Verifying the Melting Behavior in Single-Screw Plasticization Units Using a Novel Simulation Model and Experimental Method

被引:7
作者
Aigner, M. [1 ,2 ]
Praher, B. [3 ]
Kneidinger, C. [1 ,2 ]
Miethlinger, J. [1 ]
Steinbichler, G. [3 ]
机构
[1] Johannes Kepler Univ Linz, Inst Polymer Extrus & Compounding, A-4040 Linz, Austria
[2] Kompetenzzentrum Holz GmbH, Linz, Austria
[3] Johannes Kepler Univ Linz, Inst Polymer Inject Moulding & Proc Automat, A-4040 Linz, Austria
关键词
ULTRASOUND; EXTRUDERS; POLYMERS; PREDICTION; EXTRUSION;
D O I
10.3139/217.2949
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
We report on the development of a novel non-invasive ultrasonic measurement system for determining the melting behavior in a single-screw plasticization unit (35/22D) and on a modified drag-induced melt removal model that builds upon that by Tadmor and Gogos (2006). The solid bed to melt pool ratio is quantified using a non-invasive ultrasonic system based on reflection measurements. Automated analysis of the reflected pulses - measured at different axial positions along the barrel - allows the melting process to be monitored online. Our analysis of the delay section incorporates viscous dissipation into Tadmor's drag-induced melt removal model. We link temperature profile and melt film thickness via differential equations and consider viscous dissipation. By segmenting the delay section in the axial direction, the temperature dependency of the thermo-physical material properties is also considered. Using the melting behavior measured for different materials, we verified the mathematical model. Additionally, the effect of reduced screw length on the plasticization process, important for the injection molding process, was investigated.
引用
收藏
页码:624 / 634
页数:11
相关论文
共 29 条
  • [1] Binder W., 1999, THESIS LEOBEN
  • [2] BRONSTEIN IN, 1977, TASCHENBUCH MATH
  • [3] Brown E. C., 1999, P 15 ANN M POLYM PRO
  • [4] In line melt temperature measurement during real time ultrasound monitoring of single screw extrusion
    Brown, EC
    Olley, P
    Coates, PD
    [J]. PLASTICS RUBBER AND COMPOSITES, 2000, 29 (01) : 3 - 13
  • [5] Ultrasonic monitoring of nozzle and cavity during injection moulding
    Brown, EC
    Dawson, AJ
    Coates, PD
    [J]. JOURNAL OF REINFORCED PLASTICS AND COMPOSITES, 2002, 21 (05) : 441 - 450
  • [6] THEORETICAL MELTING MODEL FOR PLASTICATING EXTRUDERS
    DONOVAN, RC
    [J]. POLYMER ENGINEERING AND SCIENCE, 1971, 11 (03) : 247 - &
  • [7] MATHEMATICAL-MODELING OF MELTING OF POLYMERS IN A SINGLE-SCREW EXTRUDER
    ELBIRLI, B
    LINDT, JT
    GOTTGETREU, SR
    BABA, SM
    [J]. POLYMER ENGINEERING AND SCIENCE, 1984, 24 (12) : 988 - 999
  • [8] MATHEMATICAL-MODELING OF MELTING OF POLYMERS IN BARRIER-SCREW EXTRUDERS
    ELBIRLI, B
    LINDT, JT
    GOTTGETREU, SR
    BABA, SM
    [J]. POLYMER ENGINEERING AND SCIENCE, 1983, 23 (02) : 86 - 94
  • [9] Real-time monitoring of barrel thickness and barrel/screw separation using ultrasound
    Jen, CK
    Zun, ZG
    Kobayashi, M
    [J]. MEASUREMENT SCIENCE AND TECHNOLOGY, 2005, 16 (03) : 842 - 850
  • [10] Kim JG, 2004, KOREA-AUST RHEOL J, V16, P163