Fit for Purpose Experimental Designs and Analyses in Chemical Development

被引:2
作者
Bacchi, Sergio [1 ]
Yahyah, Mohammad [2 ]
Carangio, Antonella [3 ]
Ribecai, Arianna [1 ]
Oliveros, Maria Concepcion Cerrato [1 ]
机构
[1] GlaxoSmithKline Med Res Ctr, Synthet Chem, Chem Dev, I-37135 Verona, Italy
[2] GlaxoSmithKline Inc, Stat Sci, Stevenage SG1 2NY, Herts, England
[3] GlaxoSmithKline Inc, Synthet Chem, Chem Dev, Stevenage SG1 2NY, Herts, England
关键词
PLS;
D O I
10.1021/op900286r
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
Classical experimental designs have been used as configurations of choice at GlaxoSmithKline within Chemical Development in establishing robust products and processes while achieving other goals such as reduction of cost, waste, process investigation times and most importantly improved quality. Occasionally, as in this paper, these first intent designs have been proved to be unworkable through irregularly shaped experimental regions induced through chemistry constraints. To achieve optimum efficiency, a fit for purpose computer-aided D-Optimal Design in considering the reduction of cyclic imides to amines has been investigated here, proving to be an invaluable additional tool in applying the appropriate design at the relevant time. In addition, partial least squares (PLS) analyses has been explored with a view of simultaneously modelling the responses whilst primarily identifying those factors having the largest impact across the responses of interest (quantity of reducing agent and solvent, temperature, and time). This combined with process analytical technology (PAT) through online IR monitoring has facilitated part of this cyclic process of investigations using scientific and business judgment.
引用
收藏
页码:332 / 338
页数:7
相关论文
共 23 条
  • [1] [Anonymous], 1980, Infrared Characteristic Group Frequencies
  • [2] [Anonymous], 2004, PAT FRAM INN PHARM
  • [3] Brown H. C., 1972, US Patent, Patent No. 3634277
  • [4] BURKARDT ER, 2000, Patent No. 6048985
  • [5] d Souza M.V. N., 2006, Appl. Organomet. Chem, V20, P798
  • [6] MULTIVARIATE-ANALYSIS OF AQUATIC TOXICITY DATA WITH PLS
    ERIKSSON, L
    HERMENS, JLM
    JOHANSSON, E
    VERHAAR, HJM
    WOLD, S
    [J]. AQUATIC SCIENCES, 1995, 57 (03) : 217 - 241
  • [7] HERBERT CB, 1972, Patent No. 19720111
  • [8] HINZ DC, 2004, PAT J PROCESS ANAL T, V1, P16
  • [9] On-line mid-IR spectroscopy as a real-time approach in monitoring hydrogenation reactions
    Marziano, I
    Sharp, DCA
    Dunn, PJ
    Hailey, PA
    [J]. ORGANIC PROCESS RESEARCH & DEVELOPMENT, 2000, 4 (05) : 357 - 361
  • [10] MYAKISHEV KG, 1984, I NEORG KHIM NOVOSIB, V29, P912