Three-dimensional analysis of delineation errors, setup errors, and organ motion during radiotherapy of bladder cancer

被引:135
作者
Meijer, GJ [1 ]
Rasch, C [1 ]
Remeijer, P [1 ]
Lebesque, JV [1 ]
机构
[1] Antoni Van Leeuwenhoek Huis, Netherlands Canc Inst, Dept Radiotherapy, Amsterdam, Netherlands
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2003年 / 55卷 / 05期
关键词
bladder cancer; margin widths; conformal radiotherapy;
D O I
10.1016/S0360-3016(02)04162-7
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To quantify in three dimensions the geometric uncertainties of bladder irradiation (i.e., uncertainties in target delineation, organ motion, and patient setup). Methods and Materials: Pelvic CT images were obtained for 10 male bladder cancer patients. Apart from the initial planning CT scan, three follow-up scans were made for each of the patients. The bladder volumes in the planning CT scan were outlined by seven radiation oncologists. One observer also delineated the bladder volumes in the follow-up scans. Two-dimensional scalar maps of the interobserver variation and organ motion of the bladder surfaces were constructed. The setup errors were derived from the portal imaging results of the pooled group of bladder and prostate patients. Results: All bladder volumes were consistently outlined by all observers. Generally small variations occurred (1.5-3 mm, 1 SD), although in 50% of the patients, larger discrepancies were observed in discriminating the bladder from the base of the prostate. Analysis of the portal imaging data showed setup errors of up to 3 mm (1 SD). Organ motion is the predominant geometric uncertainty in the radiotherapy process (5 min, 1 SD, at the cranial side of the bladder), although 9 of 10 patients were able to preserve a fairly reproducible bladder volume during the complete treatment course. Conclusion: Anisotropie margins between the clinical target volume and planning target volume are needed in conformal radiotherapy of the bladder. Especially at the cranial side of the bladder, larger margins are needed because of the impact of bladder shape variation. (C) 2003 Elsevier Science Inc.
引用
收藏
页码:1277 / 1287
页数:11
相关论文
共 26 条
  • [1] A VERIFICATION PROCEDURE TO IMPROVE PATIENT SET-UP ACCURACY USING PORTAL IMAGES
    BEL, A
    VANHERK, M
    BARTELINK, H
    LEBESQUE, JV
    [J]. RADIOTHERAPY AND ONCOLOGY, 1993, 29 (02) : 253 - 260
  • [2] Portable ultrasound determination of urinary residual volume
    Bent A.E.
    Nahhas D.E.
    McLennan M.T.
    [J]. International Urogynecology Journal, 1997, 8 (4) : 200 - 202
  • [3] AUTOMATIC VERIFICATION OF RADIATION-FIELD SHAPE USING DIGITAL PORTAL IMAGES
    BIJHOLD, J
    GILHUIJS, KGA
    VANHERK, M
    [J]. MEDICAL PHYSICS, 1992, 19 (04) : 1007 - 1014
  • [4] THE ACCURACY OF PORTABLE ULTRASOUND SCANNING IN THE MEASUREMENT OF RESIDUAL URINE VOLUME
    COOMBES, GM
    MILLARD, RJ
    [J]. JOURNAL OF UROLOGY, 1994, 152 (06) : 2083 - 2085
  • [5] A protocol for the reduction of systematic patient setup errors with minimal portal imaging workload
    De Boer, HCJ
    Heijmen, BJM
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2001, 50 (05): : 1350 - 1365
  • [6] THE RESULTS OF A SERIES OF 963 PATIENTS WITH TRANSITIONAL CELL-CARCINOMA OF THE URINARY-BLADDER PRIMARILY TREATED BY RADICAL MEGAVOLTAGE X-RAY THERAPY
    DUNCAN, W
    QUILTY, PM
    [J]. RADIOTHERAPY AND ONCOLOGY, 1986, 7 (04) : 299 - 310
  • [7] AN ALGORITHM FOR AUTOMATIC-ANALYSIS OF PORTAL IMAGES - CLINICAL-EVALUATION FOR PROSTATE TREATMENTS
    GILHUIJS, KGA
    ELGAYED, AAH
    VANHERK, M
    VIJLBRIEF, RE
    [J]. RADIOTHERAPY AND ONCOLOGY, 1993, 29 (02) : 261 - 268
  • [8] BLADDER CANCER - RESULTS OF RADIATION-THERAPY IN 384 PATIENTS
    GOFFINET, DR
    SCHNEIDER, MJ
    GLATSTEIN, EJ
    LUDWIG, H
    RAY, GR
    DUNNICK, NR
    BAGSHAW, MA
    [J]. RADIOLOGY, 1975, 117 (01) : 149 - 153
  • [9] Measurement of postvoid residual urine with portable transabdominal bladder ultrasound scanner and urethral catheterization
    Goode, PS
    Locher, JL
    Bryant, RL
    Roth, DL
    Burgio, KL
    [J]. INTERNATIONAL UROGYNECOLOGY JOURNAL, 2000, 11 (05) : 296 - 300
  • [10] SOLID TUMOR-MODELS FOR THE ASSESSMENT OF DIFFERENT TREATMENT MODALITIES .26. ESTIMATES OF CELL-SURVIVAL FROM TUMOR-GROWTH DELAY AFTER ALTERNATING RADIOTHERAPY AND CHEMOTHERAPY
    HOPKINS, HA
    LOONEY, WB
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1987, 13 (02): : 217 - 224