising a micromachined on-board thermal conductivity detector. The chromatograph capability is enhanced by incorporating a modified diode array detector and a radio frequency modulated ion mobility spectrometry microfabricated electromechanical system. The analytical platform offers powerful detection capabilities of individual compounds and various classes of volatile organic compounds with improved provisional confirmatory capability. The transportable micromachined gas chromatograph employs field replaceable conventional capillary columns for the separation of analytes. The use of a silicon micromachined sample introduction device affords fast injection to minimize band broadening with fast chromatographic separation rendered in the order of minutes. Advantaged synergy also includes leveraging the resolving power of gas chromatography to minimize charge exchange in the ionization chamber of the differential mobility spectrometer for improved detector performance. Performance of this scalable and transportable analytical system is demonstrated with relevant volatile compounds such as acetaldehyde, acetone, carbon disulfide, benzene, and ethyl butyrate having a day-to-day variability less than 5% and with a high degree of reliability. (C) 2018 Elsevier B.V. All rights reserved.
引用
收藏
页码:151 / 155
页数:5
相关论文
共 33 条
[1]  
Bhardwaj S.K., 2016, Int. J. Anal. Bioanal. Chem, V6, P1
[2]  
Dettmer-Wilde K., 2014, PRACTICAL GAS CHROMA
[3]  
Eiceman G., 2005, ION MOB SPECTR
[4]  
Fix C. S., 2009, THESIS
[5]   Gas chromatography and diode array detection for the direct measurement of carbon disulfide in challenging matrices [J].
Gras, R. ;
Luong, J. ;
Shellie, R. A. .
ANALYTICAL METHODS, 2017, 9 (26) :3908-3913
[6]   Gas chromatography with simultaneous detection: Ultraviolet spectroscopy, flame ionization, and mass spectrometry [J].
Gras, Ronda ;
Luong, Jim ;
Haddad, Paul R. ;
Shellie, Robert A. .
JOURNAL OF CHROMATOGRAPHY A, 2018, 1563 :171-179
[7]   Gas chromatography with diode array detection in series with flame ionisation detection [J].
Gras, Ronda ;
Luong, Jim ;
Shellie, Robert A. .
JOURNAL OF CHROMATOGRAPHY A, 2017, 1500 :153-159
[8]   ULTRAVIOLET-VISIBLE DETECTION FOR CAPILLARY GAS-CHROMATOGRAPHY AND COMBINED ULTRAVIOLET MASS-SPECTROMETRY USING A REMOTE FLOW CELL [J].
HACKETT, M ;
WANG, HL ;
MILLER, GC ;
BORNHOP, DJ .
JOURNAL OF CHROMATOGRAPHY A, 1995, 695 (02) :243-257
[9]   Analysis of the gas phase of cigarette smoke by gas chromatography coupled with UV-diode array detection [J].
Hatzinikolaou, Dimitris G. ;
Lagesson, Verner ;
Stavridou, Anastasia J. ;
Pouli, Aristea E. ;
Lagesson-Andrasko, Ludmila ;
Stavrides, John C. .
ANALYTICAL CHEMISTRY, 2006, 78 (13) :4509-4516
[10]   Back-flushing and heart cut capillary gas chromatography using planar microfluidic Deans' switching for the separation of benzene and alkylbenzenes in industrial samples [J].
Jacobs, Matthew R. ;
Gras, Ronda ;
Nesterenko, Pavel N. ;
Luong, Jim ;
Shellie, Robert A. .
JOURNAL OF CHROMATOGRAPHY A, 2015, 1421 :123-128