Radiation Exposure of Patient and Physician during Implantation and Upgrade of Cardiac Resynchronization Devices

被引:39
作者
Butter, Christian [1 ]
Schau, Thomas [1 ]
Meyhoefer, Juergen [1 ]
Neumann, Klaus [2 ]
Minden, Hans H. [1 ]
Engelhardt, Joerg [3 ]
机构
[1] Heart Ctr Brandenburg, Dept Cardiol, Bernau Berlin, Germany
[2] Heart Ctr Brandenburg, Dept Radiol, Bernau Berlin, Germany
[3] Landesanstalt Personendosimetrie & Strahlenschutz, Inst Dosimetry & Radiat Protect Fed State Mecklen, Berlin, Germany
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 2010年 / 33卷 / 08期
关键词
radiation exposure; cardiac resynchronization therapy and heart failure; HEART-FAILURE; THERAPY;
D O I
10.1111/j.1540-8159.2010.02765.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Methods: Dosimetry data were prospectively recorded in a series of 104 consecutive patients, who underwent resynchronization device implantation or upgrade in our cardiac catheterization laboratory. Five Chipstrate dosimeters were fixed to the patient's skin around the thorax (right and left paravertebral, right and left parasternal, and sternal positions), one dosimeter was attached to the forehead, and one to the pubis. The operator was equipped with one dosimeter on the forehead at eye level and a ring dosimeter was worn on the right hand. Results: Based on the maximum radiation dose of 9.2 mSv measured at the operator's hand in a single implantation session, it might be recommended to conservatively limit the number of implantations to four per month (an annual limit value of 500 mSv). At a mean dose of 1.2 mSv, this number can be increased sevenfold. Conclusion: In patients, incipient deterministic radiation effects can theoretically be observed at dose area product > 400 Gy center dot cm2, a dose applied in 2.9% of CRT implantation procedures. Special follow-up programs are considered necessary for these patients and for operators, as the latter may be exposed over many years given the unknown long-term impact of chronic radiation exposure and the nature of current complex electrophysiology and device procedures. (PACE 2010; 1003-1012).
引用
收藏
页码:1003 / 1012
页数:10
相关论文
共 29 条
[1]   Cardiac resynchronization in chronic heart failure [J].
Abraham, WT ;
Fisher, WG ;
Smith, AL ;
Delurgio, DB ;
Leon, AR ;
Loh, E ;
Kocovic, DZ ;
Packer, M ;
Clavell, AL ;
Hayes, DL ;
Ellestad, M ;
Messenger, J ;
Trupp, RJ ;
Underwood, J ;
Pickering, F ;
Truex, C ;
McAtee, P .
NEW ENGLAND JOURNAL OF MEDICINE, 2002, 346 (24) :1845-1853
[2]   Acute chromosomal DNA damage in human lymphocytes after radiation exposure in invasive cardiovascular procedures [J].
Andreassi, Maria Grazia ;
Cioppa, Angelo ;
Manfredi, Samantha ;
Palmieri, Cataldo ;
Botto, Nicoletta ;
Picano, Eugenio .
EUROPEAN HEART JOURNAL, 2007, 28 (18) :2195-2199
[3]  
[Anonymous], 1996, OFFICIAL J EUROPEA L, V159, p0001
[4]   Visualization of coronary arteries in patients after childhood Kawasaki syndrome: value of multidetector CT and MR imaging in comparison to conventional coronary catheterization [J].
Arnold, Raoul ;
Ley, Sebastian ;
Ley-Zaporozhan, Julia ;
Eichhorn, Joachim ;
Schenk, Jens-Peter ;
Ulmer, Herbert ;
Kauczor, Hans-Ulrich .
PEDIATRIC RADIOLOGY, 2007, 37 (10) :998-1006
[5]   Cardiac-resynchronization therapy with or without an implantable defibrillator in advanced chronic heart failure [J].
Bristow, MR ;
Saxon, LA ;
Boehmer, J ;
Krueger, S ;
Kass, DA ;
De Marco, T ;
Carson, P ;
DiCarlo, L ;
DeMets, D ;
White, BG ;
DeVries, DW ;
Feldman, AM .
NEW ENGLAND JOURNAL OF MEDICINE, 2004, 350 (21) :2140-2150
[6]   Effects of multisite biventricular pacing in patients with heart failure and intraventricular conduction delay. [J].
Cazeau, S ;
Leclercq, C ;
Lavergne, T ;
Walker, S ;
Varma, C ;
Linde, C ;
Garrigue, S ;
Kappenberger, L ;
Haywood, GA ;
Santini, M ;
Bailleul, C ;
Daubert, JC .
NEW ENGLAND JOURNAL OF MEDICINE, 2001, 344 (12) :873-880
[7]  
CENGIZ E, 2005, J AM COLL CARDIOL, V46, P2258
[8]   Skin entrance radiation dose in an interventional radiology procedure [J].
Chu, Robert Y. L. ;
Thomas, George ;
Maqbool, Feroz .
HEALTH PHYSICS, 2006, 91 (01) :41-46
[9]   ELECTROPHYSIOLOGICAL LABORATORY, ELECTROPHYSIOLOGIST-IMPLANTED, NONTHORACOTOMY-IMPLANTABLE CARDIOVERTER/DEFIBRILLATORS [J].
FITZPATRICK, AP ;
LESH, MD ;
EPSTEIN, LM ;
LEE, RJ ;
SIU, A ;
MERRICK, S ;
GRIFFIN, JC ;
SCHEINMAN, MM .
CIRCULATION, 1994, 89 (06) :2503-2508
[10]   All patients with heart failure and intraventricular conduction defect or dyssynchrony should not receive cardiac resynchronization therapy [J].
Greenberg, Barry ;
Mehra, Mandeep R. .
CIRCULATION, 2006, 114 (24) :2685-2690